A CMOS Wearable Infrared Light Intensity Digital Converter for Monitoring Unplanned Self-Extubation of Patients

被引:4
|
作者
Chiang, Cheng-Ta [1 ]
Liu, Kang-Yu [1 ]
机构
[1] Natl Chiayi Univ, Dept Elect Engn, Chiayi 600, Taiwan
关键词
Infrared; wearable; converter; IoT; unplanned extubation; medical institution; SIGMA-DELTA ADC; HAND; SENSOR; WRIST;
D O I
10.1109/JSEN.2019.2910184
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a complementary metal oxide semiconductor wearable infrared (IR) light intensity digital converter for monitoring the unplanned self-extubation of patients. The proposed converter could process the IR light intensity without limitations of the field-of-view and is immune to ambient optical noise. Furthermore, the output of the proposed converter can be easily transmitted to Internet of things devices. The sensing area of a monolithic photodiode was 120 x 120 mu m(2), and the complete size of the chip was 1.21 x 2.04 mm(2). The measured distance between an IR light source and the proposed converter was 15-29 cm, and the measured signal-to-noise-distortion ratio was corresponding to 80.9-74.9 dB. Finally, an experiment was conducted for monitoring the unplanned self-extubation of patients. The results indicate that the proposed chip is suitable for usage in medical institutions.
引用
收藏
页码:6430 / 6436
页数:7
相关论文
共 5 条
  • [1] An Infrared Photocurrent Intensity to Continuous-Time Incremental Sigma-Delta Modulator for Monitoring Unplanned Self-Extubation of Patients in Medical Institution
    Chiang, Cheng-Ta
    Liu, Kang-Yu
    PROCEEDINGS OF 4TH IEEE INTERNATIONAL CONFERENCE ON APPLIED SYSTEM INNOVATION 2018 ( IEEE ICASI 2018 ), 2018, : 939 - 942
  • [2] A new device to prevent unplanned endotracheal self-extubation in mechanically ventilated patients.
    Lin, Chen-Chun
    Wu, Hsiu-Li
    Chen, Szu-Yin
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [3] Risk factors associated with unplanned endotracheal self-extubation of hospitalized intubated patients: a 3-year retrospective case-control study
    Chang, Li-Chun
    Liu, Pei-Fen
    Huang, Yu-Lu
    Yang, Sien-Sing
    Chang, Wen-Yin
    APPLIED NURSING RESEARCH, 2011, 24 (03) : 188 - 192
  • [4] A CMOS Ultraviolet (UV) Light Intensity to Duty Cycle Converter with Calibration Circuits for Monitoring Environmental UV Light Applications
    Chiang, Cheng-Ta
    Chang, Chia-Ming
    Chang, Chih-Chieh
    2017 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2017, : 56 - 60
  • [5] A 119dB Dynamic Range Charge Counting Light-to-Digital Converter For Wearable PPG/NIRS Monitoring Applications
    Lin, Qiuyang
    Xu, Jiawei
    Song, Shuang
    Breeschoten, Arjan
    Konijnenburg, Mario
    Van Hoof, Chris
    Tavernier, Filip
    Van Helleputte, Nick
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2020, 14 (04) : 800 - 810