The Effect of the Digital Manufacturing Technique, Preparation Taper, and Cement Type on the Retention of Aged Anterior Provisional Crowns: An In Vitro Study

被引:2
|
作者
Lunkad, Honey [1 ]
Sayed, Mohammed E. [1 ]
Alhazmi, Abdullah Essa [2 ]
Alwadani, Bandar [2 ]
Shafei, Ameen Marwei [2 ]
Ayoub, Muath Naji [2 ]
Shabi, Maan Mohammed A. [2 ]
Mesawa, Sara Ahmad [2 ]
Abdulfatah, Basmah Alhassan [3 ]
Alqarni, Hatem [4 ,5 ]
Alqahtani, Saeed M. [6 ]
Alamoudi, Ahmed [7 ]
Almalki, Mohammed Salman [8 ]
Jethlia, Ankur [9 ]
Jain, Saurabh [1 ]
机构
[1] Jazan Univ, Coll Dent, Dept Prosthet Dent Sci, Jazan 45142, Saudi Arabia
[2] Jazan Univ, Coll Dent, Jazan 45142, Saudi Arabia
[3] Minist Hlth, Jazan 45142, Saudi Arabia
[4] King Saud Bin Abdulaziz Univ Hlth Sci, Coll Dent, Restorat & Prosthet Dent Sci Dept, Natl Guard Hlth Affairs, Riyadh 14611, Saudi Arabia
[5] King Abdullah Int Med Res Ctr, Natl Guard Hlth Affairs, Riyadh 14611, Saudi Arabia
[6] King Khalid Univ, Coll Dent, Dept Prosthet Dent, Abha 62529, Saudi Arabia
[7] Fac Dent King Abdulaziz Univ, 7Department Oral Biol, Jeddah 22254, Saudi Arabia
[8] Minist Hlth, Dept Prosthodont, Abha, Saudi Arabia
[9] Jazan Univ, Coll Dent, Dept Maxillofacial Surg & Diag Sci, Diag Div, Jazan 45142, Saudi Arabia
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 24期
关键词
provisional crowns; 3D printing; CAD; CAM milling; taper; temporary cement; retention; CONVERGENCE ANGLE; INTERNAL FIT; CAD/CAM; STRENGTH; PROSTHESIS; ADAPTATION;
D O I
10.3390/app122412714
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A well-made provisional fixed prosthesis must present as a preview of the future prosthesis and may also augment the health of the abutments and periodontium. Provisional restorations have been prepared chairside with polymethyl methacrylate (PMMA) since time immemorial. CAD/CAM additive and subtractive technologies have revolutionized the fabrication of interim restorations in dental clinics. The current literature lacks substantial data about retention of provisional crowns manufactured using Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) additive and subtractive techniques with various temporary cements. This in vitro study aims to assess and compare the retention of temporary/provisional anterior crowns based on the combined effect of different digital manufacturing techniques, preparation tapers, and the temporary cements used for cementation. Two maxillary right central incisor typodont teeth were prepared to receive all-ceramic crowns, one with a 10-degree taper and the other with a 20-degree taper. Forty 3D-printed working models with the 10 degrees taper and forty working models with the 20 degrees taper were prepared to receive the temporary crowns. Forty temporary crowns were 3D-printed and forty crowns were milled (20 from each taper group). Kerr Temp-Bond NE conventional cement and Kerr Temp-Bond clear cement were used for cementation in the two groups. The number of samples per test group was 10. All samples were thermocycled and subjected to a universal testing machine to measure the pull-off force until retention loss (N) under tension with a crosshead speed of 5 mm/min. The pull-off force was highest for group 8, i.e., 3D-printed crowns with a 20 degrees taper and cemented with Kerr Temp-Bond clear cement, followed by groups 6, 7, 4, 5, 3, and 2. Group 1, i.e., milled crowns with 10 degrees taper cemented with Kerr Temp-Bond NE conventional cement, exhibited the lowest pull-off retentive force. The clinical selection of long-term provisional crowns fabricated using 3D-printing technology, prepared with 10 degrees or 20 degrees tapers, and cemented with clear cement, is the most favorable in terms of the retention of provisional crowns. 3D-printed provisional crowns can be used as an alternative to conventional and CAD/CAM-milled crowns for long-term provisionalization.
