Barriers in the implementation of the Resuscitation Guidelines: European survey of defibrillation techniques

被引:4
|
作者
Krawczyk, Pawel [1 ]
Kononowicz, Andrzej A. [2 ]
Andres, Janusz [1 ]
机构
[1] Jagiellonian Univ, Coll Med, Dept Anaesthesiol & Intens Care, Kopernika 17, PL-31501 Krakow, Poland
[2] Jagiellonian Univ, Coll Med, Dept Bioinformat & Telemed, Lazarza 16, PL-31530 Krakow, Poland
关键词
Defibrillation; Technique; Adhesive pads; Manual paddles; Cardiopulmonary resuscitation; Advanced life support; Monitoring; Coupling medium; HOSPITAL CARDIAC-ARREST; COUNCIL GUIDELINES; CHEST COMPRESSIONS; PROBABILITY; SURVIVAL;
D O I
10.1186/s13049-016-0219-2
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The European Resuscitation Council (ERC) Guidelines recommend providing chest compressions during defibrillator charging and using adhesive pads for defibrillation to increase the effectiveness of resuscitation. However, the most common defibrillation technique in each European country is unknown, as are the potential barriers in implementation of the guidelines. The aim of this study was to assess the techniques of defibrillation procedures performed by professional European healthcare providers and to estimate how frequently adhesive pads are used. Methods: We sent an online questionnaire to the ERC National Representatives that contained 12 questions regarding the techniques of defibrillation and monitoring heart rhythm during cardiac arrest. We also evaluated the frequency and indications of manual paddles use. Results: We collected questionnaires from 27 out of 33 invited ERC member countries. The response rate was 82 %. Seventeen (17/27; 63 %) declared the use of adhesive pads. The leading cause for not using adhesive pads was economic reason (9/17; 53 %). Some respondents declared resistance to using adhesive pads by healthcare providers or tradition connected with manual paddles use. We found three leading techniques of defibrillation with manual paddles: Charging paddles keeping them on the defibrillator during chest compressions being delivered (9/21; 43 %), Charging paddles keeping them on the patient chest during chest compressions being delivered (6/21; 29 %), Charging paddles on the patient chest without chest compressions (5/21; 24 %). Respondents from 11 countries declared the use of gel or electrode pastes during defibrillation with manual paddles. Discussion: This study collected preliminary data showing how defibrillation is performed in Europe. It revealed the recommeded techniques underuse and identyfied barriers in the Resuscitation Guidelines implementation. The survey should be open to a wider group of respondents. in each country in future. Conclusions: There are limitations and barriers in the implementation of the defibrillation technique guidelines. There are still countries where the use of adhesive pads is low due to economic and traditional reasons. There is a need for further efforts focused on guidelines implementation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Barriers in the implementation of the Resuscitation Guidelines: European survey of defibrillation techniques
    Paweł Krawczyk
    Andrzej A. Kononowicz
    Janusz Andres
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 24
  • [2] European Resuscitation Council Guidelines 2000 for automated external defibrillation
    Monsieurs, KG
    Handley, AJ
    Bossaert, LL
    MEDICINA CLINICA, 2002, 118 (11): : 421 - 422
  • [3] European Resuscitation Council Guidelines for Resuscitation 2015 Section 10. Education and implementation of resuscitation
    Greif, Robert
    Lockey, Andrew S.
    Conaghan, Patricia
    Lippert, Anne
    De Vries, Wiebe
    Monsieurs, Koenraad G.
    RESUSCITATION, 2015, 95 : 288 - 301
  • [4] EUROPEAN GUIDELINES ON RESUSCITATION
    WARDROPE, J
    MORRIS, F
    BRITISH MEDICAL JOURNAL, 1993, 306 (6892): : 1555 - 1556
  • [5] European guidelines on resuscitation
    Dick, W
    Bossaert, L
    Chamberlain, D
    LANCET, 1996, 347 (9014): : 1558 - 1558
  • [6] European Resuscitation Council Guidelines 2000 for automated external defibrillation - A statement from the Basic Life Support and Automated External Defibrillation Working Group and approved by the Executive Committee of the European Resuscitation Council
    Monsieurs, KG
    Handley, AJ
    Bossaert, LL
    RESUSCITATION, 2001, 48 (03) : 207 - 209
  • [7] Guidelines of the European Resuscitation Council 2000 on automated external defibrillation. A statement of the basic life support and automated external defibrillation working group as approved by the executive committee of the European Resuscitation Council
    Dick, WF
    ANAESTHESIST, 2002, 51 (06): : 482 - 484
  • [8] Guidelines in medicine: Implementation, approaches, barriers - A survey of Berlin GPs
    Kunz, A
    Gusy, B
    GESUNDHEITSWESEN, 2005, 67 (07) : 555 - 555
  • [9] European Resuscitation Council Guidelines for Resuscitation 2010 Section 3 Electrical therapies Automated external defibrillators, defibrillation, cardioversion and pacing
    Deakin, Charles D.
    Nolan, Jerry P.
    Sunde, Kjetil
    Koster, Rudolph W.
    RESUSCITATION, 2010, 81 (10) : 1293 - 1304
  • [10] European Resuscitation Council Guidelines for Resuscitation 2015 Section 2. Adult basic life support and automated external defibrillation
    Perkins, Gavin D.
    Handley, Anthony J.
    Koster, Rudolph W.
    Castren, Maaret
    Smyth, Michael A.
    Olasveengen, Theresa
    Monsieurs, Koenraad G.
    Raffay, Violetta
    Graesner, Jan-Thorsten
    Wenzel, Volker
    Ristagno, Giuseppe
    Soar, Jasmeet
    RESUSCITATION, 2015, 95 : 81 - 99