Impact of low mesopic contrast sensitivity outcomes in different types of modern multifocal intraocular lenses

被引:40
|
作者
Plaza-Puche, Ana B. [1 ]
Alio, Jorge L. [1 ,2 ]
Sala, Esperanza [1 ]
Mojzis, Peter [3 ]
机构
[1] Vissum Alicante, Alicante, Spain
[2] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[3] Reg Hosp, Eye Dept, Havlickuv Brod, Czech Republic
关键词
Cataract surgery; Contrast sensitivity; Multifocal intraocular lenses; VISUAL-ACUITY; BILATERAL IMPLANTATION; OPTICAL-PERFORMANCE; CATARACT-SURGERY; DIFFRACTIVE IOL; MONOFOCAL IOLS; EYES; TESTS;
D O I
10.5301/ejo.5000777
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the low mesopic contrast sensitivity function (LMCSF) of patients implanted with different modern optical bifocal and trifocal designs of multifocal intraocular lenses (mfIOLs). Methods: This prospective, comparative, nonrandomized consecutive case series included 180 eyes that underwent cataract surgery. Six groups of eyes were differentiated: group A, eyes with the diffractive AT LISA tri 839MP; group B, eyes with diffractive FineVision; group C, eyes with the bifocal Lentis Mplus-LS313; group D, eyes with the diffractive bifocal Acri. Lisa 366D; group E, eyes with the diffractive apodized Acrysof ReSTOR SN6AD1; group F, as the control group, implanted with a monofocal spherical intraocular lens. The LMCSF was evaluated with the OPTEC (R) 6500 device at 3 months postoperatively using a luminance of 3 cd/m(2). Results: No significant differences among groups were detected in LMCSF for the spatial frequencies of 1.5, 3.0, 6.0, and 12.0 cpd (1.5 cpd: F = 1.81, p = 0.13; 3.0 cpd: F = 1.14, p = 0.14; 6.0 cpd: F = 1.87, p = 0.11; 12.0 cpd: F = 1.26, p = 0.29), but significant differences were found among groups for the spatial frequency of 18 cpd (F = 2.62, p = 0.03). When comparing the groups in pairs, only statistically significant differences were observed between groups E and F for the spatial frequency of 18.0 cpd (t = 3.27, p = 0.03) with better values for group F. Conclusion: No significant differences were observed in LMCSF among the different mfIOLs studied. The third focus of trifocal IOL models did not adversely affect the LMCSF. The ReSTOR SN6AD1 showed the poorest LMCSF for the highest spatial frequency analyzed when compared with the control group.
引用
收藏
页码:612 / 617
页数:6
相关论文
共 50 条
  • [1] CONTRAST SENSITIVITY IN MULTIFOCAL INTRAOCULAR LENSES
    RAVALICO, G
    BACCARA, F
    RINALDI, G
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01): : 22 - 25
  • [2] Visual performance with multifocal intraocular lenses -: Mesopic contrast sensitivity under distance and near conditions
    Montés-Micó, R
    España, E
    Bueno, I
    Charman, WN
    Menezo, JL
    [J]. OPHTHALMOLOGY, 2004, 111 (01) : 85 - 96
  • [3] CONTRAST SENSITIVITY THROUGH MULTIFOCAL AND MONOFOCAL INTRAOCULAR LENSES
    AKUTSU, H
    LEGGE, GE
    SHOWALTER, M
    KIRBY, VM
    LINDSTROM, RL
    ZABEL, RW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 799 - 799
  • [4] CONTRAST SENSITIVITY AND READING THROUGH MULTIFOCAL INTRAOCULAR LENSES
    AKUTSU, H
    LEGGE, GE
    SHOWALTER, M
    LINDSTROM, RL
    ZABEL, RW
    KIRBY, VM
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1992, 110 (08) : 1076 - 1080
  • [5] Impact of Multifocal Intraocular Lenses on Contrast Sensitivity Function in Vision Degrading Vitreopathy
    Yee, Kenneth M. P.
    Nguyen, Justin
    Nguyen-Cuu, Jeannie
    Sebag, J.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [6] A COMPARISON OF CONTRAST SENSITIVITY TEST METHODS FOR MULTIFOCAL INTRAOCULAR LENSES
    ODONOGHUE, E
    KELLY, S
    NACER, M
    STOREY, J
    MURRAY, I
    MCLEOD, D
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1281 - 1281
  • [7] Tritan colour contrast sensitivity function in refractive multifocal intraocular lenses
    Pieh, S
    Hanselmayer, G
    Lackner, B
    Marvan, P
    Grechenig, A
    Weghaupt, H
    Vass, C
    Skorpik, C
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (07) : 811 - 815
  • [8] Contrast sensitivity and glare disability with diffractive and refractive multifocal intraocular lenses
    Pieh, S
    Weghaupt, H
    Skorpik, C
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05): : 659 - 662
  • [9] Analysis of defocus curves of different modern multifocal intraocular lenses
    Plaza-Puche, Ana B.
    Alio, Jorge L.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (05) : 412 - 417
  • [10] Contrast acuity and contrast sensitivity after binocular implantation of multifocal or monofocal intraocular lenses
    Breitkopf, J
    Eisenmann, D
    Jacobi, FK
    [J]. OPHTHALMOLOGE, 1997, 94 (07): : 519 - 522