Effects of endovascular radiation from a beta-particle-emitting stent in a porcine coronary restenosis model - A dose-response study

被引:98
|
作者
Carter, AJ
Laird, JR
Bailey, LR
Hoopes, TG
Farb, A
Fischell, DR
Fischell, RE
Fischel, TA
Virmani, R
机构
[1] ARMED FORCES INST PATHOL,WASHINGTON,DC 20306
[2] VANDERBILT UNIV,SCH MED,DIV CARDIOL,NASHVILLE,TN 37212
关键词
stenosis; stents; arteries;
D O I
10.1161/01.CIR.94.10.2364
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Neointimal formation causes restenosis after intracoronary stent placement. Endovascular radiation delivered via a stent has been shown to reduce neointimal formation after placement in porcine and rabbit iliac arteries. The objective of this study was to evaluate the dose-related effects of a beta-particle-emitting radioactive stent in a porcine coronary restenosis model. Methods and Results Thirty-seven swine underwent placement of 35 nonradioactive and 39 beta-particle-emitting stents with activity levels of 23.0, 14.0, 6.0, 3.0, 1.0, 0.5, and 0.15 mu Ci of P-32. Treatment effect was assessed by histological analysis 28 days after stent placement. Neointimal and medial smooth muscle cell density were inversely related to increasing stent activity. The neointima of the high-activity (3.0- to 23.0-mu Ci) scents consisted of fibrin, erythrocytes, occasional inflammatory cells, and smooth muscle cells with partial endothelialization of the luminal surface. In the 1.0-mu Ci stents, the neointima was expanded and consisted of smooth muscle cells and a proteoglycan-rich matrix. The neointima of the low-activity (0.15- and 0.5-mu Ci) stents was composed of smooth muscle cells and matrix with complete endothelialization of the luminal surface. At low and high stent activities, there was a reduction in neointimal area (low, 1.63+/-0.67 mm(2) and high, 1.73+/-0.97 mm(2) versus control, 2.40+/-0.87 mm(2)) and percent area stenosis (low, 26+/-7% and high, 26+/-12%) compared with control stents (37+/-12%, P less than or equal to.01). The 1.0-mu Ci stents, however, had greater neointimal formation (4.67+/-1.50 mm(2)) and more luminal narrowing (64+/-16%) than the control stents (P<.0001). Conclusions The differential response to the doses of continuous beta-particle irradiation used in this experimental model suggests a complex biological interaction of endovascular radiation and vascular repair after stent placement. Further study is required to determine the clinical potential for this therapy to prevent stent restenosis.
引用
收藏
页码:2364 / 2368
页数:5
相关论文
共 50 条
  • [1] Inhibition of neointimal proliferation with low-dose irradiation from a beta-particle-emitting stent
    Laird, JR
    Carter, AJ
    Kufs, WM
    Hoopes, TG
    Farb, A
    Nott, SH
    Fischell, RE
    Fischell, DR
    Virmani, R
    Fischell, TA
    CIRCULATION, 1996, 93 (03) : 529 - 536
  • [2] Endovascular irradiation from β-particle-emitting gold stents results in increased neointima formation in a porcine restenosis model
    Schulz, C
    Niederer, C
    Andres, C
    Herrmann, RA
    Lin, XL
    Henkelmann, R
    Panzer, W
    Herrmann, C
    Regulla, DF
    Wolf, I
    Ulm, K
    Alt, E
    CIRCULATION, 2000, 101 (16)
  • [3] Dose-response effects of 32P radioactive stents in an atherosclerotic porcine coronary model
    Carter, AJ
    Scott, D
    Bailey, L
    Hoopes, T
    Jones, R
    Virmani, R
    CIRCULATION, 1999, 100 (14) : 1548 - 1554
  • [4] Effects of β-radiation using a Holmium-166 coated balloon on neointimal hyperplasia in a porcine coronary stent restenosis model
    Kim, W
    Jeong, MH
    Park, OY
    Rhew, JY
    Bom, HS
    Choi, SJ
    Park, KB
    Kim, EH
    Kim, JH
    Ahn, YK
    Park, JT
    Cho, JG
    Park, JC
    Kang, JC
    CIRCULATION JOURNAL, 2003, 67 (07) : 625 - 629
  • [5] PRECLINICAL EVALUATION OF THE VASCULAR EFFECTS OF REJUVENATE® COBALT CHROMIUM CORONARY STENT SYSTEM IMPLANTED IN THE PORCINE CORONARY IN STENT RESTENOSIS MODEL
    Ali, Murtaza Najabat
    Mir, Mariam
    Buszman, Piotr
    PAKISTAN HEART JOURNAL, 2021, 54 (02): : 132 - 138
  • [6] In vivo adenovirus mediated gene transfer in a porcine coronary stent model: A dose response, toxicity study
    Frimerman, A
    Eigler, N
    Fishbein, MC
    Ren, M
    Makkar, R
    Litvack, F
    AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 : TC266 - TC266
  • [7] Dose Dependent Vascular Response Following Delivery Of Sirolimus Via Fast Releasing, Biodegradable Polymer Stent Matrix: An Experimental Study In The Porcine Coronary Model Of Restenosis
    Buszman, Piotr P.
    Orlik, Bartlomiej
    Pajak, Jacek
    Jelonek, Michal
    Krauze, Agata
    Janas, Adam
    Legutko, Jacek
    Pawel, Buszman E.
    Milewski, Krzysztof P.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (15) : B242 - B243
  • [8] Beta-radiation therapy using a holmium-166-coated balloon inhibits porcine coronary stent restenosis
    Jeong, MH
    Kim, W
    Ahn, YK
    Park, JT
    Cho, JG
    Park, JC
    Park, KB
    Kang, JC
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (6A): : 103H - 103H
  • [9] Experimental results with 90yttrium beta-particle emitting radioactive stents in a porcine model of restenosis
    Carter, AJ
    Sweet, W
    Bailey, L
    Jones, R
    Virmani, R
    Fischell, TA
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 1999, 12 (04) : 291 - 297
  • [10] Dose-response study of the Med-aSpire nitric oxide-eluting stent in a porcine iliac noninjury model
    Hou, D
    Narciso, H
    Kamdar, K
    Zhang, P
    March, K
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 97L - 97L