NOVEL SPIRAL PHANTOM FOR VOLUMETRIC MODULATED ARC THERAPY DELIVERY VERIFICATION

被引:0
|
作者
Tanooka, M. [1 ]
Inoue, H. [1 ]
Doi, H. [2 ]
Takada, Y. [2 ]
Fujiwara, M. [2 ]
Okuhata, K. [1 ]
Ishimaru, F. [1 ]
Yamashita, T. [1 ]
Sakai, T. [1 ]
Nakagawa, H. [1 ]
Oda, M. [1 ]
Yasumasa, K. [1 ]
Sakamoto, K. [1 ]
Kamikonya, N. [2 ]
Hirota, S. [3 ]
机构
[1] Hosp Hyogo Coll Med, Clin Radiol, Nishinomiya, Hyogo, Japan
[2] Hyogo Coll Med, Radiat Oncol, Nishinomiya, Hyogo, Japan
[3] Hyogo Coll Med, Radiol, Nishinomiya, Hyogo, Japan
关键词
D O I
10.1016/S0167-8140(11)71218-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
1096
引用
收藏
页码:S408 / S408
页数:1
相关论文
共 50 条
  • [1] Novel Spiral Phantom for Volumetric Modulated Arc Therapy Delivery Verification
    Tanooka, M.
    Sakai, T.
    Inoue, H.
    Doi, H.
    Takada, Y.
    Fujiwara, M.
    Yasumasa, K.
    Sakamoto, K.
    Kamikonya, N.
    Hirota, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S769 - S769
  • [2] Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy
    Letourneau, Daniel
    Publicover, Julia
    Kozelka, Jakub
    Moseley, Douglas J.
    Jaffray, David A.
    [J]. MEDICAL PHYSICS, 2009, 36 (05) : 1813 - 1821
  • [3] Validation and Testing of Performance of a Novel Phantom Specially Designed for Volumetric Modulated Arc Therapy MU/dose Verification
    Sarkar, B.
    Jassal, K.
    Sureka, C.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Verification of dose distribution for volumetric modulated arc therapy total marrow irradiation in a humanlike phantom
    Surucu, Murat
    Yeginer, Mete
    Kavak, Gulbin O.
    Fan, John
    Radosevich, James A.
    Aydogan, Bulent
    [J]. MEDICAL PHYSICS, 2012, 39 (01) : 281 - 288
  • [5] DOSIMETRIC VERIFICATION OF RAPIDARC™ VOLUMETRIC MODULATED ARC THERAPY
    Medin, J.
    Kjaer-Kristoffersen, F.
    Ceberg, S.
    Back, S.
    Gustavsson, H.
    Archambault, Y.
    Bocanek, J.
    Cozzi, L.
    Eberhard, V.
    Gomola, I.
    Wiberg, I.
    Korreman, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S47 - S48
  • [6] Characterization of a Delivery System for Volumetric Modulated Arc Therapy
    Matuszak, M.
    Sui, H.
    Yan, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [7] Initial Experience with the Delivery of Volumetric Modulated Arc Therapy
    Shepard, D. M.
    Cao, D.
    Afghan, M. K. N.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [8] Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom
    Tanooka, Masao
    Doi, Hiroshi
    Miura, Hideharu
    Inoue, Hiroyuki
    Niwa, Yasue
    Takada, Yasuhiro
    Fujiwara, Masayuki
    Sakai, Toshiyuki
    Sakamoto, Kiyoshi
    Kamikonya, Norihiko
    Hirota, Shozo
    [J]. JOURNAL OF RADIATION RESEARCH, 2013, 54 (06) : 1153 - 1159
  • [9] Dosimetric Verification for Volumetric Modulated Arc Therapy (VMAT) with Gating
    Qian, J.
    Xing, L.
    Luxton, G.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Verification of Geometric Parameters in Volumetric Modulated Arc Therapy (VMAT)
    Qian, J.
    Lee, L.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)