Finite Element Analysis of the Contact Interface Between Trans-femoral Stump and Prosthetic Socket

被引:0
|
作者
Zhang, Linlin [1 ]
Zhu, Ming [1 ]
Shen, Ling [1 ]
Zheng, Feng [1 ]
机构
[1] Shanghai Med Instrumentat Coll, Dept Precis Med Instrumentat, Shanghai, Peoples R China
关键词
KNEE RESIDUAL LIMB; TIBIAL PROSTHESIS; PRESSURE; STRESS; AMPUTEE; LOAD; FIT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.
引用
收藏
页码:1270 / 1273
页数:4
相关论文
共 50 条
  • [1] Finite element modeling of the contact interface between trans-tibial residual limb and prosthetic socket
    Lee, WCC
    Zhang, M
    Jia, XH
    Cheung, JTM
    MEDICAL ENGINEERING & PHYSICS, 2004, 26 (08) : 655 - 662
  • [2] Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees - A preliminary study
    Lee, VSP
    Solomonidis, SE
    Spence, WD
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (02) : 167 - 180
  • [3] Evaluating the Effect of Changes in Bone Geometry on the Trans-femoral Socket-Residual Limb Interface Using Finite Element Analysis
    van Heesewijk, Alex
    Crocombe, Andy
    Cirovic, Serge
    Taylor, Mathew
    Xu, Wei
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 587 - 591
  • [4] Two dimensional finite element model of a transverse section of the trans-femoral amputee's stump
    Lee, VSP
    Gross, P
    Spence, WD
    Solomonidis, SE
    Paul, JP
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 577 - 584
  • [5] FATIGUE ANALYSIS OF POLYCENTRIC PROSTHETIC KNEE FOR TRANS-FEMORAL AMPUTATION
    Mohanty, Rajesh Kumar
    Mohanty, Ramesh Chandra
    Sabut, Sukanta Kumar
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2023, 23 (01)
  • [6] Finite element analysis of a six-component force sensor for the trans-femoral prosthesis
    Hu, Xiao
    Wang, Rencheng
    Wu, Fangfang
    Jin, Dewen
    Jia, Xiaohong
    Zhang, Jichuan
    Cai, Fuwen
    Zheng, Shuangxi
    DIGITAL HUMAN MODELING, 2007, 4561 : 633 - 639
  • [7] COMPUTER-AIDED SOCKET DESIGN FOR TRANS-FEMORAL AMPUTEES
    TRAVIS, RP
    DEWAR, ME
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1993, 17 (03) : 172 - 179
  • [8] Gait Motion Analysis in the Unrestrained Condition of Trans-Femoral Amputee with a Prosthetic Limb
    Hayashi, Yuichiro
    Tsujiuchi, Nobutaka
    Koizumi, Takayuki
    Uno, Ryuji
    Matsuda, Yasushi
    Tsuchiya, Youtaro
    Inoue, Yoshio
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 3040 - 3043
  • [9] Finite Element Analysis of Donning Procedure of a Prosthetic Transfemoral Socket
    Lacroix, Damien
    Ramirez Patino, Juan Fernando
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (12) : 2972 - 2983
  • [10] Finite Element Analysis of Donning Procedure of a Prosthetic Transfemoral Socket
    Damien Lacroix
    Juan Fernando Ramírez Patiño
    Annals of Biomedical Engineering, 2011, 39 : 2972 - 2983