Diagnostic performance of 18F-FDG PET/CT and whole-body diffusion-weighted imaging with background body suppression (DWIBS) in detection of lymph node and bone metastases from pediatric neuroblastoma

被引:31
|
作者
Ishiguchi, Hiroaki [1 ,2 ]
Ito, Shinji [1 ]
Kato, Katsuhiko [3 ]
Sakurai, Yusuke [1 ]
Kawai, Hisashi [1 ]
Fujita, Naotoshi [4 ]
Abe, Shinji [4 ]
Narita, Atsushi [5 ]
Nishio, Nobuhiro [5 ]
Muramatsu, Hideki [5 ]
Takahashi, Yoshiyuki [5 ]
Naganawa, Shinji [1 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Radiol, Nagoya, Aichi, Japan
[2] Toyohashi Municipal Hosp, Dept Radiol, Toyohashi, Aichi, Japan
[3] Nagoya Univ, Grad Sch Med, Dept Radiol & Lab Sci, Higashi Ku, 1-20 Daikominami 1 Chome, Nagoya, Aichi 4618673, Japan
[4] Nagoya Univ Hosp, Dept Radiol Technol, Nagoya, Aichi, Japan
[5] Nagoya Univ, Grad Sch Med, Dept Pediat, Nagoya, Aichi, Japan
基金
日本学术振兴会;
关键词
F-18-FDG PET/CT; Whole-body DWIBS; Neuroblastoma; Metastasis; MRI; SCINTIGRAPHY; I-123-MIBG; DIFFERENTIATION; MODALITY; CANCER; SIGNAL; TUMORS; CT;
D O I
10.1007/s12149-018-1254-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent many studies have shown that whole body "diffusion-weighted imaging with background body signal suppression" (DWIBS) seems a beneficial tool having higher tumor detection sensitivity without ionizing radiation exposure for pediatric tumors. In this study, we evaluated the diagnostic performance of whole body DWIBS and F-18-FDG PET/CT for detecting lymph node and bone metastases in pediatric patients with neuroblastoma. Subjects in this retrospective study comprised 13 consecutive pediatric patients with neuroblastoma (7 males, 6 females; mean age, 2.9 +/- 2.0 years old) who underwent both F-18-FDG PET/CT and whole-body DWIBS. All patients were diagnosed as neuroblastoma on the basis of pathological findings. Eight regions of lymph nodes and 17 segments of skeletons in all patients were evaluated. The images of I-123-MIBG scintigraphy/SPECT-CT, bone scintigraphy/SPECT, and CT were used to confirm the presence of lymph node and bone metastases. Two radiologists trained in nuclear medicine evaluated independently the uptake of lesions in F-18-FDG PET/CT and the signal-intensity of lesions in whole-body DWIBS visually. Interobserver difference was overcome through discussion to reach a consensus. The sensitivities, specificities, and overall accuracies of F-18-FDG PET/CT and whole-body DWIBS were compared using McNemer's test. Positive predictive values (PPVs) and negative predictive values (NPVs) of both modalities were compared using Fisher's exact test. The total numbers of lymph node regions and bone segments which were confirmed to have metastasis in the total 13 patients were 19 and 75, respectively. The sensitivity, specificity, overall accuracy, PPV, and NPV of F-18-FDG PET/CT for detecting lymph node metastasis from pediatric neuroblastoma were 100, 98.7, 98.9, 95.0, and 100%, respectively, and those for detecting bone metastasis were 90.7, 73.1, 80.3, 70.1, and 91.9%, respectively. In contrast, the sensitivity, specificity, overall accuracy, PPV, and NPV of whole-body DWIBS for detecting bone metastasis from pediatric neuroblastoma were 94.7, 24.0, 53.0, 46.4 and 86.7%, respectively, whereas those for detecting lymph node metastasis were 94.7, 85.3, 87.2, 62.1, and 98.5%, respectively. The low specificity, overall accuracy, and PPV of whole-body DWIBS for detecting bone metastasis were due to a high incidence of false-positive findings (82/108, 75.9%). The specificity, overall accuracy, and PPV of whole-body DWIBS for detecting lymph node metastasis were also significantly lower than those of F-18-FDG PET/CT for detecting lymph node metastasis, although the difference between these 2 modalities was less than that for detecting bone metastasis. The specificity, overall accuracy, and PPV of whole-body DWIBS are significantly lower than those of F-18-FDG PET/CT because of a high incidence of false-positive findings particularly for detecting bone metastasis, whereas whole-body DWIBS shows a similar level of sensitivities for detecting lymph node and bone metastases to those of F-18-FDG PET/CT. DWIBS should be carefully used for cancer staging in children because of its high incidence of false-positive findings in skeletons.
