Quality control during endovascular aneurysm repair: Monitoring aneurysmal sac pressure and superficial femoral artery flow velocity

被引:0
|
作者
Treharne, GD [1 ]
Loftus, IM [1 ]
Thompson, MM [1 ]
Lennard, N [1 ]
Smith, J [1 ]
Fishwick, G [1 ]
Bell, PRF [1 ]
机构
[1] Univ Leicester, Leicester Royal Infirm, Dept Surg, Leicester LE2 7LX, Leics, England
来源
JOURNAL OF ENDOVASCULAR SURGERY | 1999年 / 6卷 / 03期
关键词
Doppler ultrasound; endografts; endovascular grafting; endoleak;
D O I
10.1583/1074-6218(1999)006<0239:QCDEAR>2.0.CO;2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: To use intraoperative aneurysmal sac pressure measurement and flow monitoring of the superficial femoral artery (SFA) to ensure complete exclusion of the aneurysm from the circulation. Methods: A 5F catheter was positioned in the aneurysmal sac of 15 consecutive patients undergoing endovascular aortomonoiliac aneurysm repair between February and September 1997. The catheter was connected to an external pressure transducer allowing pressure monitoring throughout the operation and for 24 hours postprocedurally. Flow velocity was monitored in the contralateral SFA by insonation with a 2-MHz Doppler ultrasound probe. Results: No technical defect was observed in the deployment of 10 endografts, which demonstrated marked reduction in sac pressure and good flow in the lower limb. The mean aneurysm pressure dropped from 123 to 57 mmHg after graft insertion. In 5 cases, monitoring detected problems during the endograft procedure. In 3, incomplete stent deployment was detected by a failure of sac pressure to fall following stent inflation and by the presence of flow in the contra lateral femoral artery. In the other 2 cases, a distal endoleak was detected by direct injection of contrast into the sac. Conclusions: Measuring aneurysm pressure in combination with SFA Doppler flow monitoring can detect complications of endovascular aneurysm repair.
引用
收藏
页码:239 / 245
页数:7
相关论文
共 30 条
  • [1] The Superficial Femoral Artery: An Alternative Access for Percutaneous Endovascular Aneurysm Repair
    Aaron, Ashley
    el-Hag, Selma
    de Grandis, Eileen
    Santilli, Steve
    Rosenberg, Michael
    Shafii, Susan M.
    Golzarian, Jafar
    Faizer, Rumi
    ANNALS OF VASCULAR SURGERY, 2017, 38 : 339 - 344
  • [2] Superficial Femoral Artery Use for Percutaneous Endovascular Aortic Aneurysm Repair
    Faizer, Rumi
    Aaron, Ashley
    Trieu, Huy
    Levin, Steve
    Messelt, Andrew
    Rosenberg, Michael
    Santilli, Steve
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (04) : 1099 - 1100
  • [3] Quality control during endovascular aneurysm repair
    Loftus, IM
    Thompson, MM
    Lennard, N
    Steele, S
    Smith, J
    Treharne, G
    Fishwick, G
    Bell, PRF
    BRITISH JOURNAL OF SURGERY, 1998, 85 (04) : 568 - 568
  • [4] Superficial Femoral Artery Exposure Compared With Common Femoral and Percutaneous Approaches for Endovascular Aortic Aneurysm Repair
    Aaron, Ashley E.
    Faizer, Rumi
    Mockenhaupt, Elizabeth
    Santilli, Steven M.
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (03) : 828 - 829
  • [5] Measurement of Intra-Aneurysm Sac Pressure During Endovascular Abdominal Aneurysm Repair
    Maruyama, Ryushi
    Yamada, Akira
    Nojima, Masanori
    Kurimoto, Yoshihiko
    Nakanishi, Katsuhiko
    JOURNAL OF VASCULAR SURGERY, 2017, 65 (06) : 67S - 67S
  • [6] Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair
    Ishibashi, Hiroyuki
    Ishiguchi, Tsuneo
    Ohta, Takashi
    Sugimoto, Ikuo
    Iwata, Hirohide
    Yamada, Tetsuya
    Tadakoshi, Masao
    Hida, Noriyuki
    Orimoto, Yuki
    Kamei, Seiji
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (05) : 939 - 942
  • [7] Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair
    Hiroyuki Ishibashi
    Tsuneo Ishiguchi
    Takashi Ohta
    Ikuo Sugimoto
    Hirohide Iwata
    Tetsuya Yamada
    Masao Tadakoshi
    Noriyuki Hida
    Yuki Orimoto
    Seiji Kamei
    CardioVascular and Interventional Radiology, 2010, 33 : 939 - 942
  • [8] Aneurysm Sac Pressure during Branched Endovascular Aneurysm Repair versus Multilayer Flow Modulator Implantation in Patients with Thoracoabdominal Aortic Aneurysm
    Antkiewicz, Maciej
    Kuliczkowski, Wiktor
    Protasiewicz, Marcin
    Zubilewicz, Tomasz
    Terlecki, Piotr
    Kobielarz, Magdalena
    Janczak, Dariusz
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (21)
  • [9] Intra-aneurysm sac pressure measurement using a thin pressure wire during endovascular aneurysm repair
    Antkiewicz, Maciej
    Kuliczkowski, Wiktor
    Protasiewicz, Marcin
    Kobielarz, Magdalena
    Barc, Piotr
    Malinowski, Maciej
    Fraczkowska, Katarzyna
    Kulikowska, Katarzyna
    Merenda, Marcin
    Jacyna, Krzysztof
    Dawiskiba, Tomasz
    Janczak, Dariusz
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2021, 30 (03): : 309 - 313
  • [10] Inguinal Field Block for Femoral Artery Exposure During Endovascular Aneurysm Repair
    Setacci, Francesco
    Sirignano, Pasqualino
    Kamargianni, Vasiliki
    Galzerano, Giuseppe
    de Donato, Gianmarco
    Biandolino, Pasquale
    Cappelli, Alessandro
    Setacci, Carlo
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (05) : 655 - 662