High-performance liquid chromatography with electrospray ionization ion mobility spectrometry: Characterization, data management, and applications

被引:10
|
作者
Zuehlke, Martin [1 ]
Riebe, Daniel [1 ]
Beitz, Toralf [1 ]
Loehmannsroeben, Hans-Gerd [1 ]
Andreotti, Sandro [2 ]
Reinert, Knut [2 ]
Zenichowski, Karl [3 ]
Diener, Marc [3 ]
机构
[1] Univ Potsdam, Phys Chem, Karl Liebknecht Str 24-25, D-14476 Potsdam, Germany
[2] Free Univ Berlin, Inst Comp Sci, Berlin, Germany
[3] KNAUER Wissensch Gerate GmbH, Berlin, Germany
关键词
Amino acids; Electrospray ionization; Ion mobility spectrometry; Pesticides; Two-dimensional separations; AMINO-ACID-ANALYSIS; MASS;
D O I
10.1002/jssc.201600749
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combination of high-performance liquid chromatography and electrospray ionization ion mobility spectrometry facilitates the two-dimensional separation of complex mixtures in the retention and drift time plane. The ion mobility spectrometer presented here was optimized for flow rates customarily used in high-performance liquid chromatography between 100 and 1500 mu L/min. The characterization of the system with respect to such parameters as the peak capacity of each time dimension and of the 2D spectrum was carried out based on a separation of a pesticide mixture containing 24 substances. While the total ion current chromatogram is coarsely resolved, exhibiting coelutions for a number of compounds, all substances can be separately detected in the 2D plane due to the orthogonality of the separations in retention and drift dimensions. Another major advantage of the ion mobility detector is the identification of substances based on their characteristic mobilities. Electrospray ionization allows the detection of substances lacking a chromophore. As an example, the separation of a mixture of 18 amino acids is presented. A software built upon the free mass spectrometry package OpenMS was developed for processing the extensive 2D data. The different processing steps are implemented as separate modules which can be arranged in a graphic workflow facilitating automated processing of data.
引用
收藏
页码:4756 / 4764
页数:9
相关论文
共 50 条
  • [1] Detection of carbohydrates by electrospray ionization ion mobility spectrometry following microbore high-performance liquid chromatography
    Lee, DS
    Wu, C
    Hill, HH
    JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (01) : 1 - 9
  • [2] An electrospray ionization-ion mobility spectrometer as detector for high-performance liquid chromatography
    Zuehlke, Martin
    Riebe, Daniel
    Beitz, Toralf
    Loehmannsroeben, Hans-Gerd
    Zenichowski, Karl
    Diener, Marc
    Linscheid, Michael W.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2015, 21 (03) : 391 - 402
  • [3] Determination of Seven Biogenic Amines in Tuna with High-Performance Liquid Chromatography Coupled to Electrospray Ionization Ion Mobility Spectrometry
    Xu, Yanfen
    Lu, Ying
    Yu, Jianna
    Liu, Wen
    Jing, Guoxing
    Li, Wenshan
    Liu, Wenjie
    FOOD ANALYTICAL METHODS, 2023, 16 (05) : 909 - 917
  • [4] Determination of Seven Biogenic Amines in Tuna with High-Performance Liquid Chromatography Coupled to Electrospray Ionization Ion Mobility Spectrometry
    Yanfen Xu
    Ying Lu
    Jianna Yu
    Wen Liu
    Guoxing Jing
    Wenshan Li
    Wenjie Liu
    Food Analytical Methods, 2023, 16 : 909 - 917
  • [5] Nano-electrospray ionization-ion mobility spectrometry and its combination with high performance liquid chromatography
    Chen Chuang
    Wang Weiguo
    Liang Xixi
    Zhou Qinghua
    Peng Liying
    Wen Meng
    Ju Bangyu
    Zhao Kun
    Liu Jun
    Li Haiyang
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (04) : 386 - 391
  • [6] Recent developments and applications of high-performance chromatography electrospray ionization mass spectrometry
    Dass, C
    CURRENT ORGANIC CHEMISTRY, 1999, 3 (02) : 193 - 209
  • [7] Determination of Artificial Sweeteners by High-Performance Ion-Mobility Spectrometry with Electrospray Ionization
    Sha, Min
    Zhang, Zhengyong
    Liu, Jun
    Wang, Haiyan
    ANALYTICAL LETTERS, 2017, 50 (06) : 936 - 944
  • [8] Determination of Tripamide in human urine by high-performance liquid chromatography and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Kim, Y
    Hwang, J
    Kim, M
    Lee, W
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (04) : 301 - 306
  • [9] Combination of High Performance Liquid Chromatography with Nano-electrospray ionization Chirp Z Transform Ion Mobility Spectrometry
    Shen Hong-Ling
    Meng Qing-Yan
    Jia Xu
    Liu Wen-Jie
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (06) : 809 - 816
  • [10] Characterization of polyunsaturated phospholipid remodeling in mammalian cells by high-performance liquid chromatography electrospray ionization mass spectrometry
    Kim, HY
    Wang, TCL
    Ma, YC
    BIOCHEMICAL AND BIOTECHNOLOGICAL APPLICATIONS OF ELECTROSPRAY IONIZATION MASS SPECTROMETRY, 1996, 619 : 267 - 280