Influence of air content and vibration time on frost resistance of air entrained concrete

被引:3
|
作者
Zheng, Xiuhua [1 ]
Ge, Yong [1 ]
Yuan, Jie [1 ]
机构
[1] Harbin Inst Technol, Sch Transportat Sci & Engn, Harbin, Peoples R China
来源
ADVANCED PAVEMENT RESEARCH | 2014年 / 857卷
关键词
frost resistance; air-entraining agent; air void structure; vibration time; air spacing factor; AGENT;
D O I
10.4028/www.scientific.net/AMR.857.110
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air-entraining agent turely is one of the necessary compositions of the high durability concrete. The influence of air content and vibration time on the frost resistance of concrete was researched, and air void characteristics of hardened concrete was analysed. The results showed that the air contents could reduce the compressive strengthof hardened concrete excessively, but it made the spacing factor reduce obviously and significantly improve the frost resistance of concrete.The air voids with different structure in concrete were realized by vibration time. It was found that the air void structure and the frost resistance properties were influenced by the vibration time largely. The optimized vibration time is 30s, the appropriate vibration time is 20s similar to 30s, no more than 35s.
引用
收藏
页码:110 / 115
页数:6
相关论文
共 50 条
  • [1] Effect of entrained air on frost resistance of porous concrete
    Nakamura, T.
    Horiguchi, T.
    Shimura, K.
    [J]. Proceedings of the 6th International Symposium on Cement & Concrete and CANMET/ACI International Symposium on Concrete Technology for Sustainable Development, Vols 1 and 2, 2006, : 902 - 907
  • [2] The Flexural Strength and Frost Resistance of Air Entrained Concrete
    Zheng, Xiuhua
    Li, Qinfei
    Yuan, Jie
    Ge, Yong
    [J]. ADVANCES IN INTELLIGENT TRANSPORTATION SYSTEM AND TECHNOLOGY, 2012, 5 : 364 - 369
  • [3] Effect of High Frequency Vibration on Pore Parameters and Frost Resistance of Air Entrained Concrete
    Zhang Yan-cong
    Gao Ling-ling
    [J]. CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 1680 - +
  • [4] Influence of Coarse Aggregate Concentration on the Frost Resistance of Non-Air-Entrained Concrete
    Cai, Jiwei
    Wang, Donghui
    Xu, Gelong
    Tian, Qing
    Guo, Shaokun
    [J]. JOURNAL OF ENGINEERING, 2022, 2022
  • [5] Air void structure in relation to the frost resistance of air-entrained concrete by with microspheres
    Wawrzenczyk, Jerzy
    Molendowska, Agnieszka
    [J]. CEMENT WAPNO BETON, 2011, 16 (05): : 278 - +
  • [6] Using strain to evaluate influence of air content on frost resistance of concrete
    Du, Peng
    Yao, Yan
    Wang, Ling
    Xu, Dongyu
    Zhou, Zonghui
    Sun, Jian
    Cheng, Xin
    [J]. COLD REGIONS SCIENCE AND TECHNOLOGY, 2019, 157 : 21 - 29
  • [7] Frost Resistance of Non Air Entrained Self-Compacting Concrete
    Kristjansson, Thordur I.
    Wallevik, Olafur H.
    [J]. NORDIC CONCRETE RESEARCH, 2014, 50 (02): : 391 - 394
  • [8] Study of frost resistance on air-entrained concrete in sulfated medium
    Yong, G
    Jie, Y
    Yang, WC
    Zhang, BS
    [J]. ENVIRONMENTAL ECOLOGY AND TECHNOLOGY OF CONCRETE, 2006, 302-303 : 125 - 130
  • [9] The Influence of Atmospheric Pressure on Air Content and Pore Structure of Air-entrained Concrete
    李扬
    WANG Zhendi
    王玲
    [J]. Journal of Wuhan University of Technology(Materials Science), 2019, 34 (06) : 1365 - 1370
  • [10] The Influence of Atmospheric Pressure on Air Content and Pore Structure of Air-entrained Concrete
    Li Yang
    Wang Zhendi
    Wang Ling
    [J]. JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2019, 34 (06): : 1365 - 1370