Differential scanning calorimetry study of glass transition in frozen starch gels

被引:30
|
作者
Tananuwong, K [1 ]
Reid, DS [1 ]
机构
[1] Univ Calif Davis, Dept Food Sci & Technol, Davis, CA 95616 USA
关键词
starch; glass transition; differential scanning calorimetry; gelatinization; annealing;
D O I
10.1021/jf049960l
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The effects of initial water content, maximum heating temperature, amylopectin crystallinity type, and annealing on the glass transition of starch gels were studied by differential scanning calorimetry (DSC). The glass transition temperatures of the frozen gels measured as the onset (T-g,T-onset*) or midpoint temperature (T-g,T-midpoint*), heat capacity change during the glass transition (DeltaC(p)), unfrozen water of starch gels, and additional unfrozen water (AUW) arising from gelatinization were reported. The results show that T-g,T-onset* and T-g,T-midpoint* of the partially gelatinized gels are independent of the initial water content, while both of the T-g* values of the fully gelatinized gel increase as the initial water content increases. These observations might result from the difference in the level of structural disruption associated with different heating conditions, resulting in different gel structures as well as different concentrations of the sub-T-g unfrozen matrix. The amylopectin crystallinity type does not greatly affect T-g,T-onset* and T-g,T-midpoint* of the gels. Annealing at a temperature near T-g,T-onset* increases both T-g,T-onset* and T-g,T-midpoint* of the gels, possibly due to an increase in the extent of the freeze concentration as evidenced by a decrease in AM Annealing results in an increase in the DeltaC(p) value of the gels, presumably due to structural relaxation. A devitrification exotherm may be related to AM The annealing process decreases AUW, thus also decreasing the size of the exotherm.
引用
收藏
页码:4308 / 4317
页数:10
相关论文
共 50 条
  • [1] A DIFFERENTIAL SCANNING CALORIMETRY STUDY OF GLASS AND MELTING TRANSITIONS IN STARCH SUSPENSIONS AND GELS
    LIU, H
    LELIEVRE, J
    CARBOHYDRATE RESEARCH, 1991, 219 : 23 - 32
  • [2] Subzero Glass Transition of Waxy Maize Starch Studied by Differential Scanning Calorimetry
    Sang, Yijun
    Alavi, Sajid
    Shi, Yong-Cheng
    STARCH-STARKE, 2009, 61 (12): : 687 - 695
  • [3] Study of the glass transition in amorphous Se by differential scanning calorimetry
    Abu-Sehly, A. A.
    Abu El-Oyoun, M.
    Elabbar, A. A.
    THERMOCHIMICA ACTA, 2008, 472 (1-2) : 25 - 30
  • [4] Glass transition of anhydrous starch by fast scanning calorimetry
    Monnier, Xavier
    Maigret, Jean-Eudes
    Lourdin, Denis
    Saiter, Allisson
    CARBOHYDRATE POLYMERS, 2017, 173 : 77 - 83
  • [5] Glass Transition Parameters of Polyisoprene Rubbers: Differential Scanning Calorimetry Study
    N. Makhiyanov
    M. N. Khasanov
    Polymer Science, Series A, 2021, 63 : 220 - 227
  • [6] Glass Transition Parameters of Polyisoprene Rubbers: Differential Scanning Calorimetry Study
    Makhiyanov, N.
    Khasanov, M. N.
    POLYMER SCIENCE SERIES A, 2021, 63 (03) : 220 - 227
  • [7] Modulated differential scanning calorimetry in the glass transition region
    Boller, A
    Schick, C
    Wunderlich, B
    THERMOCHIMICA ACTA, 1995, 266 : 97 - 111
  • [8] GLASS TRANSITION MEASUREMENTS ON POLYSTYRENE BY DIFFERENTIAL SCANNING CALORIMETRY
    LAMBERT, A
    POLYMER, 1969, 10 (05) : 319 - &
  • [9] Determination of glass transition temperature by differential scanning calorimetry
    Kimura, N
    Aizawa, K
    Nishio, Y
    Suzuki, H
    KOBUNSHI RONBUNSHU, 1996, 53 (12) : 866 - 868
  • [10] DIFFERENTIAL SCANNING CALORIMETRY STUDIES ON THE CRYSTALLINITY OF AGING WHEAT-STARCH GELS
    LONGTON, J