Intra- and inter-rater reliability of the rate of force development of hip abductor muscles measured by hand-held dynamometer

被引:14
|
作者
Takeda, Kazuya [1 ,2 ]
Tanabe, Shigeo [3 ]
Koyama, Soichiro [3 ]
Nagai, Tomoko [1 ]
Sakurai, Hiroaki [3 ]
Kanada, Yoshikiyo [3 ]
Shomoto, Koji [2 ]
机构
[1] Kawamura Hosp, Dept Rehabil, Gifu, Japan
[2] Kio Univ, Grad Sch Hlth Sci, Nara, Japan
[3] Fujita Hlth Univ, Sch Hlth Sci, Fac Rehabil, Toyoake, Aichi, Japan
关键词
Hand-held dynamometer; hip abductor muscles; rate of force development; reliability; FUNCTIONAL ELECTRICAL-STIMULATION; TOTAL KNEE ARTHROPLASTY; STRENGTH; GAIT; ASSOCIATION; PERFORMANCE; PEOPLE;
D O I
10.1080/1091367X.2017.1365078
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
The aim of this study was to clarify the intra- and inter-rater reliability of the rate of force development in hip abductor muscle force measurements using a hand-held dynamometer. Thirty healthy adults were separately assessed by two independent raters on two separate days. Rate of force development was calculated from the slope of the force-time curve that was divided into four time intervals (50, 100, 200, and 300 ms). The highest values of the three trials were used for statistical analysis. The intra-class correlation coefficient with a 95% confidence interval, standard error of measurement, and minimal detectable change at the 95% confidence level were calculated for each interval. For assessment of systematic error, Bland-Altman analysis was used. The results indicated that intra-and inter-rater reliability of the highest values at all intervals were sufficient (intra-class correlation coefficient >.7). The Bland-Altman analysis did not show systematic error in either reliability measure.
引用
收藏
页码:19 / 24
页数:6
相关论文
共 50 条
  • [1] The intra- and inter-rater reliability of manual muscle testing and a hand-held dynamometer for measuring wrist strength in symptomatic and asymptomatic subjects
    Toemen, Angela
    Dalton, Sarah
    Sandford, Fiona
    HAND THERAPY, 2011, 16 (03) : 67 - 74
  • [2] Inter-rater Reliability And Accuracy Of Hand-held Dynamometer Testing For Isometric Arm Flexion
    Powell, Garret
    Turner, Meredith
    Mayhew, Jerry L.
    Koch, Alexander J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 297 - 298
  • [3] Intra- and Inter-Rater Reliability of Strength Measurements Using a Pull Hand-Held Dynamometer Fixed to the Examiner's Body and Comparison with Push Dynamometry
    Gonzalez-Rosalen, Javier
    Benitez-Martinez, Josep Carles
    Medina-Mirapeix, Francesc
    Cuerda-Del Pino, Alba
    Cervello, Antonio
    Martin-San Agustin, Rodrigo
    DIAGNOSTICS, 2021, 11 (07)
  • [4] INTRA- AND INTER-RATER RELIABILITY OF HYOID DISPLACEMENT MEASURED BY ULTRASOUND
    Macrae, Phoebe
    Huckabee, M.
    Doeltgen, S.
    Jones, R.
    DYSPHAGIA, 2009, 24 (04) : 482 - 483
  • [5] Intra- and inter-rater reliability for analysis of hyoid displacement measured with sonography
    Macrae, Phoebe R.
    Doeltgen, Sebastian H.
    Jones, Richard D.
    Huckabee, Maggie-Lee
    JOURNAL OF CLINICAL ULTRASOUND, 2012, 40 (02) : 74 - 78
  • [6] Intra-Rater and Inter-Rater Reliability of Hand-Held Dynamometry for Shoulder Strength Assessment in Circus Arts Students
    Ganderton, Charlotte
    Kerr, Bonnie
    King, Matthew
    Lenssen, Ross
    Warby, Sarah
    Munro, David
    Watson, Lyn
    Balster, Simon
    Han, Jia
    Tirosh, Oren
    MEDICAL PROBLEMS OF PERFORMING ARTISTS, 2021, 36 (02) : 88 - 102
  • [7] Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis
    Vaz, Gilvan Ferreira
    Freire, Felipe Florencio
    Goncalves, Henrique Mansur M.
    de Aviz, Marcus Alexandre Brito M.
    Martins, Wagner Rodrigues M.
    Durigan, Joao Luiz Quagliotti M.
    PLOS ONE, 2023, 18 (06):
  • [8] The intra- and inter-rater reliabilities of lower extremity muscle strength assessment of healthy adults using a hand held dynamometer
    Kim, Seong-Gil
    Lee, Yun-Seob
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (06) : 1799 - 1801
  • [9] Reliability and validity of eccentric strength measurement of the shoulder abductor muscles using a hand-held dynamometer
    Karabay, Damla
    Yesilyaprak, Sevgi Sevi
    Picak, Gonca Sahiner
    PHYSICAL THERAPY IN SPORT, 2020, 43 : 52 - 57
  • [10] Reliability intra and inter-rater of a handheld dynamometer in COPD patients
    Sentanin, Anna
    Facio, Carina de Araujo
    Di Lorenzo, Valeria Amorim Pires
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50