Improving the spectral resolution and spectral fitting of 1H MRSI data from human calf muscle by the SPREAD technique

被引:30
|
作者
Dong, Zhengchao [1 ,2 ]
Zhang, Yudong [1 ,2 ]
Liu, Feng [1 ,2 ]
Duan, Yunsuo [1 ,2 ]
Kangarlu, Alayar [1 ,2 ]
Peterson, Bradley S. [1 ]
机构
[1] Columbia Univ Coll Phys & Surg, Dept Psychiat, New York, NY 10032 USA
[2] New York State Psychiat Inst & Hosp, New York, NY 10032 USA
关键词
magnetic resonance spectroscopic imaging; spectral resolution; spectral fitting; calf muscle; MAGNETIC-RESONANCE-SPECTROSCOPY; SKELETAL-MUSCLE; PROTON MR; INTRAMYOCELLULAR LIPIDS; 7; T; DECONVOLUTION; SHIFT; SEPARATION; SIGNALS; INVIVO;
D O I
10.1002/nbm.3193
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Proton magnetic resonance spectroscopic imaging (H-1 MRSI) has been used for the in vivo measurement of intramyocellular lipids (IMCLs) in human calf muscle for almost two decades, but the low spectral resolution between extramyocellular lipids (EMCLs) and IMCLs, partially caused by the magnetic field inhomogeneity, has hindered the accuracy of spectral fitting. The purpose of this paper was to enhance the spectral resolution of H-1 MRSI data from human calf muscle using the SPREAD (spectral resolution amelioration by deconvolution) technique and to assess the influence of improved spectral resolution on the accuracy of spectral fitting and on in vivo measurement of IMCLs. We acquired MRI and H-1 MRSI data from calf muscles of three healthy volunteers. We reconstructed spectral lineshapes of the H-1 MRSI data based on field maps and used the lineshapes to deconvolve the measured MRS spectra, thereby eliminating the line broadening caused by field inhomogeneities and improving the spectral resolution of the H-1 MRSI data. We employed Monte Carlo (MC) simulations with 200 noise realizations to measure the variations of spectral fitting parameters and used an F-test to evaluate the significance of the differences of the variations between the spectra before SPREAD and after SPREAD. We also used Cramer-Rao lower bounds (CRLBs) to assess the improvements of spectral fitting after SPREAD. The use of SPREAD enhanced the separation between EMCL and IMCL peaks in H-1 MRSI spectra from human calf muscle. MC simulations and F-tests showed that the use of SPREAD significantly reduced the standard deviations of the estimated IMCL peak areas (p < 10(-8)), and the CRLBs were strongly reduced (by similar to 37%). Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:1325 / 1332
页数:8
相关论文
共 50 条
  • [1] Spectral assignments and reference data -: 1H and 13C NMR spectral assignment of androstane derivatives
    Fuente, A
    Reyes, M
    Alvarez, YM
    Ruiz, JA
    Vélez, H
    Viñas-Bravo, O
    Montiel-Smith, S
    Meza-Reyes, S
    Sandoval-Ramírez, J
    MAGNETIC RESONANCE IN CHEMISTRY, 2005, 43 (08) : 676 - 678
  • [2] 1H and 13C NMR spectral data of new saponins from Cordia piauhiensis
    Santos, Renata P.
    Silveira, Edilberto R.
    Uchoa, Daniel Esdras de A.
    Pessoa, Otilia Deusdenia L.
    Viana, Francisco Arnaldo
    Braz Filho, Raimundo
    MAGNETIC RESONANCE IN CHEMISTRY, 2007, 45 (08) : 692 - 694
  • [3] 1H and 13C NMR Spectral Data of Neolignans Isolated from Piper Species
    do Nascimento Marinho, Rosiane Ferreira
    Peres Angrisani, Bianca Roberta
    Macedo, Arthur Ladeira
    Moreira, Davyson de Lima
    Rocha Ribeiro, Carlos Magno
    Alves Vasconcelos, Thatyana Rocha
    Valverde, Alessandra Leda
    CURRENT ORGANIC CHEMISTRY, 2020, 24 (14) : 1527 - 1554
  • [4] Spectral assignments and reference data -: Complete assignments of 1H and 13C NMR spectral data for benzylidenebenzyl butyrolactone lignans
    da Silva, R
    Pedersoli, S
    Lacerda, V
    Donate, PM
    de Albuquerque, S
    Bastos, JK
    Araújo, ALSD
    Silva, MLAE
    MAGNETIC RESONANCE IN CHEMISTRY, 2005, 43 (11) : 966 - 969
  • [5] HIGH-RESOLUTION H-1-NMR SPECTRAL SIGNATURE FROM HUMAN ATHEROMA
    PEARLMAN, JD
    ZAJICEK, J
    MERICKEL, MB
    CARMAN, CS
    AYERS, CR
    BROOKEMAN, JR
    BROWN, MF
    MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (03) : 262 - 279
  • [6] Batch statistical processing of 1H NMR-derived urinary spectral data
    Antti, H
    Bollard, ME
    Ebbels, T
    Keun, H
    Lindon, JC
    Nicholson, JK
    Holmes, E
    JOURNAL OF CHEMOMETRICS, 2002, 16 (8-10) : 461 - 468
  • [7] High-resolution mapping of human brain metabolites by free induction decay 1H MRSI at 7?T
    Bogner, W.
    Gruber, S.
    Trattnig, S.
    Chmelik, M.
    NMR IN BIOMEDICINE, 2012, 25 (06) : 873 - 882
  • [8] High resolution 1H and 13C NMR and mass spectral studies of substituted dipyridylpyridazine
    El-Qisairi, AK
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2002, 16 (01): : 37 - 41
  • [9] Compressed sensing for high-resolution nonlipid suppressed 1H FID MRSI of the human brain at 9.4T
    Nassirpour, Sahar
    Chang, Paul
    Avdievitch, Nikolai
    Henning, Anke
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2311 - 2325
  • [10] Quantification of cross-relaxation in downfield 1H MRS at 7 T in human calf muscle
    Swago, Sophia
    Elliott, Mark A.
    Nanga, Ravi Prakash Reddy
    Wilson, Neil E.
    Cember, Abigail
    Reddy, Ravinder
    Witschey, Walter R.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (01) : 11 - 20