Second-generation three-dimensional reconstruction for rotational three-dimensional angiography

被引:43
|
作者
Bidaut, LM
Laurent, C
Piotin, M
Gailloud, P
Muster, M
Fasel, JHD
Rüfenacht, DA
Terrier, F
机构
[1] Univ Hosp Geneva, Lab Funct & Multidimens Imaging, Div Med Informat, CH-1211 Geneva 14, Switzerland
[2] Univ Hosp Geneva, Neuroradiol Unit, Div Radiodiagnost & Intervent Radiol, CH-1211 Geneva 14, Switzerland
[3] Univ Hosp Geneva, Dept Morphol, CH-1211 Geneva 14, Switzerland
[4] Univ Hosp Geneva, Dept Radiol, CH-1211 Geneva 14, Switzerland
关键词
digital subtraction angiography; technology; interventional procedures;
D O I
10.1016/S1076-6332(98)80244-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The purpose of this study was to assess the feasibility and accuracy of three-dimensional (3D) reconstruction techniques for digital subtraction angiography (DSA) in planning and evaluation of minimally invasive image-controlled therapy. Materials and Methods, Using a standard, commercially available system, the authors acquired DSA images and corrected them for inherent distortions. They designed and implemented parallel and multiresolution versions of cone-beam reconstruction techniques to reconstruct high-resolution targeted volumes in a short period of time. Testing was performed on anatomically correct, calibrated in vitro models of a cerebral aneurysm. These models were used with a pulsatile circulation circuit to allow for blood flow simulation during DSA, computed tomographic (CT) angiography, and magnetic resonance (MR) angiography image acquisitions. Results. The multiresolution DSA-based reconstruction protocol and its implementation allowed the authors to achieve reconstruction times and levels of accuracy for the volume measurement of the aneurysmal cavities that were considered compatible with actual clinical practice. Comparison with data obtained from other imaging modalities shows that, besides vascular tree depiction, the DSB-based true 3D technique provides volume estimates at least as good as those obtained from CT and MR angiography. Conclusion. The authors demonstrated the feasibility and potential of true 3D reconstruction for angiographic imaging with DSA. On the basis of the model testing, this work addresses both the timing and quantification equi-red to support minimally invasive image-controlled therapy.
引用
收藏
页码:836 / 849
页数:14
相关论文
共 50 条
  • [1] Three-dimensional reconstruction of the coronary sinus with rotational angiography
    Kofune, Masayoshi
    Watanabe, Ichiro
    Ashino, Sonoko
    Okumura, Yasuo
    Kawauchi, Kazunori
    Kofune, Tatsuya
    Ohkubo, Kimie
    Hashimoto, Kenichi
    Sugimura, Hidezou
    Nakai, Toshiko
    Hirayama, Atsushi
    [J]. CIRCULATION JOURNAL, 2008, 72 (06) : 1020 - 1021
  • [2] Three-dimensional reconstruction of the coronary sinus using rotational angiography
    Mansour, M
    Reddy, VY
    Singh, J
    Mela, T
    Rasche, V
    Ruskin, J
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (06) : 675 - 676
  • [3] Three-dimensional rotational angiography guidance for aneurysm surgery
    Raabe, Andreas
    Beck, Juergen
    Rohde, Stefan
    Berkefeld, Joachim
    Seifert, Volker
    [J]. JOURNAL OF NEUROSURGERY, 2006, 105 (03) : 406 - 411
  • [4] Three-dimensional rotational angiography in children with an aortic coarctation
    N. L. P. Starmans
    G. J. Krings
    M. M. C. Molenschot
    F. van der Stelt
    J. M. P. J. Breur
    [J]. Netherlands Heart Journal, 2016, 24 : 666 - 674
  • [5] Three-dimensional rotational angiography in peripheral endovascular interventions
    van den Berg, JC
    Moll, FL
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2003, 10 (03) : 595 - 600
  • [6] Three-dimensional rotational angiography in children with an aortic coarctation
    Starmans, N. L. P.
    Krings, G. J.
    Molenschot, M. M. C.
    van der Stelt, F.
    Breur, J. M. P. J.
    [J]. NETHERLANDS HEART JOURNAL, 2016, 24 (11) : 666 - 674
  • [7] Assessment of distortion in a three-dimensional rotational angiography system
    Bridcut, RR
    Winder, RJ
    Workman, A
    Flynn, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (891): : 266 - 270
  • [8] Three-dimensional rotational angiography in the diagnosis of cerebral aneurysms
    Capello, D
    Mavilio, N
    Allegretti, L
    Rosa, ML
    [J]. RIVISTA DI NEURORADIOLOGIA, 2003, 16 : 45 - 50
  • [9] The effect of a second-generation three-dimensional visualization system on laparoscopic dexterity
    Smith, SGT
    Brown, TJ
    Torkington, J
    Darzi, A
    [J]. BRITISH JOURNAL OF SURGERY, 2002, 89 : 93 - 93
  • [10] Three-dimensional digital angiography: New tool for simultaneous three-dimensional rendering of vascular and osseous information during rotational angiography
    Gailloud, P
    Oishi, S
    Carpenter, J
    Murphy, KJ
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (04) : 571 - 573