A normothermic ex vivo organ perfusion delivery method for cardiac transplantation gene therapy

被引:44
|
作者
Bishawi, Muath [1 ,2 ]
Roan, Jun-Neng [1 ,3 ]
Milano, Carmelo A. [1 ]
Daneshmand, Mani A. [1 ]
Schroder, Jacob N. [1 ]
Chiang, Yuting [1 ]
Lee, Franklin H. [1 ]
Brown, Zachary D. [1 ]
Nevo, Adam [1 ]
Watson, Michael J. [1 ]
Rowell, Trevelyn [4 ]
Paul, Sally [4 ]
Lezberg, Paul [5 ]
Walczak, Richard [4 ]
Bowles, Dawn E. [6 ]
机构
[1] Duke Univ, Dept Surg, Div Cardiothorac Surg, Durham, NC USA
[2] Duke Univ, Dept Biomed Engn, Pratt Sch Engn, Durham, NC 27706 USA
[3] Natl Cheng Kung Univ Hosp, Div Cardiovasc Surg, Dept Surg, Coll Med, Tainan, Taiwan
[4] Duke Univ, Perfus Serv, Durham, NC USA
[5] TransMedics Inc, Andover, MA USA
[6] Duke Univ, Dept Surg, Div Surg Sci, Durham, NC 27708 USA
关键词
HEART-TRANSPLANTATION; CONTROLLED-TRIAL; EFFICIENT; DISEASE;
D O I
10.1038/s41598-019-43737-y
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Clinically, both percutaneous and surgical approaches to deliver viral vectors to the heart either have resulted in therapeutically inadequate levels of transgene expression or have raised safety concerns associated with extra-cardiac delivery. Recent developments in the field of normothermic ex vivo cardiac perfusion storage have now created opportunities to overcome these limitations and safety concerns of cardiac gene therapy. This study examined the feasibility of ex vivo perfusion as an approach to deliver a viral vector to a donor heart during storage and the resulting bio distribution and expression levels of the transgene in the recipient post-transplant. The influence of components (proprietary solution, donor blood, and ex vivo circuitry tubing and oxygenators) of the Organ Care System (OC) (TransMedics, Inc., Andover MA) on viral vector transduction was examined using a cell-based luciferase assay. Our ex vivo perfusion strategy, optimized for efficient Adenoviral vector transduction, was utilized to deliver 5 x 10(13) total viral particles of an Adenoviral firefly luciferase vector with a cytomegalovirus (CMV) promotor to porcine donor hearts prior to heterotopic implantation. We have evaluated the overall levels of expression, protein activity, as well as the bio distribution of the firefly luciferase protein in a series of three heart transplants at a five-day post-transplant endpoint. The perfusion solution and the ex vivo circuitry did not influence viral vector transduction, but the serum or plasma fractions of the donor blood significantly inhibited viral vector transduction. Thus, subsequent gene delivery experiments to the explanted porcine heart utilized an autologous blood recovery approach to remove undesired plasma or serum components of the donor blood prior to its placement into the circuit. Enzymatic assessment of luciferase activity in tissues (native heart, allograft, liver etc.) obtained post-transplant day five revealed wide-spread and robust luciferase activity in all regions of the allograft (right and left atria, right and left ventricles, coronary arteries) compared to the native recipient heart. Importantly, luciferase activity in recipient heart, liver, lung, spleen, or psoas muscle was within background levels. Similar to luciferase activity, the luciferase protein expression in the allograft appeared uniform and robust across all areas of the myocardium as well as in the coronary arteries. Importantly, despite high copy number of vector genomic DNA in transplanted heart tissue, there was no evidence of vector DNA in either the recipient's native heart or liver. Overall we demonstrate a simple protocol to achieve substantial, global gene delivery and expression isolated to the cardiac allograft. This introduces a novel method of viral vector delivery that opens the opportunity for biological modification of the allograft prior to implantation that may improve post-transplant outcomes.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A normothermic ex vivo organ perfusion delivery method for cardiac transplantation gene therapy
    Muath Bishawi
    Jun-Neng Roan
    Carmelo A. Milano
    Mani A Daneshmand
    Jacob N. Schroder
    Yuting Chiang
    Franklin H. Lee
    Zachary D. Brown
    Adam Nevo
    Michael J. Watson
    Trevelyn Rowell
    Sally Paul
    Paul Lezberg
    Richard Walczak
    Dawn E. Bowles
    Scientific Reports, 9
  • [2] Normothermic Ex Vivo Kidney Perfusion is a Safe Preservation Method for Kidney Transplantation
    Kaths, Moritz
    Echeverri, Juan
    Goldaracena, Nicolas
    Louis, Kristine
    Yip, Paul
    John, Rohan
    Mucsi, Istvan
    Ghanekar, Anand
    Bagli, Darius
    Lisa, Robinson
    Selzner, Markus
    AMERICAN JOURNAL OF TRANSPLANTATION, 2016, 16 : 40 - 40
  • [3] Ex vivo normothermic perfusion in heart transplantation: a review of the TransMedics(R) Organ Care System
    Pinnelas, Rebecca
    Kobashigawa, Jon A.
    FUTURE CARDIOLOGY, 2022, 18 (01) : 5 - 15
  • [4] Normothermic Ex Vivo Lung Perfusion in Clinical Lung Transplantation
    Yeung J.C.
    Keshavjee S.
    Current Transplantation Reports, 2015, 2 (4) : 324 - 328
  • [5] Normothermic Ex Vivo Lung Perfusion in Clinical Lung Transplantation
    Cypel, Marcelo
    Yeung, Jonathan C.
    Liu, Mingyao
    Anraku, Masaki
    Chen, Fengshi
    Karolak, Wojtek
    Sato, Masaaki
    Laratta, Jane
    Azad, Sassan
    Madonik, Mindy
    Chow, Chung-Wai
    Chaparro, Cecilia
    Hutcheon, Michael
    Singer, Lianne G.
    Slutsky, Arthur S.
    Yasufuku, Kazuhiro
    de Perrot, Marc
    Pierre, Andrew F.
    Waddell, Thomas K.
    Keshavjee, Shaf
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (15): : 1431 - 1440
  • [6] Liver Transplantation: Organ Preservation by normothermic Ex Situ Machine Perfusion
    Brudermanns, Britta
    TRANSFUSIONSMEDIZIN, 2022, 12 (04) : 209 - 209
  • [7] Normothermic Ex Situ Heart Perfusion With the Organ Care System for Cardiac Transplantation: A Meta-analysis
    Langmuur, Sanne J. J.
    Amesz, Jorik H.
    Veen, Kevin M.
    Bogers, Ad J. J. C.
    Manintveld, Olivier C.
    Taverne, Yannick J. H. J.
    TRANSPLANTATION, 2022, 106 (09) : 1745 - 1753
  • [8] First in Man Renal Transplantation After Ex Vivo Normothermic Perfusion
    Hosgood, Sarah A.
    Nicholson, Michael L.
    TRANSPLANTATION, 2011, 92 (07) : 735 - 738
  • [9] Ex-vivo Normothermic Perfusion in Marginal Donor Kidney Transplantation
    Hosgood, S.
    Barlow, A.
    Nicholson, M.
    BRITISH JOURNAL OF SURGERY, 2015, 102 : 104 - 105
  • [10] Normothermic and subnormothermic ex-vivo liver perfusion in liver transplantation
    Goldaracena, Nicolas
    Barbas, Andrew S.
    Selzner, Markus
    CURRENT OPINION IN ORGAN TRANSPLANTATION, 2016, 21 (03) : 315 - 321