Correction to BrainSCAN central axis dose calculations for 6-MV photon beams to lung with lateral electron disequilibrium

被引:2
|
作者
Geyer, Peter
Blank, Hilbert
Zips, Daniel
Alheit, Horst
机构
[1] Tech Univ Dresden, Clin & Policlin Radiotherapy & Radiat Oncol, Univ Clin Carl Gustav Carus, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Dept Radiotherapy & Radiooncol, Fac Med, D-01307 Dresden, Germany
关键词
photon beams; lung dose correction; lateral electron disequilibrium; primary dose;
D O I
10.1016/j.ijrobp.2006.03.067
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop and evaluate a correction method for lateral electron disequilibrium and tissue inhomogeneities in lung tissues applicable to the BrainSCAN treatment planning system. Methods and Materials: Four noncoplanar 6-MV photon beams with different beam diameters were applied to the right lung of a thorax phantom. The measured/calculated dose value ratio was evaluated as a function of a parameter that describes the degree of the lateral electron disequilibrium based on the primary dose. Results: The dose ratio showed a clearcut linear dependency on the disequilibrium parameter. Applying the proposed correction method, only minor differences between the measured and calculated doses were found for lesions > 1cm. However, for lesions < 1cm surrounded by lung tissue the difference was <= 15%. Conclusion: The data have indicated a relevant magnitude of the correction factor only for lung lesions < 1cm. (c) 2006 Elsevier Inc.
引用
收藏
页码:S102 / S107
页数:6
相关论文
共 15 条
  • [1] PRIMARY DOSE IN PHOTON BEAMS WITH LATERAL ELECTRON DISEQUILIBRIUM
    NIZIN, PS
    CHANG, XS
    MEDICAL PHYSICS, 1991, 18 (04) : 744 - 748
  • [2] Monte Carlo dose calculations for a 6-MV photon beam in a thorax phantom
    Farajollahi A.
    Mesbahi A.
    Radiation Medicine, 2006, 24 (4): : 269 - 276
  • [3] High-resolution assessment of dose calculations in small MV photon beams on and off central axis
    Biasi, G.
    Hardcastle, N.
    Petasecca, M.
    Guatelli, S.
    Perevertaylo, V. L.
    Rosenfeld, A. B.
    Kron, T.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S946 - S947
  • [4] INVESTIGATION OF THE RELATIVE SURFACE DOSE FROM LIPOWITZ-METAL TISSUE COMPENSATORS FOR 24-MV AND 6-MV PHOTON BEAMS
    CARDARELLI, GA
    RAO, SN
    CAIL, D
    MEDICAL PHYSICS, 1991, 18 (02) : 282 - 287
  • [5] ACCURACY OF LUNG DOSE CALCULATIONS FOR LARGE-FIELD IRRADIATION WITH 6-MV X-RAYS
    ELKHATIB, E
    BATTISTA, JJ
    MEDICAL PHYSICS, 1986, 13 (01) : 111 - 116
  • [7] A Simple Source Model for 6 MV Flattening Filter Free Photon Beams Monte Carlo Dose Calculations
    Ezzati, Ahad Ollah
    Studenski, Matthew T.
    Jamshidi, Negin
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2021, 18 (07) : 791 - 798
  • [8] A Simple Source Model for 6 MV Flattening Filter Free Photon Beams Monte Carlo Dose Calculations
    Matthew T. Ahad Ollah Ezzati
    Negin Studenski
    Physics of Particles and Nuclei Letters, 2021, 18 : 791 - 798
  • [9] Validation of GEANT4 simulations for percentage depth dose calculations in heterogeneous media by using small photon beams from the 6-MV Cyberknife: Comparison with photon beam dosimetry with EBT2 film
    Chung Il Lee
    Sei-Chul Yoon
    Jae Won Shin
    Seung-Woo Hong
    Tae Suk Suh
    Kyung Joo Min
    Sang Deok Lee
    Su Mi Chung
    Jae-Yong Jung
    Journal of the Korean Physical Society, 2015, 66 : 1308 - 1316
  • [10] Validation of GEANT4 simulations for percentage depth dose calculations in heterogeneous media by using small photon beams from the 6-MV Cyberknife: Comparison with photon beam dosimetry with EBT2 film
    Lee, Chung Il
    Yoon, Sei-Chul
    Shin, Jae Won
    Hong, Seung-Woo
    Suh, Tae Suk
    Min, Kyung Joo
    Lee, Sang Deok
    Chung, Su Mi
    Jung, Jae-Yong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 66 (08) : 1308 - 1316