A validation study of a smartphone application for heart rate variability assessment in asymptomatic adults

被引:0
|
作者
Gambassi, Bruno Bavaresco [1 ,2 ]
Neves, Victor Ribeiro [1 ,3 ]
Alves Brito, Einstein Zeus [1 ,4 ]
da Silva Fernandes, Danilo Sobral [1 ,4 ,5 ]
Sa, Camila Almeida [1 ,4 ,5 ]
Rocha Nogueira, Raquel Moraes [2 ]
Furtado Almeida, Fabiano de Jesus [11 ]
de Araujo Cavalcanti, Pedro Augusto [4 ]
Gomes Goncalves e Silva, Daniela Conceicao [1 ,6 ]
Neto, Danilo Sobreira [1 ,5 ,7 ]
de Souza Mesquita, Fabricio Olinda [1 ,4 ,6 ,7 ]
Gaspar Novais, Tania Maria [2 ]
Matias de Souza, Vania de Fatima [8 ]
Cerqueira Oliveira, Antonio Carlos [1 ,9 ]
Leite, Richard Diego [10 ]
Schwingel, Paulo Adriano [1 ,3 ,6 ]
机构
[1] Univ Pernambuco UPE, Lab Pesquisas Desempenho Humano LAPEDH, BR-56328900 Petrolina, PE, Brazil
[2] Univ Ceuma CEUMA, Programa Posgrad Gestao Programas & Serv Saude MG, BR-65075120 Sao Luis, MA, Brazil
[3] UPE, Programa Posgrad Reabilitacao & Desempenho Func P, BR-56328900 Petrolina, PE, Brazil
[4] Fac Tecnol Inspirar INSPIRAR, Curso Posgrad Fisioterapia Traumato Ortopedia & E, BR-56302280 Petrolina, PE, Brazil
[5] Inst Valler Med Integrada VALLER, Dept Med Esport, BR-48903055 Juazeiro, BA, Brazil
[6] Univ Pernambuco, Programa Posgrad Ciencias Saude PPGCS, BR-50100130 Recife, PE, Brazil
[7] Hosp Univ Univ Fed Vale Sao Francisco HU UNIVASF, Empresa Brasileira Serv Hosp EBSERH, BR-56304205 Petrolina, PE, Brazil
[8] Univ Estadual Maringa UEM, Dept Educ Fis DEF, BR-87020900 Maringa, Parana, Brazil
[9] Univ Fed Bahia UFBA, Complexo Hosp Univ Prof Edgard Santos HUPES, BR-40301155 Salvador, BA, Brazil
[10] Univ Fed Espirito Santo UFES, Ctr Educ Fis & Desportos CEFD, Lab Forca & Condicionamento, BR-2907591 Vitoria, ES, Brazil
[11] Univ Ceuma CEUMA, BR-65075120 Sao Luis, Maranhao, Brazil
来源
关键词
Autonomic nervous system; heart rate; electrocardiography; mobile applications; RATE MONITOR; VALIDITY; INTERVALS; SYSTEM;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Assessment of heart rate variability (HRV) is an effective non-invasive tool to obtain data on cardiac autonomic modulation and may be assessed by a range of devices, including mobile applications. Objective: This study aimed to validate a smartphone application by comparingthe R-R intervals (RRi) obtained by the app with a classic electrocardiogram (ECG)-derived reference condition Methods: Fifteen asymptomatic adults (24.9 +/- 3.4 years) underwent an orthostatic challenge during which RRi were simultaneously recorded by a freeware smartphone application and by an ECG recorder. Pearson correlation coefficients (r) and coefficients of determination (r(2)) were calculated to determine the degree of association between the two electronic devices. Two-way repeated measures analysis of variance and Bland-Altman analysis were used to calculate the measurement consistency and agreement, respectively, between the two methods. Effect size was also used to estimate the magnitude of the differences. Results: The number of RRi from asymptomatic adults recorded by the ECG and by the free smartphone application was similar at rest in supine position (13,149 vs. 13,157; P = 0.432) and during orthostatic challenge (10,666 vs. 10,664 P = 0.532). RRi in milliseconds from both devices presented a near perfect correlation in the supine position (r = 0.999; Confidence Interval [CI] at 95%: 0.999-0.999; P < 0.0001) and during orthostatic challenge (r = 0.988; 95% CI: 0.988-0.989; P < 0.0001). A negative bias of -0.526 milliseconds (95% limits of agreement [LoA] from -4.319 to 3.266 milliseconds) was observed in supine position between ECG and the smartphone application. On the other hand, a positive bias of 0.077 milliseconds (95% LoA from -10.090 to 10.240 milliseconds) during the orthostatic challenge was observed. Conclusions: Our results cross-validated a freeware smartphone application with the ECG-derived reference condition for asymptomatic adults at rest in the supine position and during orthostatic challenge.
