Development of void fraction-quality correlation for two-phase flow in horizontal and vertical tube bundles

被引:18
|
作者
Hibiki, Takashi [1 ]
Mao, Keyou [1 ]
Ozaki, Tetsuhiro [2 ]
机构
[1] Purdue Univ, Sch Nucl Engn, 400 Cent Dr, W Lafayette, IN 47907 USA
[2] Nucl Fuel Ind Ltd, Tokai Works, 3135-41 Muramatsu, Naka, Ibaraki 3191196, Japan
关键词
Void fraction; Cross flow; Horizontal bundle; Rod bundle; U tube; Steam generator;
D O I
10.1016/j.pnucene.2017.01.003
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A steam generator thermal-hydraulic code based on homogeneous flow model has been useful based on its numerical stability and simpler formulation. One of key parameters for a steam generator thermal hydraulic analysis is void fraction which determines two-phase mixture density and affects two-phase mixture velocity. These parameters are important for a heat transfer tube vibration analysis. A void fraction-quality correlation is very important to accurately convert the quality into the void fraction. The void fraction-quality correlation should preferably be applicable to parallel and cross flows in rod or tube bundles since two-phase flow in the steam generator encounters flow configuration change from the parallel flow along the tube bundle in the riser section of the steam generator to the cross flow in the U bend section of the steam generator. A set of correlations depending on flow configuration such as parallel and cross flows, rod or tube array pattern and mass flux is developed based on legacy Smith correlation. The correlation agrees with the parallel and cross flow data with the mean absolute error (or bias) of 0.117% and the standard deviation (random error) of 2.26% and with the mean absolute error (or bias) of 0.760% and the standard deviation (random error) of 6.21%, respectively. The correlations are further Simplified to a single correlation applicable for parallel and cross flow in rod or tube bundles. The Smith correlation with a modified constant entrainment parameter e being 0.5 is recommended for predicting void fraction in the steam generators. The Smith correlation with e = 0.5 is expected to be applicable for parallel and cross flows with various rod or tube array patterns including normal square, parallel triangular and normal triangular arrays. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:38 / 52
页数:15
相关论文
共 50 条
  • [1] An improved void fraction model for two-phase cross-flow in horizontal tube bundles
    Feenstra, PA
    Weaver, DS
    Judd, RL
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2000, 26 (11) : 1851 - 1873
  • [2] Void fraction and two-phase pressure drops for evaporating flow over horizontal tube bundles
    Consolini, L
    Robinson, D
    Thome, JR
    HEAT TRANSFER ENGINEERING, 2006, 27 (03) : 5 - 21
  • [3] Investigation of the void fraction-quality correlations for two-phase hydrogen flow based on the capacitive void fraction measurement
    Sakamoto, Yuki
    Kobayashi, Hiroaki
    Naruo, Yoshihiro
    Takesaki, Yuichiro
    Nakajima, Yo
    Furuichi, Atsuhiro
    Tsujimura, Hiroki
    Kabayama, Koki
    Sato, Tetsuya
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2019, 44 (33) : 18483 - 18495
  • [4] A porous media numerical prediction of void fraction and drift velocity in two-phase flow across horizontal tube bundles
    Stosic, ZV
    Stevanovic, VD
    CHT'01: ADVANCES IN COMPUTATIONAL HEAT TRANSFER II, VOLS 1 AND 2, PROCEEDINGS, 2001, : 961 - 968
  • [5] Void fraction distribution of vapor-water two-phase flow in vertical tube bundles using gamma densitometer
    Cheng J.
    Guo Y.
    Wang T.
    Gui M.
    Liu Z.
    Sui Z.
    Huagong Xuebao/CIESC Journal, 2019, 70 (04): : 1375 - 1382
  • [6] A New Capacitance Sensor for Measuring the Void Fraction of Two-Phase Flow Through Tube Bundles
    Ahmed, Wael
    Fatayerji, Adib
    Elsaftawy, Ahmed
    Hassan, Marwan
    Weaver, David
    Riznic, Jovica
    SENSORS, 2020, 20 (07)
  • [7] DETERMINATION OF TWO-PHASE FLOW VOID FRACTION OF R600A IN A HORIZONTAL SMOOTH TUBE
    Agra, Ozden
    Demir, Hakan
    Atayilmaz, S. Ozgar
    Yurtseven, Ahmet
    Dalkilic, A. Selim
    Wongwises, Somchai
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 7, PTS A-D, 2013, : 2547 - 2561
  • [8] Two-phase flow and heat transfer in horizontal tube bundles fitted with baffles of vertical cut
    Vazquez-Ramirez, E. E.
    Riesco-Avila, J. M.
    Polley, G. T.
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1274 - 1279
  • [9] Numerical analysis and correlation comparison of void fraction in refrigerant two-phase flow in horizontal tubes
    Liu, Chenxu
    Wang, Fang
    Gao, Yuping
    Zheng, Yongyu
    Li, Rixin
    APPLIED THERMAL ENGINEERING, 2025, 270
  • [10] The Measurement of Void Fraction of a Two-phase Flow in Vertical Riser Tubes
    Cai, Jiyong
    Chen, Tingkuan
    Ye, Qiang
    Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, 14 (01): : 30 - 33