Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor

被引:0
|
作者
Restrepo, Ruben D. [1 ]
Karpenkop, Ido [2 ]
Liu, Katherine E. [3 ]
机构
[1] UT Hlth Sci Ctr San Antonio, Div Resp Care, San Antonio, TX 78229 USA
[2] Medtronic, Patient Monitoring, OEM Engn, Res & Dev, Jerusalem, Israel
[3] Medtronic, Sci Commun, Minimally Invas Therapies Grp, Minneapolis, MN USA
来源
关键词
END-TIDAL CO2; RESPIRATORY DEPRESSION; CAPNOMETRY DEVICE; NASAL CANNULA; GUIDELINES; EVENTS;
D O I
10.3791/61670
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Capnography is commonly used to monitor patient's ventilatory status. While sidestream capnography has been shown to provide a reliable assessment of end-tidal CO2 (ETCO2), its accuracy is commonly validated using commercial kits composed of a capnography monitor and its matching disposable nasal cannula sampling lines. The purpose of this study was to assess the compatibility and accuracy of cross-paired capnography sampling lines with a single portable bedside capnography monitor. A series of 4 bench tests were performed to evaluate the tensile strength, rise time, ETCO2 accuracy as a function of respiratory rate, and ETCO2 accuracy in the presence of supplemental O-2. Each bench test was performed using specialized, validated equipment to allow for a full evaluation of sampling line performance. The 4 bench tests successfully differentiated between sampling lines from different commercial sources and suggested that due to increased rise time and decreased ETCO2 accuracy, not all nasal cannula sampling lines provide reliable clinical data when cross-paired with a commercial capnography monitor. Care should be taken to ensure that any cross-pairing of capnography monitors and disposable sampling lines is fully validated for use across respiratory rates and supplemental O-2 flow rates commonly encountered in clinical settings.
引用
收藏
页码:1 / 18
页数:18
相关论文
共 13 条
  • [1] Capnography Sample Line Design and Oxygen Delivery Influence ETCO2 Accuracy
    Karpenkop, Ido
    ANESTHESIA AND ANALGESIA, 2018, 127 : 60 - 61
  • [2] A Comparison of Carbon Dioxide Elimination Measurements Between a Portable Indirect Calorimeter and Volumetric Capnography Monitor: An In Vitro Simulation
    Smallwood, Craig D.
    Martinez, Enid E.
    Mehta, Nilesh M.
    RESPIRATORY CARE, 2016, 61 (03) : 354 - 358
  • [3] Does the Addition of Oral Sampling Improve Waveform Capnography When Compared to Traditional Nasal Sampling in Open-Airway Patients?
    Schiappa, Michael
    Han, Michael D.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2024, 82 (10) : 1194 - 1202
  • [4] A leak in a capnography sampling line induced a difference between arterial and end-tidal CO2
    Horishita, T
    Minami, K
    ANESTHESIOLOGY, 2001, 95 (03) : 815 - 815
  • [5] An Evaluation of Portable Wet Bulb Globe Temperature Monitor Accuracy
    Cooper, Earl
    Grundstein, Andrew
    Rosen, Adam
    Miles, Jessica
    Ko, Jupil
    Curry, Patrick
    JOURNAL OF ATHLETIC TRAINING, 2017, 52 (12) : 1161 - 1167
  • [6] EVALUATION OF UAV AUTONOMOUS FLIGHT ACCURACY WHEN CLASSICAL NAVIGATION ALGORITHM IS USED
    Kikutis, Ramunas
    Stankunas, Jonas
    Rudinskas, Darius
    TRANSPORT, 2018, 33 (03) : 589 - 597
  • [7] Evaluation of the accuracy of shell elements when used for modelling masonry minaret structures under seismic loading
    Awla H.A.
    Karaton M.
    Taher N.R.
    Hamah Sor N.
    Arbili M.M.
    Asian Journal of Civil Engineering, 2023, 24 (7) : 2011 - 2018
  • [8] Design and evaluation of a portable PM2.5 monitor featuring a low-cost sensor in line with an active filter sampler
    Tryner, Jessica
    Quinn, Casey
    Windom, Bret C.
    Volckens, John
    ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, 2019, 21 (08) : 1403 - 1415
  • [9] CLINICAL ACCURACY EVALUATION OF FREESTYLE LIBRE FLASH GLUCOSE MONITORING SYSTEM WHEN USED BY CHILDREN AND YOUNG PEOPLE WITH DIABETES
    Campbell, F.
    Edge, J.
    Acerini, C.
    Hamilton-Shield, J.
    Moudiotis, C.
    Rahman, S.
    Randell, T.
    Smith, A.
    Trevelyan, N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A29 - A29
  • [10] Retrospective Evaluation of the Accuracy of Roche AccuChek Inform and Nova StatStrip Glucose Meters when Used on Critically Ill Patients
    Karon, Brad S.
    Blanshan, Chanse T.
    Deobald, Gayle R.
    Wockenfus, Amy M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 (12) : 828 - 832