Evaluation of a disintegrin-like and metalloprotease with thrombospondin type 1 repeat motifs 13 (ADAMTS13) activity enzyme-linked immunosorbent assay for measuring plasma ADAMTS13 activity in dogs

被引:1
|
作者
Maruyama, Haruhiko [1 ]
Kaneko, Michiko [1 ]
Otake, Taiga [1 ]
Kano, Rui [1 ]
Yamaya, Yoshiki [2 ]
Watari, Toshihiro [2 ]
Hasegawa, Atsuhiko [3 ]
Kamata, Hiroshi [1 ]
机构
[1] Nihon Univ, Lab Vet Pathobiol, Dept Vet Med, Fujisawa, Kanagawa 2520880, Japan
[2] Nihon Univ, Lab Comprehens Vet Clin Studies, Dept Vet Med, Fujisawa, Kanagawa 2520880, Japan
[3] Teikyo Univ, Inst Med Mycol, Tokyo 173, Japan
基金
日本学术振兴会;
关键词
Anti-N10; antibody; disintegrin-like and metalloprotease with thrombospondin type 1 repeat motifs 13; dogs; von Willebrand factor 73; VON-WILLEBRAND-FACTOR; THROMBOTIC THROMBOCYTOPENIC PURPURA; FACTOR-CLEAVING PROTEASE; VONWILLEBRAND-FACTOR; FUNCTIONAL-CHARACTERIZATION; GLYCOPROTEIN-IB; COMPLEX; EXPRESSION; MULTIMERS; CLONING;
D O I
10.1177/1040638714523609
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
A disintegrin-like and metalloprotease with thrombospondin type 1 repeat motifs 13 (ADAMTS13) is a von Willebrand factor (vWF)-cleaving protease. Deficiencies in ADAMTS13 activity are known to cause thrombotic diseases in human beings. The present study evaluated whether the human ADAMTS13 activity enzyme-linked immunosorbent assay (ELISA) kit containing human vWF73 (a minimal substrate) and anti-N10 antibody (which specifically recognizes the decapeptide of the C-terminal edge of cleaved vWF by human ADAMTS13) is applicable to the measurement of canine plasma ADAMTS13 activity. Human vWF73 fused with a GST-tag and a His-tag (GST-hvWF73-His) was reacted with recombinant canine (rc)ADAMTS13, canine plasma, and human plasma, and then used in Western blotting using anti-N10 antibody. Linearity and intra- and interassay reproducibility of the human ADAMTS13 activity ELISA kit in canine plasma were further evaluated. Finally, plasma ADAMTS13 activity was measured in 13 healthy dogs and 6 dogs with bacteremia using the human ADAMTS13 activity ELISA kit. Cleaved products with a 28-kDa GST-hvWF73-His were detected specifically in rcADAMTS13 as well as in human ADAMTS13, and also in canine plasma by anti-N10 antibody, showing excellent linearity. Intra-assay coefficient of variation (CV) was 3.0-12.4%, and interassay CV was 11.5-12.5%. The ADAMTS13 activity was significantly lower in dogs with bacteremia than in healthy dogs (P = 0.0025). The current study revealed that the human ADAMTS13 activity ELISA kit is applicable for measurement of canine plasma ADAMTS13 activity to elucidate the pathology of thrombotic diseases in dogs.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 50 条
  • [1] Cyclosporin A Impairs the Secretion and Activity of ADAMTS13 (A Disintegrin and Metalloprotease with Thrombospondin Type 1 Repeat)
    Hershko, Klilah
    Simhadri, Vijaya L.
    Blaisdell, Adam
    Hunt, Ryan C.
    Newell, Jordan
    Tseng, Sandra C.
    Hershko, Alon Y.
    Choi, Jae Won
    Sauna, Zuben E.
    Wu, Andrew
    Bram, Richard J.
    Komar, Anton A.
    Kimchi-Sarfaty, Chava
    JOURNAL OF BIOLOGICAL CHEMISTRY, 2012, 287 (53) : 44361 - 44371
  • [2] ADAMTS13 INHIBITOR ASSESSMENT WITH THE HEMOSIL ACUSTAR ADAMTS13 ACTIVITY ASSAY
    Valsecchi, C.
    Mirabet, M.
    Mancini, I.
    Schiavone, L.
    Mane-Padros, D.
    Peyvandi, F.
    HAEMATOLOGICA, 2019, 104 : 23 - 24
  • [3] Identification of a functional exosite in the ADAMTS13 disintegrin-like domain
    de Groot, R.
    Ramroop, N.
    Bardhan, A.
    Crawley, J. T. B.
    Lane, D. A.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 963 - 963
  • [4] Essential role of the disintegrin-like domain in ADAMTS13 function
    de Groot, Rens
    Bardhan, Ajoy
    Ramroop, Nalisha
    Lane, David A.
    Crawley, James T. B.
    BLOOD, 2009, 113 (22) : 5609 - 5616
  • [5] Evaluation of an ADAMTS13 activity ELISA
    Butler, J.
    Butler, J. J.
    Malan, E.
    Clifford, J.
    Wheeler, M.
    Gan, E.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 563 - 563
  • [6] Evaluation of a commercial assay for ADAMTS13 activity measurement
    Thouzeau, Sandrine
    Capdenat, Sophie
    Stepanian, Alain
    Coppo, Paul
    Veyradier, Agnes
    THROMBOSIS AND HAEMOSTASIS, 2013, 110 (04) : 852 - 853
  • [7] Thrombospondin-1 as a modulator of ADAMTS13 activity.
    Palla, Roberta
    Rossana, Lombardi
    Zwicker, Jeffrey I.
    Lawler, Jack
    De Cristofaro, Raimondo
    Peyvandi, Flora
    BLOOD, 2007, 110 (11) : 1083A - 1084A
  • [8] The ADAMTS13 metalloprotease domain: roles of subsites in enzyme activity and specificity
    de Groot, Rens
    Lane, David A.
    Crawley, James T. B.
    BLOOD, 2010, 116 (16) : 3064 - 3072
  • [9] Findings from ADAMTS13 activity assay
    Kokame, K.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 6 - 6
  • [10] A sensitive enzyme-linked assay of ADAMTS13 antibodies for diagnosis of TTP
    Raoufi, M
    Zhou, W
    Guinto, E
    Grafos, N
    Ranzurmal, S
    Greenfield, RS
    Rand, J
    Tsai, HM
    BLOOD, 2005, 106 (11) : 164A - 165A