A Cross-Flow Turbine Turned With Non-Uniform Flow Velocity On The Cooling Tower

被引:1
|
作者
Santoso, Budi [1 ]
Tjahjana, Dominicus Danardono Dwi Prija [1 ]
Picaso, Genta Praha [1 ]
机构
[1] Sebelas Maret Univ, Fac Engn, Dept Mech Engn, Surakarta 57126, Indonesia
关键词
D O I
10.1063/1.5098224
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The exhaust air from the cooling tower has a maximum velocity of 9 m/s and is more constant than the natural wind. This exhaust air stream has a non-uniform velocity profile. The cross-flow wind turbine with 400 mm diameter and 380 mm long are placed above the cooling tower to produce work. Variations in the blade angle and the blade radius of the turbine are tested to determine the effect on the resulting power and turbine performance on the graph of coefficient power (CP) versus tip speed ratio (TSR). The result shows that cross-flow wind turbine with blade angle 45 degrees has higher power than the other blade angle on all radius variation. The cross-flow wind turbine with a 60 mm radius of the blade on 45 degrees blade angle has the highest performance with 2.47 Watt maximum power on 4.31 m/s wind velocity, and Cp is 0.41 on 0.76 TSR.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] CROSS-FLOW COOLING TOWER
    FRITZSCHE, P
    [J]. BRENNSTOFF-WARME-KRAFT, 1968, 20 (02): : 61 - +
  • [2] Assessment of an agricultural spray in a non-uniform cross-flow
    Farooq, Muhammad
    Balachandar, Ram
    Wolf, Thomas
    [J]. Transactions of the American Society of Agricultural Engineers, 2001, 44 (06): : 1455 - 1460
  • [3] Numerical model of a cross-flow heat exchanger with non-uniform flow of media
    Hanuszkiewicz-Drapala, Malgorzata
    Bury, Tomasz
    Widziewicz, Katarzyna
    [J]. JOURNAL OF POWER TECHNOLOGIES, 2013, 93 (05): : 295 - 302
  • [4] Simulation of a cross-flow cooling tower performance
    Fisenko, S. P.
    Brin, A. A.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (15-16) : 3216 - 3223
  • [5] IMPROVE CROSS-FLOW COOLING-TOWER OPERATION
    BURGER, R
    [J]. HYDROCARBON PROCESSING, 1989, 68 (12): : 51 - 52
  • [6] Thermal and experimental analysis of cross-flow closed cooling tower
    Hassab, M. A.
    Mansour, M. Khamis
    Sadek, L. A.
    Qassem, M. A.
    [J]. ALEXANDRIA ENGINEERING JOURNAL, 2023, 69 : 739 - 746
  • [7] Performance of non-uniform tidal turbine arrays in uniform flow
    Bonar P.A.J.
    Adcock T.A.A.
    Venugopal V.
    Borthwick A.G.L.
    [J]. Journal of Ocean Engineering and Marine Energy, 2018, 4 (3) : 231 - 241
  • [8] Stability of fluid flow in a porous medium with uniform cross-flow and velocity slip
    Kandavelu, Vasuki
    Tlau, Lalrinpuia
    [J]. CHINESE JOURNAL OF PHYSICS, 2024, 90 : 528 - 541
  • [9] NON-UNIFORM SOURCE TERM MODEL FOR FILM COOLING WITH THE INTERNAL CROSS FLOW
    Zhang, Zhen
    Chen, Ziyu
    Su, Xinrong
    Yuan, Xin
    [J]. PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 7B, PT I, 2020,
  • [10] SUCCESSIVE GRAPHICAL METHOD OF DESIGN OF A CROSS-FLOW COOLING-TOWER
    INAZUMI, H
    KAGEYAMA, S
    [J]. CHEMICAL ENGINEERING SCIENCE, 1975, 30 (07) : 717 - 721