Intra- and interobserver variability in the diagnosis of GERD by real-time MRI

被引:13
|
作者
Hosseini, Ali Seif Amir [1 ]
Beham, Alexander [3 ]
Uhlig, Johannes [1 ]
Streit, Ulrike [1 ]
Uhlig, Annemarie [2 ]
Ellenrieder, Volker [4 ]
Joseph, Arun A. [5 ]
Voit, Dirk [5 ]
Frahm, Jens [5 ,6 ]
Uecker, Martin [1 ,6 ]
Lotz, Joachim [1 ,6 ]
Biggemann, Lorenz [1 ]
机构
[1] Univ Med Ctr, Dept Diagnost & Intervent Radiol, D-37073 Gottingen, Germany
[2] Univ Med Ctr, Dept Urol, Gottingen, Germany
[3] Univ Med Ctr, Dept Gen Visceral & Paediat Surg, Gottingen, Germany
[4] Univ Med Ctr, Dept Gastroenterol & Gastrointestinal Oncol, Gottingen, Germany
[5] Max Planck Inst Biophys Chem, Biomed NMR Forsch GmbH, Gottingen, Germany
[6] DZHK German Ctr Cardiovasc Res, Partner Site Gottingen, Gottingen, Germany
关键词
Real-time MRI; Gastroesophageal reflux disease (GERD); His-angle; GASTROESOPHAGEAL-REFLUX DISEASE; ESOPHAGITIS; RADIOLOGY; POPULATION; MANAGEMENT; AGREEMENT; SYMPTOMS;
D O I
10.1016/j.ejrad.2018.04.029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to assess the reproducibility of functional and anatomical parameters of swallowing events as determined by real-time MRI at 40 ms temporal resolution (25 frames per second). Twenty-three consecutive patients with gastroesophageal reflux disease (GERD) underwent real-time MRI of the gastroesophageal junction at 3.0 T. Real-time MRI was based on highly undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by regularized nonlinear inversion (NLINV). MRI movies visualized the esophageal transport of a pineapple juice bolus, its passage through the gastroesophageal junction and functional responses during a Valsalva maneuver. His-angle, sphincter position, sphincter length and sphincter transit time were assessed by two radiologists. Interobserver and intraobserver intraclass correlation coefficients (ICC) were evaluated and Bland-Altman plots were constructed to assess the observer agreement. Interobserver agreement was excellent for sphincter transit time (ICC = 0.92), His-angle (ICC = 0.93), His-angle during Valsalva maneuver (ICC = 0.91) and sphincter-to-diaphragm distance (ICC = 0.98). Sphincter length and oesophageal diameter showed good interobserver agreement (ICC = 0.62 and ICC = 0.70). Intraobserver agreement was good for sphincter length (ICC = 0.80) and excellent for sphincter transit time, His-angle and His-angle during Valsalva maneuver, sphincter-to-diaphragm distance, and esophageal diameter (ICC = 0.91; ICC = 0.97; ICC = 0.97; ICC = 0.998; ICC = 0.93). All functional parameters of the gastroesophageal junction had good to excellent reproducibility. Visual assessment of Bland Altman plots did not reveal any systematic interobserver bias. In conclusion, the visualization of swallowing events by realtime MRI has a high potential for clinical application in gastroesophageal reflux disease.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 50 条
  • [1] Intra- and interobserver variability of MRI prostate volume measurements
    Bonilla, J
    Stoner, E
    Grino, P
    Binkowitz, B
    Taylor, A
    [J]. PROSTATE, 1997, 31 (02): : 98 - 102
  • [2] Intra- and Interobserver Variability in the Assessment of Ampullary Dysplasia
    Allard, Felicia
    Goldsmith, Jeffrey
    Ayata, Gamze
    Brown, Larry
    Challies, Tracy
    Najarian, Robert
    Nasser, Imad
    Wang, Helen
    Yee, Eric
    [J]. LABORATORY INVESTIGATION, 2016, 96 : 439A - 439A
  • [3] Intra- and interobserver variability in fetal ultrasound measurements
    Sarris, I.
    Ioannou, C.
    Chamberlain, P.
    Ohuma, E.
    Roseman, F.
    Hoch, L.
    Altman, D. G.
    Papageorghiou, A. T.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (03) : 266 - 273
  • [4] Intra- and Interobserver Variability in the Assessment of Ampullary Dysplasia
    Allard, Felicia
    Goldsmith, Jeffrey
    Ayala, Gamze
    Brown, Larry
    Challies, Tracy
    Najarian, Robert
    Nasser, Imad
    Wang, Helen
    Yee, Eric
    [J]. MODERN PATHOLOGY, 2016, 29 : 439A - 439A
  • [5] Intra- and Interobserver Variability in CT Measurements in Oncology
    McErlean, Aoife
    Panicek, David M.
    Zabor, Emily C.
    Moskowitz, Chaya S.
    Bitar, Richard
    Motzer, Robert J.
    Hricak, Hedvig
    Ginsberg, Michelle S.
    [J]. RADIOLOGY, 2013, 269 (02) : 450 - 458
  • [6] FREEHAND REAL-TIME ELASTOGRAPHY: IMPACT OF SCANNING PARAMETERS ON IMAGE QUALITY AND IN VITRO INTRA- AND INTEROBSERVER VALIDATIONS
    Havre, Roald Flesland
    Elde, Erlend
    Gilja, Odd Helge
    Odegaard, Svein
    Eide, Geir Egil
    Matre, Knut
    Nesje, Lars Birger
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (10): : 1638 - 1650
  • [7] Intravascular ultrasound and stent implantation: Intra- and interobserver variability
    Blessing, E
    Hausmann, D
    Sturm, M
    Mugge, A
    Amende, I
    [J]. HEART, 1996, 75 (05) : 224 - 224
  • [8] Intra- and interobserver agreement of rectal cancer staging with MRI
    Kilickap, Gulsum
    Dolek, Betul Akdal
    Ercan, Karabekir
    [J]. ACTA RADIOLOGICA, 2023, 64 (05) : 1747 - 1754
  • [9] Laser vs ultrasound biometry—a study of intra- and interobserver variability
    S Goel
    C Chua
    M Butcher
    C A Jones
    P Bagga
    S Kotta
    [J]. Eye, 2004, 18 : 514 - 518
  • [10] Anthropometric Landmarking for Diagnosis of Cranial Deformities: Validation of an Automatic Approach and Comparison with Intra- and Interobserver Variability
    Helena R. Torres
    Pedro Morais
    Anne Fritze
    Wolfram Burkhardt
    Maxi Kaufmann
    Bruno Oliveira
    Fernando Veloso
    Gabriele Hahn
    Mario Rüdiger
    Jaime C. Fonseca
    João L. Vilaça
    [J]. Annals of Biomedical Engineering, 2022, 50 : 1022 - 1037