Optimization of conditions in on-line comprehensive two-dimensional reversed phase liquid chromatography. Experimental comparison with one-dimensional reversed phase liquid chromatography for the separation of peptides

被引:56
|
作者
Sarrut, Morgan [1 ]
D'Attoma, Amelie [1 ]
Heinisch, Sabine [1 ]
机构
[1] Univ Lyon, Inst Sci Analyt, UMR CNRS UCBL ENS 5280, F-69100 Villeurbanne, France
关键词
Comprehensive two-dimensional liquid chromatography; 2D-LC; RPLC x RPLC; Peptides; Protein digest; LC x LC optimization; PEAK-CAPACITY OPTIMIZATION; GRADIENT ELUTION; KINETIC PERFORMANCE; PARETO-OPTIMALITY; COLUMN; TEMPERATURE; MIXTURES; RESOLUTION; EFFICIENCY; PRESSURE;
D O I
10.1016/j.chroma.2015.08.052
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive on-line two-dimensional liquid chromatography is an attractive technique to enhance peak capacity and deal with complex samples. Yet, its optimization is not straightforward and requires to take into account a huge number of parameters to finally obtain a good compromise between different criteria which are often conflicting. In this study, we propose a procedure for RPLC x RPLC separations able to define, for a given analysis time, the optimized LC x LC parameters for achieving the best compromise between high peak capacity and low dilution. This procedure makes use of both a prediction tool based on theoretical relationships and a Pareto-optimality approach to optimize these two criteria. The possibility to split the flow-rate of the first dimension before the interface is taken into account as well as the focusing effect in the second dimension. This optimization procedure is applied to the prediction of optimized conditions for the separation of peptides. The need for very short and efficient columns (typically 30 mm as column length and 1.3 mu m as particle diameter) in the second dimension is clearly established whatever the geometry of the first dimension column. Furthermore it is shown that several sets of quite different conditions in the first dimension can lead to similar results and hence that additional quality descriptors are required to make a decision. RPLC x RPLC separations of a protein digest were carried out and the obtained results were found in very good accordance with the predicted ones. Our results were compared to the top results reported lathe literature for 1D-RPLC separations of peptides. More than 4-fold increase in peak capacity (5100 vs 1150) at 200 min has been obtained. Furthermore a 40-fold gain in analysis time (1 h vs 40h) was obtained for achieving 1800 as effective peak capacity which is close to the highest peak capacity reported in 1D-RPLC for the separation of peptides. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 59
页数:12
相关论文
共 50 条
  • [1] Pulsed elution modulation for on-line comprehensive two-dimensional liquid chromatography coupling reversed phase liquid chromatography and hydrophilic interaction chromatography
    Chen, Yingzhuang
    Wu, Yajun
    Liu, Xiaoming
    Li, Bowen
    Hu, Deping
    Huang, Si
    Ma, Ming
    Chen, Bo
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1583 : 98 - 107
  • [2] Optimization of comprehensive two-dimensional gradient chromatography coupling in-line hydrophilic interaction and reversed phase liquid chromatography
    Jandera, Pavel
    Hajek, Tomas
    Stankova, Magda
    Vynuchalova, Katerina
    Cesla, Petr
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1268 : 91 - 101
  • [3] On-line comprehensive two-dimensional normal-phase liquid chromatography x reversed-phase liquid chromatography for preparative isolation of toad venom
    Li, Jia-Fu
    Fang, Hua
    Yan, Xia
    Chang, Fang-Rong
    Wu, Zhen
    Wu, Yun-Long
    Qiu, Ying-Kun
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1456 : 169 - 175
  • [4] On-line comprehensive two-dimensional normal-phase liquid chromatography x reversed-phase liquid chromatography for preparative isolation of Peucedanum praeruptorum
    Wang, Xin-Yuan
    Li, Jia-Fu
    Jian, Ya-Mei
    Wu, Zhen
    Fang, Mei-Juan
    Qiu, Ying-Kun
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1387 : 60 - 68
  • [5] Optimization of a comprehensive two-dimensional normal-phase and reversed-phase liquid chromatography system
    Dugo, Paola
    Fernandez, Maria del Mar Ramirez
    Cotroneo, Antonella
    Dugo, Giovanni
    Mondello, Luigi
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2006, 44 (09) : 561 - 565
  • [6] Impact of reversed phase column pairs in comprehensive two-dimensional liquid chromatography
    Allen, Robert C.
    Barnes, Brian B.
    Ahmad, Imad A. Haidar
    Filgueira, Marcelo R.
    Carr, Peter W.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1361 : 169 - 177
  • [7] On-line comprehensive two dimensional separations of charged compounds using reversed-phase high performance liquid chromatography and hydrophilic interaction chromatography. Part II: Application to the separation of peptides
    D'Attoma, Amelie
    Heinisch, Sabine
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1306 : 27 - 36
  • [8] Comprehensive two-dimensional normal-phase (adsorption) - Reversed-phase liquid chromatography
    Dugo, P
    Favoino, O
    Luppino, R
    Dugo, G
    Mondello, L
    ANALYTICAL CHEMISTRY, 2004, 76 (09) : 2525 - 2530
  • [9] Comprehensive two-dimensional separations of complex mixtures using reversed-phase reversed-phase liquid chromatography
    Gray, MJ
    Dennis, GR
    Slonecker, PJ
    Shalliker, RA
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1041 (1-2) : 101 - 110
  • [10] Comprehensive two-dimensional chromatography with coupling of reversed phase high performance liquid chromatography and supercritical fluid chromatography
    Stevenson, Paul G.
    Tarafder, Abhijit
    Guiochon, Georges
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1220 : 175 - 178