MEG and EEG demonstrate similar test-retest reliability of the 40 Hz auditory steady-state response

被引:30
|
作者
Legget, Kristina T. [1 ,2 ]
Hild, Allison K. [1 ,2 ]
Steinmetz, Sarah E. [1 ,2 ]
Simon, Steven T. [2 ]
Rojas, Donald C. [3 ]
机构
[1] Univ Colorado, Sch Med, Dept Psychiat, Anschutz Med Campus 13001 E 17th Pl, Aurora, CO 80045 USA
[2] Univ Colorado, Sch Med, Dept Med, Anschutz Med Campus, Aurora, CO USA
[3] Colorado State Univ, Dept Psychol, Ft Collins, CO 80523 USA
基金
美国国家卫生研究院;
关键词
Magnetoencephalography; Electroencephalography; Auditory evoked response; Inter-trial phase coherence; Auditory steady state response; SCHIZOTYPAL PERSONALITY-DISORDER; FALSE DISCOVERY RATE; BIPOLAR DISORDER; 1ST-DEGREE RELATIVES; RAT MODEL; SCHIZOPHRENIA; PHASE; SYNCHRONIZATION; STIMULATION; COHERENCE;
D O I
10.1016/j.ijpsycho.2017.01.013
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
The auditory steady-state response (ASSR) is increasingly being used as a biomarker in neuropsychiatric disorders, but research investigating the test-retest reliability of this measure is needed. We previously reported ASSR reliability, measured by electroencephalography (EEG), to 40 Hz amplitude-modulated white noise and click train stimuli. The purpose of the current study was to (a) assess the reliability of the MEG-measured ASSR to 40 Hz amplitude-modulated white noise and click train stimuli, and (b) compare test-retest reliability between MEG and EEG measures of ASSR, which has not previously been investigated. Additionally, impact of stimulus parameter choice on reliability was assessed, by comparing responses to white noise and click train stimuli. Test-retest reliability, across sessions approximately one week apart, was assessed in 17 healthy adults. On each study day, participants completed two passive listening tasks (white noise and click train stimuli) during separate MEG and EEG recordings. Between-session correlations for evoked power and inter-trial phase coherence (ITPC) were assessed following source-space projection. Overall, the MEG-measured ASSR was significantly correlated between sessions (p < 0.05, FDR corrected), suggesting acceptable test-retest reliability. Results suggest greater response reproducibility for ITPC compared to evoked responses and for click train compared to white noise stimuli, although further study is warranted. No significant differences in reliability were observed between MEG and EEG measures, suggesting they are similarly reliable. This work supports use of the ASSR as a biomarker in clinical interventions with repeated measures. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 23
页数:8
相关论文
共 50 条
  • [1] Test-Retest Reliability of the 40 Hz EEG Auditory Steady-State Response
    McFadden, Kristina L.
    Steinmetz, Sarah E.
    Carroll, Adam M.
    Simon, Steven T.
    Wallace, Alissa
    Rojas, Donald C.
    [J]. PLOS ONE, 2014, 9 (01):
  • [2] Auditory steady-state responses in normal hearing adults: A test-retest reliability study
    D'haenens, Wendy
    Vinck, Bart M.
    De Vel, Eddy
    Maes, Leen
    Bockstael, Annelies
    Keppler, Hannah
    Philips, Birgit
    Swinnen, Freya
    Dhooge, Ingeborg
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2008, 47 (08) : 489 - 498
  • [3] Test-retest reliability of mismatch negativity and gamma-band auditory steady-state response in patients with schizophrenia
    Jiao, Xiong
    Hu, Qiang
    Tang, Yingying
    Qian, Zhenying
    Tong, Shanbao
    Wang, Jijun
    Sun, Junfeng
    [J]. SCHIZOPHRENIA RESEARCH, 2022, 240 : 165 - 174
  • [4] MEG-measured auditory steady-state oscillations show high test-retest reliability: A sensor and source-space analysis
    Tan, H. -R. M.
    Gross, J.
    Uhlhaas, P. J.
    [J]. NEUROIMAGE, 2015, 122 : 417 - 426
  • [5] 40 Hz Auditory Steady-State Response: The Impact of Handedness and Gender
    Melynyte, Sigita
    Pipinis, Evaldas
    Genyte, Vaida
    Voicikas, Aleksandras
    Rihs, Tonia
    Griskova-Bulanova, Inga
    [J]. BRAIN TOPOGRAPHY, 2018, 31 (03) : 419 - 429
  • [6] INTRACORTICAL GENERATORS OF THE 40 HZ AUDITORY STEADY-STATE RESPONSE IN THE CAT
    KARMOS, G
    MAKELA, JP
    ULBERT, I
    [J]. EUROPEAN JOURNAL OF NEUROSCIENCE, 1992, : 145 - 145
  • [7] CLINICAL USE OF THE 40-HZ AUDITORY STEADY-STATE RESPONSE
    PLOURDE, G
    [J]. INTERNATIONAL ANESTHESIOLOGY CLINICS, 1993, 31 (04) : 107 - 120
  • [8] INTRACORTICAL COMPONENTS OF THE 40 HZ AUDITORY STEADY-STATE RESPONSE IN THE CAT
    KARMOS, G
    MAKELA, JP
    ULBERT, I
    [J]. INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1993, 14 (02) : 131 - 131
  • [9] 40 Hz Auditory steady-state response and EEG spectral edge frequency during sufentanil anaesthesia
    I. Gilron
    G. Plourde
    W. Marcantoni
    F. Varin
    [J]. Canadian Journal of Anaesthesia, 1998, 45 : 115 - 121
  • [10] 40 Hz auditory steady-state response and EEG spectral edge frequency during sufentanil anaesthesia
    Gilron, I
    Plourde, G
    Marcantoni, W
    Varin, F
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (02): : 115 - 121