引用
收藏
页码:219 / 229
页数:11
相关论文
共 50 条
  • [1] Validation of Photoplethysmography Using a Mobile Phone Application for the Assessment of Heart Rate Variability in the Context of Heart Rate Variability-Biofeedback
    van Dijk, Willeke
    Huizink, Anja C.
    Oosterman, Mirjam
    Lemmers-Jansen, Imke L. J.
    de Vente, Wieke
    PSYCHOSOMATIC MEDICINE, 2023, 85 (07): : 568 - 576
  • [2] Validity of a Smartphone Application in Calculating Measures of Heart Rate Variability
    Himariotis, Andreas T.
    Coffey, Kyle F.
    Noel, Sabrina E.
    Cornell, David J.
    SENSORS, 2022, 22 (24)
  • [3] Measuring Heart Rate and Heart Rate Variability with Smartphone Camera
    Qiao, Donghao
    Zulkernine, Farhana
    Masroor, Raihan
    Rasool, Roshaan
    Jaffar, Nauman
    2021 22ND IEEE INTERNATIONAL CONFERENCE ON MOBILE DATA MANAGEMENT (MDM 2021), 2021, : 248 - 249
  • [4] Central serous chorioretinopathy and heart rate variability analysis with a smartphone application
    Keigo Takeshima
    Koji Tanaka
    Ryusaburo Mori
    Yu Wakatsuki
    Hajime Onoe
    Takuya Sakakibara
    Yorihisa Kitagawa
    Hiroyuki Nakashizuka
    Norihiro Tsuchiya
    Scientific Reports, 10
  • [5] Accuracy of a Smartphone Application to Measure Heart Rate Variability in Adult Females
    Nicks, Clayton
    Early, Kate
    Tyo, Brian
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 187 - 187
  • [6] Central serous chorioretinopathy and heart rate variability analysis with a smartphone application
    Takeshima, Keigo
    Tanaka, Koji
    Mori, Ryusaburo
    Wakatsuki, Yu
    Onoe, Hajime
    Sakakibara, Takuya
    Kitagawa, Yorihisa
    Nakashizuka, Hiroyuki
    Tsuchiya, Norihiro
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [7] Heart rate and heart rate variability measuring system by using Smartphone
    1600, Institute of Electrical and Electronics Engineers Inc., United States
  • [8] Wrist-Based Photoplethysmography Assessment of Heart Rate and Heart Rate Variability: Validation of WHOOP
    Bellenger, Clint R.
    Miller, Dean
    Halson, Shona L.
    Roach, Greg
    Sargent, Charli
    SENSORS, 2021, 21 (10)
  • [9] Validation of a Standalone Smartphone Application for Measuring Heart Rate Using Imaging Photoplethysmography
    Poh, Ming-Zher
    Poh, Yukkee C.
    TELEMEDICINE AND E-HEALTH, 2017, 23 (08) : 678 - 683
  • [10] VALIDATION OF SMARTPHONE FREE HEART RATE MONITORING APPLICATION DURING TREADMILL EXERCISE
    Jaafar, Zulkarnain
    Murugan, Aravind Kumar
    REVISTA BRASILEIRA DE MEDICINA DO ESPORTE, 2019, 25 (02) : 112 - 115