Evaluation of Electromagnetic Fields in a Hospital for Safe Use of Electronic Medical Equipment

被引:8
|
作者
Ishida, Kai [1 ]
Fujioka, Tomomi [2 ]
Endo, Tetsuo [2 ]
Hosokawa, Ren [3 ]
Fujisaki, Tetsushi [4 ]
Yoshino, Ryoji [4 ]
Hirose, Minoru [3 ]
机构
[1] Tokyo Healthcare Univ, Fac Healthcare, Div Healthcare Informat, Setagaya 3-11-3, Tokyo 1548568, Japan
[2] Taisei Corp, Adv Technol Dev Sect, Bldg Technol Dev Dept, Ctr Technol, Nase Cho 344-1, Yokohama, Kanagawa 2450051, Japan
[3] Kitasato Univ, Sch Allied Hlth Sci, Dept Med Safety Engn, Kitasato 1-15-1, Sagamihara, Kanagawa 2520373, Japan
[4] Environm Survey Off, Shinbashi 3-7-7, Tokyo 1050004, Japan
关键词
Electromagnetic environment; Immunity; Radio wave; Cellphone; Measurement; INTERFERENCE; IMPLEMENTATION; MANAGEMENT;
D O I
10.1007/s10916-015-0411-3
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Establishment of electromagnetic compatibility is important in use of electronic medical equipment in hospitals. To evaluate the electromagnetic environment, the electric field intensity induced by electromagnetic radiation in broadcasting spectra coming from outside the hospital was measured in a new hospital building before any patients visited the hospital and 6 months after the opening of the hospital. Various incoming radio waves were detected on the upper floors, with no significant difference in measured levels before and after opening of the hospital. There were no cellphone terminal signals before the hospital opened, but these signals were strongly detected at 6 months thereafter. Cellphone base stations signals were strongly detected on the upper floors, but there were no signals at most locations in the basement and in the center of the building on the lower floors. A maximum electrical intensity of 0.28 V/m from cellphone base stations (2.1 GHz) was detected at the south end of the 2nd floor before the hospital opened. This value is lower than the EMC marginal value for general electronic medical equipment specified in IEC 60601-1-2 (3 V/m). Therefore, electromagnetic interference with electronic medical equipment is unlikely in this situation. However, cellphone terminal signals were frequently detected in non-base station signal areas. This is a concern, and understanding signal strength from cellphone base stations at a hospital is important for promotion of greater safety.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [1] Evaluation of Electromagnetic Fields in a Hospital for Safe Use of Electronic Medical Equipment
    Kai Ishida
    Tomomi Fujioka
    Tetsuo Endo
    Ren Hosokawa
    Tetsushi Fujisaki
    Ryoji Yoshino
    Minoru Hirose
    Journal of Medical Systems, 2016, 40
  • [2] Measurement for electromagnetic susceptibility of the electronic medical equipment
    Kwangwoon Univ, Seoul, Korea, Republic of
    Asia Pacif Microwave Conf Proc APMC, (206-209):
  • [3] SAFE USE OF ELECTRO-MEDICAL EQUIPMENT
    MONKS, PS
    ANAESTHESIA, 1971, 26 (03) : 264 - +
  • [4] USE OF ELECTRONIC EQUIPMENT IN A MEDICAL CENTER
    GONDA, I
    RICHTER, E
    MEDICAL RESEARCH ENGINEERING, 1971, 10 (01) : 21 - &
  • [5] Possible electromagnetic interference with electronic medical equipment by radio waves coming from outside the hospital
    Hanada E.
    Kodama K.
    Takano K.
    Watanabe Y.
    Nose Y.
    Journal of Medical Systems, 2001, 25 (4) : 257 - 267
  • [6] MEDICAL ELECTRONIC EQUIPMENT - CAN IT SURVIVE IN THE NUCLEAR ELECTROMAGNETIC ENVIRONMENT
    OLIVA, SA
    STROMBERG, LR
    MILITARY MEDICINE, 1979, 144 (01) : 28 - 30
  • [7] A practical procedure to prevent electromagnetic interference with electronic medical equipment
    Hanada E.
    Takano K.
    Antoku Y.
    Matsumura K.
    Watanabe Y.
    Nose Y.
    Journal of Medical Systems, 2002, 26 (1) : 61 - 65
  • [8] Electromagnetic interference with electronic medical equipment induced by automatic conveyance systems
    Hanada E.
    Watanabe Y.
    Nose Y.
    Journal of Medical Systems, 2000, 24 (1) : 11 - 20
  • [9] Electromagnetic Noise Superimposed on the Electric Power Supply to Electronic Medical Equipment
    Eisuke Hanada
    Kyoko Takano
    Kenji Kodama
    Journal of Medical Systems, 2003, 27 (4) : 381 - 392
  • [10] Study on the Electromagnetic Environmental Effects for the Detection and Evaluation of Electronic Equipment
    Yu Daojie
    Lin Xin
    Cui Weiqun
    Guo Yuhua
    TECHNOLOGY AND APPLICATION OF ELECTRONIC INFORMATION, 2009, : 357 - 361