Controlled fluorescence quenching by antibody-conjugated graphene oxide to measure tau protein

被引:36
|
作者
Huang, Ao [1 ]
Zhang, Luning [1 ]
Li, Weiwei [1 ]
Ma, Zeyu [1 ]
Shuo, Shi [1 ]
Yao, Tianming [1 ]
机构
[1] Tongji Univ, Sch Chem Sci & Engn, 1239 Siping Rd, Shanghai 200092, Peoples R China
来源
ROYAL SOCIETY OPEN SCIENCE | 2018年 / 5卷 / 04期
基金
中国国家自然科学基金;
关键词
tau protein; Alzheimer's disease; biosensor; graphene oxide; immunoassay; LINKED-IMMUNOSORBENT-ASSAY; RESONANCE ENERGY-TRANSFER; ALZHEIMERS-DISEASE; MONOCLONAL-ANTIBODY; ULTRASENSITIVE DETECTION; HOMOGENEOUS IMMUNOASSAY; CEREBROSPINAL-FLUID; LABEL; SERS; BIOMARKERS;
D O I
10.1098/rsos.171808
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We report an ultrasensitive immunoassay for tau protein-a keymarker of Alzheimer's disease. This sensing platform relies on graphene oxide (GO) surfaces conjugated with anti-human tau antibody to provide quantitative binding sites for the tau protein. The GO quenches standard fluorescein isothiocyanate labelled tau (tau-FITC) when tau protein and tau-FITC are both present and compete for the binding sites. This change in fluorescence signal can be used to quantitate tau protein. In contrast with traditional enzyme-linked immunosorbent assay (ELISA), our method does not require enzyme-linked secondary antibodies for protein recognition nor does it require an enzyme substrate for optical signal generation. This requires fewer reagents and has less systematic error than the antigen-antibody recognition steps in ELISA. Our method has a tau protein detection limit of 0.14 pmol ml(-1) in buffer. This approach could be developed into a promising biosensor for the detection of tau protein and may be useful in the clinical diagnosis of tau-induced neurodegeneration syndromes.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Quantitative Fluorescence Quenching on Antibody-conjugated Graphene Oxide as a Platform for Protein Sensing
    Huang, Ao
    Li, Weiwei
    Shi, Shuo
    Yao, Tianming
    SCIENTIFIC REPORTS, 2017, 7
  • [2] Quantitative Fluorescence Quenching on Antibody-conjugated Graphene Oxide as a Platform for Protein Sensing
    Ao Huang
    Weiwei Li
    Shuo Shi
    Tianming Yao
    Scientific Reports, 7
  • [3] Fluorescence Quenching of Dyes by Graphene Oxide
    V. A. Povedailo
    B. V. Ronishenko
    V. I. Stepuro
    D. A. Tsybulsky
    V. V. Shmanai
    D. L. Yakovlev
    Journal of Applied Spectroscopy, 2018, 85 : 605 - 610
  • [4] Fluorescence Quenching of Dyes by Graphene Oxide
    Povedailo, V. A.
    Ronishenko, B., V
    Stepuro, V., I
    Tsybulsky, D. A.
    Shmanai, V. V.
    Yakovlev, D. L.
    JOURNAL OF APPLIED SPECTROSCOPY, 2018, 85 (04) : 605 - 610
  • [5] Multiplexed protein analysis using encoded antibody-conjugated microbeads
    Theilacker, Nora
    Roller, Eric E.
    Barbee, Kristopher D.
    Franzreb, Matthias
    Huang, Xiaohua
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2011, 8 (61) : 1104 - 1113
  • [6] Photoluminescence and Fluorescence Quenching of Graphene Oxide: A Review
    Xiao, Xinzhe
    Zhang, Yumin
    Zhou, Lei
    Li, Bin
    Gu, Lin
    NANOMATERIALS, 2022, 12 (14)
  • [7] Study on the fluorescence quenching of ZnO by graphene oxide
    Li J.-T.
    Yang J.
    Zhou S.-H.
    Wang S.-H.
    Liu K.-L.
    Xu C.-X.
    Optoelectronics Letters, 2016, 12 (1) : 35 - 38
  • [8] Study on the fluorescence quenching of ZnO by graphene oxide
    理记涛
    杨静
    周思华
    王少辉
    刘奎立
    徐春祥
    OptoelectronicsLetters, 2016, 12 (01) : 35 - 38
  • [9] In Vivo Targeting and Imaging of Tumor Vasculature with Radiolabeled, Antibody-Conjugated Nano-Graphene
    Cai, W.
    Hong, H.
    Yang, K.
    Zhang, Y.
    Engle, J. W.
    Feng, L.
    Theuer, C. P.
    Barnhart, T. E.
    Liu, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S195 - S196
  • [10] In Vivo Targeting and Imaging of Tumor Vasculature with Radiolabeled, Antibody-Conjugated Nano-Graphene
    Zhang, Y.
    Yang, K.
    Hong, H.
    Engle, J.
    Feng, L.
    Theuer, C.
    Barnhart, T.
    Liu, Z.
    Cai, W.
    MEDICAL PHYSICS, 2012, 39 (06) : 3950 - 3950