Window Settings for the Study of Calcified Carotid Plaques with Multidetector CT Angiography

被引:44
|
作者
Saba, L. [1 ]
Mallarini, G. [2 ]
机构
[1] Policlin Univ, Dept Sci Images, I-09045 Cagliari, Italy
[2] Univ Cagliari, Inst Radiol, Cagliari, Italy
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; SPIRAL CT; ATHEROSCLEROTIC PLAQUE; ARTERY STENOSIS; ISCHEMIC SYMPTOMS; DISEASE; BIFURCATION; APPEARANCE; COMPONENTS; ACCURACY;
D O I
10.3174/ajnr.A1509
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
CT angiography (CTA) shows high sensitivity in detecting calcified plaques, but sometimes a bias in the exact quantification of stenosis degree occurs, mainly caused by the high linear attenuation coefficient of the calcified plaques. The purpose of this technical study was to evaluate the most appropriate CT window parameters for the assessment of calcified plaques stating which of them can provide the best inter-observer agreement. Scatter-plots and regression results showed the correlation between both width and level respectively depending on intraluminal Hounsfield units (HU) value (width = intraluminal HU x 2.07; level = intraluminal HU x 0.72). Obtained data indicated that the presence of different stenosis degrees did not modify visualization parameters.
引用
收藏
页码:1445 / 1450
页数:6
相关论文
共 50 条
  • [1] Evolution of Atherosclerotic Carotid Plaque Morphology: Do Ulcerated Plaques Heal? A Serial Multidetector CT Angiography Study
    van Gils, M. J.
    Homburg, P. J.
    Rozie, S.
    de Weert, T. T.
    Dippel, D. W. J.
    van der Lugt, A.
    CEREBROVASCULAR DISEASES, 2011, 31 (03) : 263 - 270
  • [2] Multidetector-row CT angiography in the study of atherosclerotic carotid arteries
    Saba, Luca
    Sanfilippo, Roberto
    Pirisi, Raimondo
    Pascalis, Luigi
    Montisci, Roberto
    Mallarini, Giorgio
    NEURORADIOLOGY, 2007, 49 (08) : 623 - 637
  • [3] Multidetector-row CT angiography in the study of atherosclerotic carotid arteries
    Luca Saba
    Roberto Sanfilippo
    Raimondo Pirisi
    Luigi Pascalis
    Roberto Montisci
    Giorgio Mallarini
    Neuroradiology, 2007, 49 : 623 - 637
  • [4] Computerized assessment of motion-contaminated calcified plaques in cardiac multidetector CT
    King, Martin
    Giger, Maryellen L.
    Suzuki, Kenji
    Bardo, Dianna M. E.
    Greenberg, Brent
    Lan, Li
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2007, 34 (12) : 4876 - 4889
  • [5] Accuracy of multidetector CT in assessing the degree of stenosis caused by calcified coronary artery plaques
    Zhang, Shaoxiong
    Levin, David
    Halpern, Ethan
    Fischman, David
    Savage, Michael
    Walinsky, Paul
    CIRCULATION, 2007, 116 (16) : 691 - 692
  • [6] Noninvasive detection of calcified and non-calcified coronary plaques by Multidetector-row CT: A comparison with intracoronary ultrasound
    Kopp, AF
    Schroeder, S
    Kuettner, A
    Ohnesorge, BM
    Georg, C
    Claussen, CD
    RADIOLOGY, 2000, 217 : 234 - 234
  • [7] Is It Possible That This Patient is Asymptomatic? The Role of Multidetector CT Angiography in Detection of Ulcerated Plaques in Patients with Asymptomatic Carotid Stenosis: Case Report
    Tanaskovic, Slobodan
    Babic, Srdjan
    Aleksic, Nikola
    Matic, Predrag
    Gajin, Predrag
    Jocic, Dario
    Radak, Djordje
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2015, 143 (9-10) : 615 - 618
  • [8] Improving Visualization of Intracranial Arteries at the Skull Base for CT Angiography with Calcified Plaques
    Huang, Adam
    Lee, Chung-Wei
    Yang, Chung-Yi
    Liu, Hon-Man
    MEDICAL IMAGING 2010: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2010, 7626
  • [9] Multidetector CT angiography in the diagnosis and classification of carotid-cavernous fistula
    Lee, J. Y.
    Jung, C.
    Ihn, Y. K.
    Kim, D. J.
    Seong, S. O.
    Kwon, B. J.
    CLINICAL RADIOLOGY, 2016, 71 (01) : E64 - E71
  • [10] Feature-based characterization of motion-contaminated calcified plaques in cardiac multidetector CT
    King, Martin
    Giger, Maryellen L.
    Suzuki, Kenji
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2007, 34 (12) : 4860 - 4875