Multi-beam simultaneous transmit multi-zone (MB-STMZ) focusing method using modulated orthogonal codes for ultrasound imaging

被引:5
|
作者
Kim, BH [1 ]
Song, TK [1 ]
机构
[1] Sogang Univ, Dept Elect Engn, Ctr Med Solut Res, Seoul 100611, South Korea
关键词
ultrasound array imaging; MB-STMZ focusing method; pulse compression; coded imaging; orthogonal Golay codes; orthogonal chirps; GSNR; spatial resolution;
D O I
10.1117/12.535317
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, a novel method for simultaneous transmit multi-zone (STMZ) focusing along multiple scan lines using modulated orthogonal codes is presented. In this method, M mutually orthogonal Golay codes are transmitted along M respective directions to obtain M scan lines simultaneously, where each Golay code consists of M complementary sequences. This implies that along each scan direction M complementary sequences comprising one of the Golay code are to be fired sequentially. Therefore, total M transmit and receive (T/R) events are required to obtain M scan lines. In the proposed method, however, each complementary code is convolved with the sum of L orthogonal chirps that are focused at L different depths. Consequently, the proposed method requires M T/R events to obtain M scan lines with L transmit foci each, whereas ML T/R events are required in conventional pulse echo imaging. After M firings, first, the M orthogonal Golay codes are compressed separately, second, each compressed Golay signal is correlated with L respective orthogonal chirps. Finally, the L compressed chirp signals are independently focused and combined to provide the dynamically focused beams along M scan lines, each with multi-zone transmit foci. Experimental results with a 7.5MHz linear array, for M=L=2, showed that the proposed method can provide ultrasound images with higher frame rates and significantly improved SNR compared to conventional multi-zone focusing methods using short pulses.
引用
收藏
页码:315 / 323
页数:9
相关论文
共 5 条
  • [1] Orthogonal Quadratic Chirp Signals for Simultaneous Multi-Zone Focusing in Medical Ultrasound Imaging
    Yoon, Changhan
    Yoo, Yangmo
    Song, Tai-Kyong
    Chang, Jin Ho
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (05) : 1061 - 1069
  • [2] A post-compression based ultrasound imaging technique for simultaneous transmit multi-zone focusing
    Kim, Bae-Hyung
    Kim, Gi-Duck
    Song, Tai-Kyong
    ULTRASONICS, 2007, 46 (02) : 148 - 154
  • [3] A method for simultaneous multi-zone focusing along multiple scan lines using orthogonal codes and its application to multi-dimensional array imaging
    Kim, BH
    Song, TK
    2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 1725 - 1728
  • [4] Fast Three-Dimensional Ultrasound Cardiac Imaging Using Multi-Transmit Beam Forming: A Simulation Study
    Tong, Ling
    Ortega, Alejandra
    Gao, Hang
    D'hooge, Jan
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1448 - 1451
  • [5] Generation of an ultralong pure longitudinal magnetization needle with high axial homogeneity using an azimuthally polarized beam modulated by pure multi-zone plate phase filter
    Yan, Weichao
    Nie, Zhongquan
    Zhang, Xueru
    Wang, Yuxiao
    Song, Yinglin
    JOURNAL OF OPTICS, 2017, 19 (08)