Clinical impact of digital and conventional PET control databases for semi-quantitative analysis of brain 18F-FDG digital PET scans

被引:6
|
作者
Mairal, Elise [1 ,2 ]
Doyen, Matthieu [1 ,2 ,3 ]
Rivasseau-Jonveaux, Therese [4 ]
Malaplate, Catherine [5 ]
Guedj, Eric [6 ]
Verger, Antoine [1 ,2 ,3 ]
机构
[1] Univ Lorraine, Dept Nucl Med, CHRU Nancy, Rue Morvan, F-54500 Vandoeuvre Les Nancy, France
[2] Univ Lorraine, Nancyclotep Imaging Platform, CHRU Nancy, Rue Morvan, F-54500 Vandoeuvre Les Nancy, France
[3] Univ Lorraine, INSERM U1254, IADI, F-54000 Nancy, France
[4] Univ Lorraine, CHRU Nancy, Dept Geriatr, Clin Memory & Res Ctr,2LPN EA 7489, F-54000 Nancy, France
[5] Univ Lorraine, CHRU Nancy, Dept Biochem Mol Biol & Nutr, F-54000 Nancy, France
[6] Aix Marseille Univ, Timone Hosp, AP HM, CNRS,Cent Marseille,Inst Fresnel,CERIMED,Nucl Med, Marseille, France
关键词
POSITRON-EMISSION-TOMOGRAPHY; FDG-PET; DIFFERENTIAL-DIAGNOSIS; ALZHEIMER-DISEASE; VISUAL ASSESSMENT; DEMENTIA; VALIDATION; TEMPLATE; SYSTEM;
D O I
10.1186/s13550-020-00733-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Digital PET cameras markedly improve sensitivity and spatial resolution of brain F-18-FDG PET images compared to conventional cameras. Our study aimed to assess whether specific control databases are required to improve the diagnostic performance of these recent advances. Methods We retrospectively selected two groups of subjects, twenty-seven Alzheimer's Disease (AD) patients and twenty-two healthy control (HC) subjects. All subjects underwent a brain F-18-FDG PET on a digital camera (Vereos, Philips (R)). These two group (AD and HC) are compared, using a Semi-Quantitative Analysis (SQA), to two age and sex matched controls acquired with a digital PET/CT (Vereos, Philips (R)) or a conventional PET/CT (Biograph 6, Siemens (R)) camera, at group and individual levels. Moreover, individual visual interpretation of SPM T-maps was provided for the positive diagnosis of AD by 3 experienced raters. Results At group level, SQA using digital controls detected more marked hypometabolic areas in AD (+ 116 cm(3) at p < 0.001 uncorrected for the voxel, corrected for the cluster) than SQA using conventional controls. At the individual level, the accuracy of SQA for discriminating AD using digital controls was higher than SQA using conventional controls (86% vs. 80%, p < 0.01, at p < 0.005 uncorrected for the voxel, corrected for the cluster), with higher sensitivity (89% vs. 78%) and similar specificity (82% vs. 82%). These results were confirmed by visual analysis (accuracies of 84% and 82% for digital and conventional controls respectively, p = 0.01). Conclusion There is an urgent need to establish specific digital PET control databases for SQA of brain F-18-FDG PET images as such databases improve the accuracy of AD diagnosis.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Clinical impact of digital and conventional PET control databases for semi-quantitative analysis of brain 18F-FDG digital PET scans
    Elise Mairal
    Matthieu Doyen
    Thérèse Rivasseau-Jonveaux
    Catherine Malaplate
    Eric Guedj
    Antoine Verger
    [J]. EJNMMI Research, 10
  • [2] Clinical impact of digital vs conventional healthy control databases for semi-quantitative analysis of brain 18F-FDG PET scans
    Doyen, M.
    Mairal, E.
    Jonveaux, T. Rivasseau
    Malaplate-Armand, C.
    Roch, V.
    Karcher, G.
    Guedj, E.
    Verger, A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S164 - S165
  • [3] Comparison of semi-quantitative parameters of 18F-FDG digital PET/CT and simultaneous PET/MRI in lymphoma patients
    Panperee, Pimlapat
    Thongdonpua, Supachoke
    Jantarato, Attapon
    Promteangtrong, Chetsadaporn
    Kunawudhi, Anchisa
    Kiatkittikul, Peerapon
    Siripongsatian, Dheeratama
    Keeratipiriyakul, Jiratthakorn
    Konggasame, Onanong
    Chotipanich, Chanisa
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [4] Clinical value of semi-quantitative analysis of 18F-FDG PET/CT in the diagnosis of Lung lesions
    Wang, R.
    Zhang, J.
    Liao, X.
    Fan, Y.
    Zhang, X.
    Liu, M.
    Kang, L.
    Wang, Y.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S457 - S457
  • [5] The pons as reference region for intensity normalization in semi-quantitative analysis of brain 18FDG PET: application to metabolic changes related to ageing in conventional and digital control databases
    A. Verger
    M. Doyen
    J. Y. Campion
    Eric Guedj
    [J]. EJNMMI Research, 11
  • [6] The pons as reference region for intensity normalization in semi-quantitative analysis of brain 18FDG PET: application to metabolic changes related to ageing in conventional and digital control databases
    Verger, A.
    Doyen, M.
    Campion, J. Y.
    Guedj, Eric
    [J]. EJNMMI RESEARCH, 2021, 11 (01)
  • [7] Impact of respiratory motion on 18F-FDG PET radiomics stability: Clinical evaluation with a digital PET scanner
    Chen, Yu-Hung
    Kan, Kuo-Yi
    Liu, Shu-Hsin
    Lin, Hsin-Hon
    Lue, Kun-Han
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (12):
  • [8] Clinical evaluation of reconstruction and acquisition time for pediatric 18F-FDG brain PET using digital PET/CT
    Shkumat, Nicholas A.
    Vali, Reza
    Shammas, Amer
    [J]. PEDIATRIC RADIOLOGY, 2020, 50 (07) : 966 - 972
  • [9] Clinical evaluation of reconstruction and acquisition time for pediatric 18F-FDG brain PET using digital PET/CT
    Nicholas A. Shkumat
    Reza Vali
    Amer Shammas
    [J]. Pediatric Radiology, 2020, 50 : 966 - 972
  • [10] The effect of reconstruction algorithms on semi-quantitative measurements in 18F-FDG PET/CT imaging
    Ozulker, Filiz
    Babacan, Gunduzalp Bugrahan
    Cengiz, Safiya
    Ozulker, Tamer
    [J]. HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2024, 27 (02) : 85 - 92