引用
收藏
页数:14
相关论文
共 8 条
  • [1] Evaluation of the Effects of Digital Manufacturing, Preparation Taper, Cement Type, and Aging on the Color Stability of Anterior Provisional Crowns Using Colorimetry
    Sayed, Mohammed E.
    Lunkad, Honey
    Mattoo, Khurshid
    Jokhadar, Hossam F.
    Alresayes, Saad Saleh
    Alqahtani, Nasser M.
    Alshehri, Abdullah Hasan
    Alamri, Mohammad
    Altowairqi, Sultan
    Muaddi, Muhannad
    Huthan, Halah Mohammed
    Baeshen, Safeyah Abdulrahman
    Motlaq, Khalid
    Masmali, Amal M.
    MEDICAL SCIENCE MONITOR BASIC RESEARCH, 2023, 29 : e941919
  • [2] Cumulative effect of digital manufacturing techniques, preparation taper and finish line designs on the retention of aged temporary molar crowns - An in vitro study
    Alqarawi, Firas K.
    Sayed, Mohammed E.
    Dewan, Harisha
    Shaabi, Fawzia Ibraheem
    Naim, Hina
    Ahmad, Manawar
    Hakami, Hanan Ibrahim
    Alsubaiy, Ebrahim Fihaid
    Sultan, Areen
    AlResayes, Saad Saleh
    SAUDI DENTAL JOURNAL, 2024, 36 (11) : 1477 - 1482
  • [3] The Effect of a Digital Manufacturing Technique, Preparation Taper, and Finish Line Design on the Marginal Fit of Temporary Molar Crowns: An In-Vitro Study
    Mugri, Maryam H.
    Dewan, Harisha
    Sayed, Mohammed E.
    Shaabi, Fawzia Ibraheem
    Hakami, Hanan Ibrahim
    Jokhadar, Hossam F.
    Alqahtani, Nasser M.
    Alshahrani, Ahid Amer
    Alabdullah, Abdullah S.
    Alshehri, Abdullah Hasan
    Wadei, Mohammed Hussain Dafer Al
    Arif, Fatimah Yahya
    Adawi, Ebtihag H.
    Al-Makramani, Bandar M. A.
    Chohan, Hitesh
    BIOMEDICINES, 2023, 11 (02)
  • [4] Evaluation of the Milled and ThreeDimensional Digital Manufacturing, 10-Degree and 20-Degree Preparation Taper, Groove and Box Auxiliary Retentive Features, and Conventional and Resin-Based Provisional Cement Type on the Adhesive Failure Stress of 3 mm Short Provisional Crowns
    Sayed, Mohammed E.
    Reddy, Nandalur Kulashekar
    Reddy, Naveen R.
    Mattoo, Khurshid A.
    Jad, Yaser Ali
    Hakami, Abdullah Jaber
    Hakami, Abdulwahab Khalid
    Dighriri, Abdulwahab M.
    Hurubi, Salman Y.
    Hamdi, Bassam Ali
    Alshahrani, Ahid Amer
    Alsubaiy, Ebrahim Fihaid
    Alshehri, Abdullah Hasan
    Alnijaiban, Mashael Abdullah
    MEDICAL SCIENCE MONITOR, 2024, 30 : e943237
  • [5] Effect of Cement Type on Marginal Microleakage of Zirconia Crowns with or without Cervical Margin Relocation: An In Vitro Study
    Farah, Ri
    OPERATIVE DENTISTRY, 2025, 50 (02) : 194 - 203
  • [6] A comparative evaluation of vertical marginal fit of provisional crowns fabricated by computer-aided design/computer-aided manufacturing technique and direct (intraoral technique) and flexural strength of the materials: An in vitro study
    Dureja, Ishita
    Yadav, Bhupender
    Malhotra, Puja
    Dabas, Nupur
    Bhargava, Akshay
    Pahwa, Ripul
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (04): : 314 - 320
  • [7] Effect of cementation technique and cement type on the amount of excess cement in implant-supported cement-retained crown restorations: An in vitro study
    Duzgun, Aybike
    Gunes, Fatma
    Kocacikli, Mustafa
    Yalug, Omer Suat
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03): : 845e1 - 845e7
  • [8] Evaluation of the effect of dentin surface treatment by air abrasion and Er:YAG laser on the retention of metal crowns luted with glass ionomer cement in teeth with reduced crown height: An in vitro study
    Chauhan, Sameer
    Mahajan, Neerja
    Sethuraman, Rajesh
    Naveen, Y. G.
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (02): : 141 - 148