Determination of silicon, manganese and magnesium in cast iron by atomic emission spectrometry

被引:0
|
作者
Zhou, Y [1 ]
Shao, W [1 ]
Tang, M [1 ]
机构
[1] San Xia Univ, Dept Chem Engn, Yichang 443003, Peoples R China
关键词
atomic emission spectrometry; cast iron; silicon; manganese; magnesium;
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A spectrograph with high voltage spark source, once pre-burned and continuous photography was used for the quantitative determination of Silicon, Manganese and Magnesium in cast iron. The experimental conditions were optimized including the control of pre-burning time, plate moving rate, slit height of the blackness measuring, the selection of electrode material, the distance between the electrodes, shape of the electrode and the diminution of interferences. The determination range of contents (omega/omega) are 0.010% - 0.090% for Mg, 1.50% - 3.50% for Si and 0.40% - 1.10% for Mn. The relative standard deviations are 10.4%, 1.9% and 3.0% for Mg,Si, and Mn, respectively.
引用
收藏
页码:470 / 471