CFD analysis on flow and performance parameters estimation of solar updraft tower (SUT) plant varying its geometrical configurations

被引:34
|
作者
Das, Pritam [1 ]
Chandramohan, V. P. [1 ]
机构
[1] Natl Inst Technol Warangal, Dept Mech Engn, Warangal 506004, Telangana, India
关键词
CFD simulations; collector roof angle; Solar updraft tower; turbulent flow; parametric study; CHIMNEY POWER-PLANT; COMPUTATIONAL FLUID-DYNAMICS; HEAT-TRANSFER; NUMERICAL-ANALYSIS; COLLECTOR ROOF; AIR-FLOW; ENERGY; OUTPUT;
D O I
10.1080/15567036.2018.1477881
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A 3D numerical model is developed to estimate and analyze the flow and performance parameters of solar updraft tower (SUT) plant. The effects of geometrical parameters, such as chimney height and collector roof angle are studied. A turbulent, renormalization group (RNG) k-epsilon model and discrete ordinates (DO) model is used to solve the governing equations. It is concluded that with an increase in collector roof angle, air velocity increases but air temperature decreases. There is 31% velocity enhancement when the chimney height is increased from 3 to 8 m. The overall, chimney and collector efficiencies and power output are estimated to be 0.00354%, 0.0465%, 81.4% and 0.255 W, respectively.
引用
收藏
页码:1532 / 1546