Investigations of the proximity effect for pollutants in the indoor environment

被引:66
|
作者
McBride, SJ [1 ]
Ferro, AR [1 ]
Ott, WR [1 ]
Switzer, P [1 ]
Hildemann, LM [1 ]
机构
[1] Stanford Univ, Dept Stat, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
exposure; indoor air quality; indoor modeling; particles; proximity effect; real-time measurement methods;
D O I
10.1038/sj.jea.7500057
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
More than a dozen indoor air quality studies have reported a large discrepancy between concentrations measured by stationary indoor monitors (SIMs) and personal exposure monitors (PEMs). One possible cause of this discrepancy is a source proximity effect, in which pollutant sources close to the respondent cause elevated and highly variable exposures. This paper describes three sets of experiments in a home using real-time measurements to characterize and quantify the proximity effect relative to a fixed distant location analogous to a SIM. In the first set of experiments, using sulfur hexafluoride (SF6) as a continuously emitting tracer pollutant From a point source, measurements of pollutant concentrations were made at different distances from the source under different air exchange rates and source strengths. A second set of experiments used a continuous point source of carbon monoxide (CO) tracer pollutant and an army of high time resolution monitors to collect simultaneous concentration readings at different locations in the room. A third set of experiments measured particle count density and particle-bound polycyclic aromatic hydrocarbon (PAH) concentrations emitted from a continuous particle point source tan incense stick) using two particle counters and two PAH monitors, and included human activity periods both before and during the source emission period. Results from the SF6 and CO experiments show that while the source is emitting, a source proximity effect can be seen in the increases in the mean and median and in the variability of concentrations closest to the source, even at a distance of 2.0 m from the source under certain settings of air exchange rate and source strength. CO concentrations at locations near the source were found to be higher and more variable than the predictions of the mass balance model. For particles emitted from the incense source, a source proximity effect was evident for the fine particle sizes (0.3 to 2.5 mu m) and particle-bound PAH up to at least 1.0 m from the source. Analysis of spatial and temporal patterns in the data for the three tracer pollutants reveal marked transient elevations of concentrations as seen by the monitor, referred to as "microplumes," particularly at locations close to the source. Mixing patterns in the room show complex patterns and directional effects, as evidenced by the variable intensity of the microplume activity at different locations. By characterizing the spatial and temporal variability of pollutant concentrations in the home, the proximity effect can be quantified, leading to improved indoor monitoring designs and models of human exposure to air pollutants.
引用
收藏
页码:602 / 621
页数:20
相关论文
共 50 条
  • [1] Investigations of the proximity effect for pollutants in the indoor environment
    SANDRA J MCBRIDE
    ANDREA R FERRO
    WAYNE R OTT
    PAUL SWITZER
    LYNN M HILDEMANN
    Journal of Exposure Science & Environmental Epidemiology, 1999, 9 : 602 - 621
  • [2] Measuring and Modeling the Residential Proximity Effect: Investigating Localized Dispersion of Indoor Air Pollutants
    Klepeis, N.
    Ott, W.
    Hildemann, L.
    Cheng, K.
    Acevedo-Bolton, V
    Jiang, R.
    EPIDEMIOLOGY, 2008, 19 (06) : S222 - S222
  • [3] A marked point process model for the source proximity effect in the indoor environment
    McBride, SJ
    JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 2002, 97 (459) : 683 - 691
  • [4] Research on indoor environment pollutants and controlling
    Liu, Jun
    Zhuo, Yuguo
    Ma, Jinxiang
    SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 251 - 253
  • [5] Monitoring of the Inorganic Pollutants in Built Indoor Environment
    Vasile, Vasilica
    Dima, Alina
    Ion, Mihaela
    REVISTA DE CHIMIE, 2017, 68 (01): : 85 - 89
  • [6] METHODS FOR ASSESSING BIOLOGICAL POLLUTANTS IN THE INDOOR ENVIRONMENT
    BINNIE, PWH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 198 : 21 - I&EC
  • [7] Effect of Environmental Pollutants on Taste Composition Based on Electroencephalography Signal Analysis in an Indoor Environment
    Chandran, Kalyana Sundaram
    Perumalsamy, Marichamy
    EKOLOJI, 2018, 27 (106): : 787 - 792
  • [8] Occurrence, Dynamics and Reactions of Organic Pollutants in the Indoor Environment
    Salthammer, Tunga
    Bahadir, Muefit
    CLEAN-SOIL AIR WATER, 2009, 37 (06) : 417 - 435
  • [9] Assessing Human Exposure to Organic Pollutants in the Indoor Environment
    Salthammer, Tunga
    Zhang, Yinping
    Mo, Jinhan
    Koch, Holger M.
    Weschler, Charles J.
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2018, 57 (38) : 12228 - 12263
  • [10] PROBLEMS, RELATED TO THE OCCURRENCE OF ORGANIC POLLUTANTS IN THE INDOOR ENVIRONMENT
    KLIEST, JJG
    BLOEMEN, HJT
    TOXICOLOGY AND INDUSTRIAL HEALTH, 1990, 6 (05) : 117 - 131