Quantitative assessment by measurement and modeling of mobile target elongation in cone-beam computed tomographic imaging

被引:2
|
作者
Ali, Imad [1 ]
Alsbou, Nesreen [2 ]
Algan, Ozer [1 ]
Herman, Terence [1 ]
Ahmad, Salahuddin [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dept Radiat Oncol, Oklahoma City, OK 73104 USA
[2] Ohio No Univ, Dept Elect & Comp Engn, Ada, OH 45810 USA
来源
关键词
cone-beam CT; respiratory motion; image artifacts; motion model; mobile target; elongation; HELICAL CT; RECONSTRUCTION; ARTIFACTS; FEASIBILITY; QUALITY; IMAGES; IMPACT;
D O I
10.1120/jacmp.v15i3.4634
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to assess quantitatively elongation of mobile targets in cone-beam CT (CBCT) imaging by measurement and modeling. A mathematical model was derived that predicts the measured lengths of mobile targets and its dependence on target size and motion patterns in CBCT imaging. Three tissue-equivalent targets of differing sizes were inserted in an artificial thorax phantom to simulate lung lesions. Respiratory motion was mimicked with a mobile phantom that moves in one-dimension along the superior-inferior direction at a respiration frequency of 0.24 Hz for eight different amplitudes in the range 0-40 mm. A mathematical model was derived to quantify the variations in target lengths and its dependence on phantom motion parameters in CBCT. Predictions of the model were verified by measurement of the lengths of mobile targets in CBCT images. The model predicts that target lengths increased linearly with increase in speed and amplitude of phantom motion in CBCT. The measured lengths of mobile targets imaged with CBCT agreed with the calculated lengths within half-slice thickness spatial resolution. The maximal length of a mobile target was independent of the frequency and phase of motion. Elongation of mobile targets was similar in half-fan and full-fan CBCT for similar motion patterns, as long as the targets remained within the imaging view. Mobile targets elongated linearly with phantom speed and motion amplitude in CBCT imaging. The model introduced in this work assessed quantitatively the variation in target lengths induced by motion, which may be a useful tool to consider elongations of mobile targets in CBCT applications in diagnostic imaging and radiotherapy.
引用
收藏
页码:266 / 274
页数:9
相关论文
共 50 条
  • [1] Quantitative Assessment by Measurement and Modeling of Mobile Target Elongation in Cone-Beam Computer Tomographic Imaging
    Ali, I.
    Alsbou, N.
    Algan, O.
    Herman, T.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Modeling and measurement of the variations of CT number distributions for mobile targets in cone-beam computed tomographic imaging
    Ali, Imad
    Alsbou, Nesreen
    Ahmad, Salahuddin
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (01): : 360 - 372
  • [3] Theoretical Modeling of the Variations of CT Number Distributions for Mobile Targets in Cone-Beam Computed Tomographic Imaging
    Ali, I.
    Alsbou, N.
    Algan, O.
    Herman, T.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [4] Assessment of Cone-beam Computed Tomographic Referral Reasons and the Impact of Cone-beam Computed Tomographic Evaluation on Decision Treatment Planning Procedure in Endodontics
    Kakavetsos, Vasileios D.
    Markou, Maria-Eleni
    Tzanetakis, Giorgos N.
    [J]. JOURNAL OF ENDODONTICS, 2020, 46 (10) : 1414 - 1419
  • [5] A Motion Algorithm to Extract Physical and Motion Parameters of a Mobile Target in Cone-Beam Computed Tomographic Imaging Retrospective to Image Reconstruction
    Ali, I.
    Alsbou, N.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 215 - 216
  • [6] Quantitative Measurement and Modeling of Target Volume Changes by Respiratory Motion in CT and Cone-Beam CT
    Jackson, S.
    Ahmad, S.
    Ali, I.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3683 - 3683
  • [7] Measurement of skin dose from cone-beam computed tomography imaging
    Akyalcin, Sercan
    English, Jeryl D.
    Abramovitch, Kenneth M.
    Rong, Xiujiang J.
    [J]. HEAD & FACE MEDICINE, 2013, 9
  • [8] Measurement of skin dose from cone-beam computed tomography imaging
    Sercan Akyalcin
    Jeryl D English
    Kenneth M Abramovitch
    Xiujiang J Rong
    [J]. Head & Face Medicine, 9
  • [9] Cone Beam Computed Tomographic imaging in orthodontics
    Scarfe, W. C.
    Azevedo, B.
    Toghyani, S.
    Farman, A. G.
    [J]. AUSTRALIAN DENTAL JOURNAL, 2017, 62 : 33 - 50
  • [10] Cone-beam computed tomographic imaging of central giant cell granuloma: A comprehensive review
    Tahmasbi-Arashlow, Mehrnaz
    Patel, Paras B.
    Nair, Madhu K.
    Liang, Hui
    Cheng, Yi-Shing Lisa
    [J]. IMAGING SCIENCE IN DENTISTRY, 2022, 52 (02) : 123 - 131