Expandable titanium cages in vertebral body replacement

被引:12
|
作者
Ulmar, B
Cakir, B
Huch, K
Puhl, W
Richter, M
机构
[1] Univ Ulm, Orthopad Klin Querschnittgelahmtenzentrum, D-89081 Ulm, Germany
[2] Univ Ulm, RKU, Ulm, Germany
来源
关键词
corporectomy; spinal fractures; spinal tumour; spinal metastasis;
D O I
10.1055/s-2004-820345
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: The aim of vertebral body replacement is the stabilisation and restoration of the anterior column of the spine with removal of the diseased region. We present our results of stabilisation, pain reduction and neurological improvement using vertebral-body replacement systems Methods: Between April 1997 and December 2002, 53 patients with malignant vertebral destruction or instability due to traumatic and osteoporotic fracture were treated. We evaluated the results after vertebrectomy and vertebral body replacement by using expandable titanium cages in a retrospective study. Results: The average follow-up time was 18.9 +/- 19.9 months. The mean operation time was 173.2 +/- 77.4 minutes. Intraoperatively, we saw no implant-related complications. Peri operatively, complications appeared in 18 patients (34.0%) 4 of them were severe, with 2 patients dying. in the total follow-up, 16 patients died, 10 of them (62.5%) due to tumour progression. Pain reduction was reported in 52.7%, neurological improvement in 48.0%. One patient had a loosening of his posterior instrumentation in the further follow-up due to tumour growth with dislocation of the cage and a deterioration of his neurological deficit. Conclusion: By using vertebral body replacement systems, sufficient stabilisation of the vertebral column, pain reduction and neurological improvement can be achieved with an acceptable perioperative risk.
引用
收藏
页码:449 / 455
页数:7
相关论文
共 50 条
  • [1] Complications associated with cervical vertebral body replacement with expandable titanium cages
    Brenke, Christopher
    Fischer, Sebastian
    Carolus, Anne
    Schmieder, Kirsten
    Ening, Genevieve
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 32 : 35 - 40
  • [2] Biomechanical comparison of expandable cages for vertebral body replacement in the cervical spine
    Kandziora, F
    Pflugmacher, R
    Schaefer, J
    Scholz, M
    Ludwig, K
    Schleicher, P
    Haas, NP
    [J]. JOURNAL OF NEUROSURGERY, 2003, 99 (01) : 91 - 97
  • [3] Biomechanical comparison of expandable cages for vertebral body replacement in the thoracolumbar spine
    Pflugmacher, R
    Schleicher, P
    Schaefer, J
    Scholz, M
    Ludwig, K
    Khodadadyan-Klostermann, C
    Haas, NP
    Kandziora, F
    [J]. SPINE, 2004, 29 (13) : 1413 - 1419
  • [4] A New Vertebral Body Replacement Strategy Using Expandable Polymeric Cages
    Liu, Xifeng
    Paulsen, Alex
    Giambini, Hugo
    Guo, Ji
    Miller, A. Lee, II
    Lin, Po-Chun
    Yaszemski, Michael J.
    Lu, Lichun
    [J]. TISSUE ENGINEERING PART A, 2017, 23 (5-6) : 223 - 232
  • [5] Torque forces of expandable titanium vertebral body replacement cages during expansion and subsidence in the osteoporotic lumbar spine
    Sircar, Krishnan
    Weber, Maximilian
    Walter, Sebastian G.
    Ott, Nadine
    Prescher, Andreas
    Eysel, Peer
    Kernich, Nikolaus
    [J]. CLINICAL BIOMECHANICS, 2024, 114
  • [6] Oligo poly (ethylene glycol) fumarate expandable cages for vertebral body replacement
    Liu, Xifeng
    Paulsen, Alex
    Giambini, Hugo
    Guo, Ji
    Miller, Alan, II
    Lin, Po-Chun
    Yaszemski, Michael
    Lu, Lichun
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [7] Use of titanium expandable vertebral cages in cervical corpectomy
    Burkett, Clinton J.
    Baaj, Ali A.
    Dakwar, Elias
    Uribe, Juan S.
    [J]. JOURNAL OF CLINICAL NEUROSCIENCE, 2012, 19 (03) : 402 - 405
  • [8] Reconstruction of large defects in vertebral osteomyelitis with expandable titanium cages
    Robinson, Yohan
    Tschoeke, Sven Kevin
    Kayser, Ralph
    Boehm, Heinrich
    Heyde, Christoph E.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) : 745 - 749
  • [9] Reconstruction of large defects in vertebral osteomyelitis with expandable titanium cages
    Yohan Robinson
    Sven Kevin Tschoeke
    Ralph Kayser
    Heinrich Boehm
    Christoph E. Heyde
    [J]. International Orthopaedics, 2009, 33 : 745 - 749
  • [10] THE USE OF ALLOGRAFT OR AUTOGRAFT AND EXPANDABLE TITANIUM CAGES FOR THE TREATMENT OF VERTEBRAL OSTEOMYELITIS
    Lu, Daniel C.
    Wang, Vincent
    Chou, Dean
    [J]. NEUROSURGERY, 2009, 64 (01) : 122 - 129