引用
收藏
页码:348 / 362
页数:15
相关论文
共 50 条
  • [1] Diagnostic performance of 18F-FDG PET/CT and whole-body diffusion-weighted imaging with background body suppression (DWIBS) in detection of lymph node and bone metastases from pediatric neuroblastoma
    Hiroaki Ishiguchi
    Shinji Ito
    Katsuhiko Kato
    Yusuke Sakurai
    Hisashi Kawai
    Naotoshi Fujita
    Shinji Abe
    Atsushi Narita
    Nobuhiro Nishio
    Hideki Muramatsu
    Yoshiyuki Takahashi
    Shinji Naganawa
    Annals of Nuclear Medicine, 2018, 32 : 348 - 362
  • [2] Detection of bone metastases through diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) compared with PET/CT 18F-NaF.
    Barragan-Campos, Hector Manuel
    Le Faou, Anne Laurence
    Burgos-Jaramillo, Martin
    Lopez-Soto, Fernando
    Ley, Javier Altamirano
    De la Pena-Lopez, Roberto
    JOURNAL OF CLINICAL ONCOLOGY, 2019, 37 (15)
  • [3] Supplemental value of diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) technique to whole-body magnetic resonance imaging in detection of bone metastases from thyroid cancer
    Sakurai, Yusuke
    Kawai, Hisashi
    Iwano, Shingo
    Ito, Shinji
    Ogawa, Hiroshi
    Naganawa, Shinji
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (03) : 297 - 305
  • [4] Diagnostic Value of Whole-Body DWI With Background Body Suppression Plus Calculation of Apparent Diffusion Coefficient at 3 T Versus 18F-FDG PET/CT for Detection of Bone Metastases
    Sun, Wenping
    Li, Mei
    Gu, Yifeng
    Sun, Zhenkui
    Qiu, Zhongling
    Zhou, Yiyi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (02) : 446 - 454
  • [5] Whole-body magnetic resonance/diffusion-weighted sequence with background signal suppression (WB-MR/DWIBS) vs. 18F-FDG PET/CT in diagnosis of lymphoma
    Gamal, Gihan Hassan
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01):
  • [6] Whole-body magnetic resonance/diffusion-weighted sequence with background signal suppression (WB-MR/DWIBS) vs. 18F-FDG PET/CT in diagnosis of lymphoma
    Gihan Hassan Gamal
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [7] DIFFUSION WEIGHTED WHOLE BODY IMAGING WITH BACKGROUND BODY SIGNAL SUPPRESSION (DWIBS) IN STAGING FOR NEUROBLASTOMA
    Ravikanth, B.
    PEDIATRIC BLOOD & CANCER, 2013, 60 : 120 - 120
  • [8] Whole-body MRI with diffusion weighted imaging with body suppression (DWIBS) in the follow up of paediatric Non-Hodgkin lymphoma: a comparison with 18F-FDG PET-CT
    Tondo, A.
    Olianti, C.
    Azzali, A.
    Cuzzubbo, D.
    Sanfilippo, C.
    Carra, F.
    Favre, C.
    De Filippi, C.
    Perrone, A. L.
    BRITISH JOURNAL OF HAEMATOLOGY, 2018, 182 : 40 - 40
  • [9] Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS): features and potential applications in oncology
    Thomas C. Kwee
    Taro Takahara
    Reiji Ochiai
    Rutger A. J. Nievelstein
    Peter R. Luijten
    European Radiology, 2008, 18 : 1937 - 1952
  • [10] Diffusion-weighted whole-body imaging with background body signal suppression (DWIBS): features and potential applications in oncology
    Kwee, Thomas C.
    Takahara, Taro
    Ochiai, Reiji
    Nievelstein, Rutger A. J.
    Luijten, Peter R.
    EUROPEAN RADIOLOGY, 2008, 18 (09) : 1937 - 1952