Intracranial aneurysm stenting:: Follow-up with MR angiography

被引:51
|
作者
Loevblad, Karl-Olof
Yilmaz, Hasan
Chouiter, Amine
Ruiz, Diego San Millan
Abdo, German
Bijlenga, Philippe
de Tribolet, Nicolas
Ruefenacht, Daniel A.
机构
[1] Univ Hosp Geneva, Div Neuroradiol, Radiol Dept SRRI, CH-1211 Geneva 14, Switzerland
[2] Univ Hosp Geneva, Dept Neurosurg, CH-1211 Geneva, Switzerland
关键词
stent; MRA; aneurysm; artifact vessel;
D O I
10.1002/jmri.20642
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Intracranial stenting is increasingly being used to treat intracranial aneurysms and stenoses. We wanted to assess the utility of magnetic resonance angiography (MRA) in the follow-up of patients treated with various types of intracranial stents and to assess the utility of performing gadolinium-enhanced MRA. A total of 19 patients having undergone intracranial stenting for aneurysms were imaged by MRI at 1.5T. A total of 20 stents were placed in 19 patients. In addition to conventional T2 and diffusion-weighted MRI, 3D time-of-flight MRA was performed before and after contrast administration. In the case of metallic INX stents (N = 7), there was a signal drop at the level of the vessel which did not allow to evaluating the parent vessel, whereas this was visible in Nitinol stents (N = 8). Additionally a stent with a wire had a small artifact (N = 3)., Contrast administration also improved vessel lumen visualization. In the case of Nitinol stents, MRA can be used reliably demonstrate the vessel lumen after intracranial stenting. The use of postcontrast 3D time-of-flight imaging helps improve the intralumiinal definition.
引用
收藏
页码:418 / 422
页数:5
相关论文
共 50 条
  • [1] CONTRIBUTION OF MR-ANGIOGRAPHY TO THE DIAGNOSIS AND THE THERAPEUTIC INDICATION AND FOLLOW-UP OF INTRACRANIAL ANEURYSMS
    AUFFRAY, E
    DEKERSAINTGILLY, A
    HAVET, T
    SONIER, CB
    BUHE, T
    MANTOURA, J
    SZAPIRO, J
    JOURNAL OF NEURORADIOLOGY, 1994, 21 (01) : 17 - 29
  • [2] Transcranial Doppler Follow-Up after Intracranial Stenting
    Romano, Jose
    Yavagal, Dileep
    Cabrera, Frank A.
    Echevarria, Yosdely
    Koch, Sebastian
    NEUROLOGY, 2010, 74 (09) : A229 - A229
  • [3] Follow-up of endovascular aneurysm repair: Plain radiography, ultrasound, CT/CT angiography, MR imaging/MR angiography, or what?
    Kranokpiraksa, Pawanrat
    Kaufman, John A.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) : S27 - S36
  • [4] MR-ANGIOGRAPHY IN THE FOLLOW-UP OF INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS TREATED BY THE ENDOVASCULAR METHOD
    TOURNADE, A
    KRUPA, P
    TAJAHMADY, T
    OESTERLE, H
    SENGEL, C
    COURTHEOUX, P
    CERFON, JF
    STILHART, B
    COSCIA, S
    SROUR, R
    JOURNAL OF NEURORADIOLOGY, 1994, 21 (04) : 255 - 261
  • [5] Application of zero echo time MR angiography in follow-up of intracranial aneurysm remnant and in-stent lumen after embolization: a comparison study with digital subtraction angiography
    Song, Yan
    Qi, Peng
    Huang, Juan
    Jiao, Sheng
    Zhang, Jintao
    Wang, Daming
    Chen, Min
    ACTA RADIOLOGICA, 2020, 61 (04) : 480 - 486
  • [6] SMART coils for intracranial aneurysm embolization: Follow-up outcomes
    Sokolowski, Jennifer D.
    Ilyas, Adeel
    Buell, Thomas J.
    Taylor, Davis G.
    Chen, Ching-Jen
    Ding, Dale
    Raper, Daniel M. S.
    Liu, Kenneth C.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2019, 59 : 93 - 97
  • [7] Prevalence of Unruptured Intracranial Aneurysm on MR Angiography
    Jeon, Tae Yeon
    Jeon, Pyoung
    Kim, Keon Ha
    KOREAN JOURNAL OF RADIOLOGY, 2011, 12 (05) : 547 - 553
  • [8] Carotid stenting follow-up: Comparison of angiography, CT-angiography and duplex sonography
    Von Smekal, U
    Brassel, F
    Griewing, B
    Schminke, U
    Kirsch, M
    Al Ahmar, T
    RADIOLOGY, 1999, 213P : 488 - 488
  • [9] MR angiography at 3T versus digital subtraction angiography in the follow-up of intracranial aneurysms treated with detachable coils
    Majoie, CBLM
    Sprengers, ME
    van Rooij, WJJ
    Lavini, C
    Sluzewski, M
    van Rijn, JC
    den Heeten, GJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (06) : 1349 - 1356
  • [10] Diagnostic accuracy of 3D time-of-flight MR angiography compared with digital subtraction angiography for follow-up of coiled intracranial aneurysms: Influence of aneurysm size
    Deutschmann, H. A.
    Augustin, M.
    Simbrunner, J.
    Unger, B.
    Schoellnast, H.
    Fritz, G. A.
    Klein, G. E.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (04) : 628 - 634