An evaluation of image noise variance for time-of-flight PET

被引:0
|
作者
Watson, Charles C. [1 ]
机构
[1] Siemens Med Solut Mol Imaging, Knoxville, TN 37932 USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe a simple theoretical framework for linear time-of-flight (TOF) reconstruction and evaluate several alternative TOF filters. We implement a capability for direct computation of TOF noise variance images and evaluate the gain in image variance for TOF vs. non-TOF for 1.26 nsec TOF resolution on the Siemens biograph HiRez PET/CT. The variance calculation is validated by comparing to pixel variances computed from replicated synthetic data. TOF reconstruction does not give a uniform improvement in image noise variance, but improves variance more toward the periphery of an object than at its center. The TOF performance gain depends on how random coincidences are processed, and is greater when the randoms fraction is higher, or when randoms smoothing is not employed. We confirm that TOF gain is greater for larger objects than for smaller ones, but find discrepancies with the D/Delta x rule of thumb. With 1.26 nsec resolution on the HiRez, TOF image noise gain factors (non-TOF/TOF variance) range from 1.5 to 2.2 on the measured data at hand. We predict that an improvement in TOF resolution by a factor of 2 (to 600 psec) could improve image variance on this machine by an additional factor of 1.8. We find that confidence weighted TOF reconstruction under-performs non-TOF reconstruction for objects whose diameters are small compared to the TOF resolution.
引用
收藏
页码:2041 / 2045
页数:5
相关论文
共 50 条
  • [1] An evaluation of image noise variance for time-of-flight PET
    Watson, Charles C.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (05) : 1639 - 1647
  • [2] Evaluation of Image Signal-to-Noise Ratio in Time-of-flight PET
    Clementel, Enrico
    Vandenberghe, Stefaan
    Karp, Joel S.
    Surti, Suleman
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3917 - 3921
  • [3] Fast Estimation of Image Variance for Time-of-flight PET Reconstruction
    Wang, Mengdie
    Hu, Guangshu
    El Fakhri, Georges
    Zhang, Hui
    Li, Quanzheng
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [4] Image Noise Variance in 3D OSEM Reconstruction of Clinical Time-of-Flight PET
    Watson, Charles C.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1736 - 1739
  • [5] Evaluation of Windowed Image Reconstruction for Time-Of-Flight PET
    Guo, Jinxia
    Kao, Chien-Min
    Xie, Qinguo
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4162 - 4166
  • [6] Image quality evaluation on a new time-of-flight PET
    Turkington, Timothy
    Williams, John
    Wollenweber, Scott
    Stearns, Charles
    Ganin, Alexander
    Wilson, Joshua
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [7] Evaluation of Image Quality on a Time-Of-Flight PET/CT Scanner
    Chang, T.
    Clark, J.
    Mawlawi, O.
    MEDICAL PHYSICS, 2011, 38 (06) : 3787 - +
  • [8] Comparison of Image Signal-to-noise Ratio and Noise Equivalent Counts in Time-of-flight PET
    Clementel, Enrico
    Vandenberghe, Stefaan
    Karp, Joel S.
    Surti, Suleman
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3622 - 3625
  • [9] Time-of-flight precision and PET image accuracy
    Kolthammer, Jeffrey A.
    Tang, Jing
    Perkins, Amy E.
    Muzic, Raymond F., Jr.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3657 - 3660
  • [10] Evaluation of Fourier rebinning of time-of-flight PET data to non time-of-flight
    Li, Quanzheng
    Cho, S.
    Ahn, S.
    Ren, R.
    Leahy, R.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50