Evaluation of the systematic shifts and absolute frequency measurement of a single Ca+ ion frequency standard

被引:6
|
作者
Huang, Yao [1 ,2 ]
Liu, Peiliang [1 ,2 ,3 ]
Bian, Wu [1 ,2 ,3 ]
Guan, Hua [1 ,2 ]
Gao, Kelin [1 ,2 ]
机构
[1] Chinese Acad Sci, Wuhan Inst Phys & Math, State Key Lab Magnet Resonance & Atom & Mol Phys, Wuhan 430071, Peoples R China
[2] Chinese Acad Sci, Ctr Cold Atom Phys, Wuhan 430071, Peoples R China
[3] Chinese Acad Sci, Grad Sch, Beijing 100080, Peoples R China
来源
APPLIED PHYSICS B-LASERS AND OPTICS | 2014年 / 114卷 / 1-2期
基金
中国国家自然科学基金;
关键词
SR LATTICE CLOCK; FRACTIONAL UNCERTAINTY; OPTICAL CLOCKS; TRANSITION; METROLOGY; SR-88(+); GPS;
D O I
10.1007/s00340-013-5694-9
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper provides a detailed description of the 40 Ca+ optical frequency standard uncertainty evaluation and the absolute frequency measurement of the clock transition, as a summary and supplement for the published papers of Yao Huang et al. (Phys Rev A 84: 053841, 1) and Huang et al. (Phys Rev A 85: 030503, 2). The calculation of systematic frequency shifts, expected for a single trapped Ca+ ion optical frequency standard with a "clock" transition at 729 nm is described. There are several possible causes of systematic frequency shifts that need to be considered. In general, the frequency was measured with an uncertainty of 10(-15) level, and the overall systematic shift uncertainty was reduced to below a part in 10(-15). Several frequency shifts were calculated for the Ca+ ion optical frequency standard, including the trap design, optical and electromagnetic fields geometry and laboratory conditions, including the temperature condition and the altitude of the Ca+ ion. And we measured the absolute frequency of the 729-nm clock transition at the 10(-15) level. An fs comb is referenced to a hydrogen maser, which is calibrated to the SI-second through the Global Positioning System (GPS). Using the GPS satellites as a link, we can calculate the frequency difference of the two hydrogen masers with a long distance, one in WIPM (Wuhan) and the other in National Institute of Metrology (NIM, Beijing). The frequency difference of the hydrogen maser in NIM (Beijing) and the SI-second calculated by BIPM is published on the BIPM web site every 1 month, with a time interval of every 5 days. By analyzing the experimental data obtained within 32 days of a total averaging time of >2 x 10(6) s, the absolute frequency of the Ca-40(+) 4 s S-2(1/2)-3d D-2(5/2) clock transition is measured as 411 042 129 776 393.0 (1.6) Hz with a fractional uncertainty of 3.9 x 10(-15).
引用
收藏
页码:189 / 201
页数:13
相关论文
共 50 条
  • [1] Evaluation of the systematic shifts and absolute frequency measurement of a single Ca+ ion frequency standard
    Yao Huang
    Peiliang Liu
    Wu Bian
    Hua Guan
    Kelin Gao
    Applied Physics B, 2014, 114 : 189 - 201
  • [2] Evaluation of the systematic shifts of a single-40Ca+-ion frequency standard
    Huang, Yao
    Liu, Qu
    Cao, Jian
    Ou, Baoquan
    Liu, Peiliang
    Guan, Hua
    Huang, Xueren
    Gao, Kelin
    PHYSICAL REVIEW A, 2011, 84 (05):
  • [3] Evaluation of the ultimate performances of a Ca+ single-ion frequency standard
    Champenois, C
    Houssin, M
    Lisowski, C
    Knoop, M
    Hagel, G
    Vedel, M
    Vedel, F
    PHYSICS LETTERS A, 2004, 331 (05) : 298 - 311
  • [4] Evaluation of the systematic shifts of a single-40Ca+-ion frequency standard (vol 84, 053841, 2011)
    Huang, Yao
    Liu, Qu
    Cao, Jian
    Ou, Baoquan
    Liu, Peiliang
    Guan, Hua
    Huang, Xueren
    Gao, Kelin
    PHYSICAL REVIEW A, 2012, 85 (01):
  • [5] Effect of laser cooling on frequency standard of single Ca+ ion trapped in a radio-frequency Paul trap
    Wu, LJ
    Shi, TY
    Gao, KL
    CHINESE PHYSICS LETTERS, 2006, 23 (01) : 83 - 86
  • [6] Direct comparison of a Ca+ single-ion clock against a Sr lattice clock to verify the absolute frequency measurement
    Matsubara, Kensuke
    Hachisu, Hidekazu
    Li, Ying
    Nagano, Shigeo
    Locke, Clayton
    Nogami, Asahiko
    Kajita, Masatoshi
    Hayasaka, Kazuhiro
    Ido, Tetsuya
    Hosokawa, Mizuhiko
    OPTICS EXPRESS, 2012, 20 (20): : 22034 - 22041
  • [7] PROSPECT FOR A CA+ OPTICAL FREQUENCY WAVELENGTH STANDARD
    PLUMELLE, F
    DESAINTFUSCIEN, M
    HOUSSIN, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1993, 42 (02) : 462 - 466
  • [8] An optical frequency chain for absolute frequency measurement of the 445 THz strontium trapped ion frequency standard
    Gill, P
    Huang, G
    Lea, SN
    Margolis, HS
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 206 - 207
  • [9] Single-ion optical frequency standards and measurement of their absolute optical frequency
    Madej, AA
    Bernard, JE
    FREQUENCY MEASUREMENT AND CONTROL ADVANCED TECHNIQUES AND FUTURE TRENDS, 2000, 79 : 153 - 194
  • [10] Evaluation of systematic shifts of the 88Sr+ single- ion optical frequency standard at the 10-17 level
    Dube, Pierre
    Madej, Alan A.
    Zhou, Zichao
    Bernard, John E.
    PHYSICAL REVIEW A, 2013, 87 (02):