Biomechanical Evaluation of a Novel Autogenous Bone Interbody Fusion Cage for Posterior Lumbar Interbody Fusion in a Cadaveric Model

被引:7
|
作者
Wang, Le [1 ]
Malone, Kyle T. [2 ]
Huang, Hai [1 ]
Zhang, Zhenshan [1 ]
Zhang, Zhi [1 ]
Zhang, Liang [1 ]
Li, Jian [1 ]
机构
[1] Guangzhou Med Univ, Affiliated Hosp 3, Inst Orthopaed & Traumatol, Guangzhou 510150, Guangdong, Peoples R China
[2] NNI Res Fdn, Las Vegas, NV USA
基金
中国国家自然科学基金;
关键词
posterior lumbar interbody fusion; autogenous bone; cage; pedicle screws; DONOR SITE PAIN; OUTCOME ASSESSMENT; GRAFT; IMPLANT; DESIGN; SPINE; INSTRUMENTATION; STABILIZATION; COMPLICATIONS; FIXATION;
D O I
10.1097/BRS.0000000000000291
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A human cadaveric biomechanical study of a novel, prefabricated autogenous bone interbody fusion (ABIF) cage. Objective. To evaluate the biomechanical properties of the ABIF cage in a single-level construct with and without transpedicular screw and rod fixation. Summary of Background Data. In current practice, posterior lumbar interbody fusion is generally carried out using synthetic interbody spacers or corticocancellous iliac crest bone graft (ICBG) in combination with posterior instrumentation. However, questions remain concerning the use of synthetic intervertebral implants as well as the morbidity ICBG harvesting. Therefore, ABIF cage has been developed to obviate some of the challenges in conventional posterior lumbar interbody fusion instrumentation and to facilitate the fusion process. Methods. Eighteen adult cadaveric lumbosacral (L3-S1) specimens were tested. Test conditions included single lumbosacral segments across (1) intact, (2) decompressed, (3) intervertebral cage alone, and (4) intervertebral cage with bilateral transpedicular fixation. Range of motion (ROM), neutral zone (NZ), and axial failure load were tested for each condition. Results. The ICBG, polyetheretherketone cage, or ABIF cage alone exhibited a significantly lower (P < 0.05) ROM and NZ than the decompressed spine. In comparison with the intact spine, all 3 test conditions without supplemental fixation were able to decrease ROM and NZ to near intact levels. When stabilized with pedicle screws, the ROM was significantly less and the NZ was significantly lower (P < 0.05) for each group both compared with the intact spine. In axial compression testing, the failure load of polyetheretherketone cage was the highest, with no significant difference between the ICBG and the ABIF cage. Conclusion. These data suggest that the novel ABIF cage can bear the physiological intervertebral peak load, similar to ICBG. When combined with pedicle screw and rod fixation, it exhibits similar biomechanical properties as the polyetheretherketone cage plus posterior instrumentation. Based on the biomechanical properties of ABIF cage, the prospect of these cages in clinical practice is expected.
引用
收藏
页码:E684 / E692
页数:9
相关论文
共 50 条
  • [1] Comparison of two interbody fusion cages for posterior lumbar interbody fusion in a cadaveric model
    Wang, Shih-Tien
    Goel, Vijay K.
    Fu, Chong-Yau
    Kubo, Shinichiro
    Choi, Woosung
    Liu, Chien-Lin
    Chen, Tain-Hsiung
    INTERNATIONAL ORTHOPAEDICS, 2006, 30 (04) : 299 - 304
  • [2] Comparison of two interbody fusion cages for posterior lumbar interbody fusion in a cadaveric model
    Shih-Tien Wang
    Vijay K. Goel
    Chong-Yau Fu
    Shinichiro Kubo
    Woosung Choi
    Chien-Lin Liu
    Tain-Hsiung Chen
    International Orthopaedics, 2006, 30 : 299 - 304
  • [3] BIOMECHANICAL EVALUATION OF AN EXPANDABLE CAGE IN SINGLE SEGMENT POSTERIOR LUMBAR INTERBODY FUSION
    Bhatia, Nitin N.
    Lee, Kenneth H.
    Bui, Chris
    Wahba, George M.
    Estess, Allyson A.
    Luna, Mario
    Lee, Thay Q.
    PROCEEDINGS OF THE 4TH FRONTIERS IN BIOMEDICAL DEVICES CONFERENCE AND EXPOSITION - 2009, 2009, : 11 - 12
  • [4] Biomechanical evaluation of autologous bone-cage in posterior lumbar interbody fusion: a finite element analysis
    Haodong Zhu
    Weibin Zhong
    Ping Zhang
    Xiaoming Liu
    Junming Huang
    Fatai Liu
    Jian Li
    BMC Musculoskeletal Disorders, 21
  • [5] A biomechanical and histological evaluation of a bioresorbable lumbar interbody fusion cage
    Hojo, Y
    Kotani, Y
    Ito, M
    Abumi, K
    Kadosawa, T
    Shikinami, Y
    Minami, A
    BIOMATERIALS, 2005, 26 (15) : 2643 - 2651
  • [6] Biomechanical evaluation of autologous bone-cage in posterior lumbar interbody fusion: a finite element analysis
    Zhu, Haodong
    Zhong, Weibin
    Zhang, Ping
    Liu, Xiaoming
    Huang, Junming
    Liu, Fatai
    Li, Jian
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [7] Biomechanical evaluation of Percutaneous endoscopic posterior lumbar interbody fusion and minimally invasive transforaminal lumbar interbody fusion: a biomechanical analysis
    Li, Jia-Rui
    Yan, Yang
    Wu, Xiao-Gang
    He, Li-Ming
    Feng, Hao-Yu
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (03) : 285 - 295
  • [8] Biomechanical Evaluation of an Expandable Cage in Single-Segment Posterior Lumbar Interbody Fusion
    Bhatia, Nitin N.
    Lee, Kenneth H.
    Bui, Christopher N. H.
    Luna, Mario
    Wahba, George M.
    Lee, Thay Q.
    SPINE, 2012, 37 (02) : E79 - E85
  • [9] Biomechanical evaluation of posterior and anterior lumbar interbody fusion techniques
    Voor, MJ
    Mehta, S
    Wang, M
    Zhang, YM
    Mahan, J
    Johnson, JR
    JOURNAL OF SPINAL DISORDERS, 1998, 11 (04): : 328 - 334
  • [10] The Ray threaded fusion cage for posterior lumbar interbody fusion
    Onesti, ST
    Ashkenazi, E
    NEUROSURGERY, 1998, 42 (01) : 200 - 204