Influence of pump noise on the health of fish in a large pumping station

被引:5
|
作者
Zhang, Fan [1 ]
Zhu, Lu-feng [1 ]
Shi, Xiao-tao [2 ]
Chen, Ke [1 ]
Appiah, Desmond [1 ]
Yuan, Shou-qi [1 ]
Zhang, Jin-feng [1 ]
机构
[1] Jiangsu Univ, Natl Res Ctr Pumps, Zhenjiang 212013, Jiangsu, Peoples R China
[2] China Three Gorges Univ, Hubei Int Sci & Technol Cooperat Base Fish Passag, Yichang 443002, Peoples R China
基金
中国国家自然科学基金;
关键词
Fish; numerical analysis; axial flow pump; ACTRAN; hearing impairment; VALIDATION;
D O I
10.1007/s42241-022-0033-4
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The axial flow pump, characteristic of a large flow, is widely used in pumping stations of hydraulic engineering. However, the internal noise of the axial-flow pump of a high sound pressure level is notable, with a great influence on the fishing livelihood. At present, the studies of the impact of the noise on fish are mainly focused on the explosion, the offshore wind power plant, the ship and other fields, with little attention on the noise generated by the pumping station. This paper applies the combination of the computational fluid dynamics and the Actran to study the sound pressure level distribution in the high-noise area inside the axial-flow pump and the noise distribution in the downstream areas of the pumping station. Extensive comparisons are made of the hearing threshold and the hearing damage threshold of fish, and it is revealed that the noise inside the axial-flow pump exceeds the hearing damage threshold of fish, which could lead to the hearing damage of over-pumped fish. Further, the noises emitted from the pumping station to the downstream are beyond the fish hearing threshold and will also have a significant impact on the fish around the pumping station. This study can provide a reference for studying the impact of the noise generated by various large-scale water transfer projects on fish.
引用
收藏
页码:522 / 531
页数:10
相关论文
共 50 条
  • [1] Influence of pump noise on the health of fish in a large pumping station
    Fan Zhang
    Lu-feng Zhu
    Xiao-tao Shi
    Ke Chen
    Desmond Appiah
    Shou-qi Yuan
    Jin-feng Zhang
    [J]. Journal of Hydrodynamics, 2022, 34 : 522 - 531
  • [2] The Influence of Geometric Parameters of Pump Installation on the Hydraulic Performance of a Prefabricated Pumping Station
    Zhang, Bowen
    Cheng, Li
    Xu, Chunlei
    Wang, Mo
    [J]. ENERGIES, 2021, 14 (04)
  • [3] Research on efficient pump device with new type volute passage of large pumping station
    Li, Yanjun
    Yan, Hongqin
    Ge, Qiang
    Chen, Songshan
    Yan, Dengfeng
    [J]. Shuili Fadian Xuebao/Journal of Hydroelectric Engineering, 2009, 28 (06): : 200 - 205
  • [4] Adjusting Frequency of Pump Blade Angles and Optimal Operation for Large Pumping Station System
    Feng, Xiaoli
    Qiu, Baoyun
    [J]. ADVANCES IN MECHANICAL ENGINEERING, 2013,
  • [5] Study on fish damage mechanism of the large flow rate centrifugal pump in hydraulic engineering pump station
    Zhu, Lufeng
    Zhang, Fan
    Xu, Zhengxuan
    Yuan, Shouqi
    Zulu, Bernard
    Hong, Qiuhong
    [J]. Physics of Fluids, 2024, 36 (11)
  • [6] Design and implementation of remote status supervision platform of water pump set in large pumping station
    Zou, Hongmei
    Tang, Hongru
    Yan, Guofei
    [J]. Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2010, 40 (SUPPL. 1): : 348 - 352
  • [7] Further Consideration of Teaching System on Pump and Pumping Station
    Liu, Hongyuan
    Guo, Min
    Zhou, Lingxue
    [J]. 2012 INTERNATIONAL CONFERENCE ON EDUCATION REFORM AND MANAGEMENT INNOVATION (ERMI 2012), VOL 5, 2013, : 165 - 170
  • [8] RELIABILITY OF PUMP SET FOR EXAMPLE THE PUMPING STATION OF WASTE
    Niekrawiec, Dariusz
    [J]. RYNEK ENERGII, 2010, (02): : 103 - 107
  • [9] Weight Determined Method of Large Pumping Station Engineering Health Comprehensive Diagnosis
    Cao Qiulin
    Li Bei
    [J]. 2011 INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS AND NEURAL COMPUTING (FSNC 2011), VOL V, 2011, : 287 - 290
  • [10] Weight Determined Method of Large Pumping Station Engineering Health Comprehensive Diagnosis
    Cao Qiulin
    Li Bei
    [J]. 2011 AASRI CONFERENCE ON APPLIED INFORMATION TECHNOLOGY (AASRI-AIT 2011), VOL 3, 2011, : 287 - 290