Ultraviolet protection factor of fabrics: comparison of laboratory and field-based measurements

被引:20
|
作者
Gambichler, T [1 ]
Hatch, KL
Avermaete, A
Bader, A
Herde, M
Altmeyer, P
Hoffmann, K
机构
[1] Ruhr Univ Bochum, Dept Dermatol, Bochum, Germany
[2] Univ Arizona, Coll Agr & Life Sci, Tucson, AZ USA
关键词
apparel textiles; clothing; photoprotection; skin cancer prevention; spore film; sun exposure; UV radiation;
D O I
10.1034/j.1600-0781.2001.00739.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background/purpose: Spectrophotometry has become an accepted laboratory-based method for the determination of the ultraviolet protection factor (UPF) of fabrics. However, the validity of the UPF determined in the laboratory has been a controversial issue with regard to its significance in the field. To compare UPF values obtained by spectrophotometry, determination of the minimal erythema dose (MED), and biological dosimetry, we conducted laboratory and field-based measurements on various fabric materials. Methods: One cotton, two viscose, and two polyester fabrics were enrolled into the study. Spectrophotometric (SP) testing was performed in accordance with the European standard. In vivo 'on skin' (IV) testing on human subjects was performed with and without fabric protection. For determination of NIED, a solar-simulator was used. In another part of the study, biological dosimetry (BD) testing was employed for laboratory testing with solar-simulated radiation (laboratory BD testing) as well as field-based measurements with natural sunlight in stationary (stationary BD testing) and 'real life' exposure situations (mobile subject BD testing). For field-based measurements one light-weight polyester fabric was selected. Results: The differences of the mean UPF values obtained by the laboratory-based methods were significant (MANOVA; P = 0.05), except for fabric no. 2 (MANOVA; P = 0.097). In 4 of the 5 fabrics tested, UPF values obtained by IV testing were significantly lower than those obtained by SP testing (t-test; P = 0.05). In 3 fabrics, SP testing revealed significantly higher UPF values in comparison to laboratory BD testing (t-test; P = 0.05). The differences of UPF values obtained by the laboratory and field-based measurements employed for the lightweight polyester fabric were significant (ANOVA; P = 0.05). In comparison to SP testing (UPF 3.8), stationary BD testing resulted in significantly lower (UPF 3.5) and mobile subject BD testing in a significantly higher UPF of 4.4 (t-test; P = 0.05). The UPF obtained by mobile subject BD testing differed significantly from the UPF obtained by stationary BD testing (t-test; P = 0.05). Conclusions: Comparison of the presented methods indicates that IV testing generally results in lower UPF values. By contrast BD testing in 'real life' exposure situations reveals relatively high UPF values. Although an overestimation of the spectrophotometrically measured UPF has been observed in comparative laboratory testing, UPF values obtained by field-based measurements are in relatively good agreement, or even surpass UPF values obtained by spectrophotometry. It is, therefore, suggested that SP testing provides 'safe' UPF values which may be also valid in extreme real exposure situations. Biological UV dosimetry is, however, a promising alternative method for UPF testing: the test is easily performed in realistic exposure situations, the test is relatively inexpensive, and the measurements are valid.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 50 条
  • [1] Field-based measurements of personal erythemal ultraviolet exposure through a common summer garment
    Parisi, AV
    Kimlin, MG
    Mulheran, L
    Meldrum, LR
    Randall, C
    PHOTODERMATOLOGY PHOTOIMMUNOLOGY & PHOTOMEDICINE, 2000, 16 (03) : 134 - 138
  • [2] Comparison of laboratory- and field-based exercise tests for COPD: a systematic review
    Fotheringham, Iain
    Meakin, Georgina
    Punekar, Yogesh Suresh
    Riley, John H.
    Cockle, Sarah M.
    Singh, Sally J.
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2015, 10 : 625 - 643
  • [3] COMPARISON OF PHYSIOLOGICAL AND SYMPTOM OUTCOMES TO LABORATORY AND FIELD-BASED EXERCISE TESTS IN PAH
    Ganderton, L.
    Gain, K.
    Fowler, R.
    Gabbay, E.
    Jenkins, S.
    RESPIROLOGY, 2013, 18 : 75 - 75
  • [4] Comparison of Lab-Based and Field-Based Measurements of Overhand Throwing Product Scores
    Webster, E. Kipling
    MacLellan, Michael J.
    Garn, Alex C.
    JOURNAL OF SPORT & EXERCISE PSYCHOLOGY, 2020, 42 : S26 - S26
  • [5] Ultraviolet protection factor of hemp/filament hybrid yarn knitted fabrics
    Ultravijolični zaščitni faktor pletiv, izdelanih iz konopljenofilamentne hibridne preje
    Stanković, Snežana (stankovic@tmf.bg.ac.rs), 1600, University of Ljubljana (60):
  • [6] Are Laboratory And Field-based Hamstring Strength Tests Correlated?
    Wakefield, Kaela J.
    Lovell, Ric
    Whalan, Matthew D.
    Sampson, John A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 447 - 447
  • [7] Ultraviolet refractometry using field-based light scattering spectroscopy
    Fu, Dan
    Choi, Wonshik
    Sung, Yongjin
    Oh, Seungeun
    Yaqoob, Zahid
    Park, Yongkeun
    Dasari, Ramachandra R.
    Feld, Michael S.
    OPTICS EXPRESS, 2009, 17 (21): : 18878 - 18886
  • [8] Ultraviolet Protection Factor of Gray-state Plain Cotton Knitted Fabrics
    Stankovic, Snezana B.
    Popovic, Dusan
    Poparic, Goran B.
    Bizjak, Mateja
    TEXTILE RESEARCH JOURNAL, 2009, 79 (11) : 1034 - 1042
  • [9] Simulating locational error in field-based measurements of reflectance
    Atkinson, PM
    GEOENV I - GEOSTATISTICS FOR ENVIRONMENTAL APPLICATIONS, 1997, 9 : 297 - 308
  • [10] Field-based measurements of volcanic ash resuspension by wind
    Del Bello, E.
    Taddeucci, J.
    Merrison, J. P.
    Rasmussen, K. R.
    Andronico, D.
    Ricci, T.
    Scarlato, R.
    Iversen, J. J.
    EARTH AND PLANETARY SCIENCE LETTERS, 2021, 554