Feasibility study on computer-aided screening for diabetic retinopathy

被引:20
|
作者
Singalavanija, Apichart
Supokavej, Jirayuth
Bamroongsuk, Parapan
Sinthanayothin, Chanjira
Phoojaruenchanachai, Suthee
Kongbunkiat, Viravud
机构
[1] Siriraj Hosp, Dept Ophthalmol, Fac Med, Bangkok 10700, Thailand
[2] Natl Elect & Comp Technol Ctr, Bangkok, Thailand
关键词
diabetic retinopathy; digital image; screening;
D O I
10.1007/s10384-005-0328-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To conduct a feasibility study of computer-aided screening for diabetic retinopathy by developing a computerized program to automatically detect retinal changes from digital retinal images. Methods: The study was carried out in three steps. Step 1 was to collect baseline retinal image data of 600 eyes of normal subjects with normal fundi and data of 300 eyes of diabetic patients with diabetic retinopathy. All data were recorded by digital fundus camera. Step 2 was to analyse all retinal images for normal and abnormal features. By this method, the automated computerized screening program was developed. The program preprocesses colour retinal images and recognizes the main retinal components (optic disc, fovea, and blood vessels) and diabetic features such as exudates, haemorrhages, and microaneurysms. All of the accumulated information is interpreted as normal, abnormal, or unknown. Step 3 was to evaluate the sensitivity and specificity of the computerized screening program by testing the program on diabetic patients and comparing the program's results with the results of screening by retinal specialists. Results: Diabetic patients (182 patients, 336 eyes) were examined by retinal specialists; 221 eyes had a normal fundus and 115 eyes had nonproliferative diabetic retinopathy. Digital retinal images were taken of these 336 eyes and interpreted by the automated screening program. The program had a sensitivity and specificity of 74.8% and 82.7%, respectively. Conclusions: The automated screening program was able to differentiate between the normal fundus and the diabetic retinopathy fundus. The program may be beneficial for use in screening for diabetic retinopathy. Further development of the program may provide higher sensitivity.
引用
收藏
页码:361 / 366
页数:6
相关论文
共 50 条
  • [1] Feasibility Study on Computer-Aided Screening for Diabetic Retinopathy
    Apichart Singalavanija
    Jirayuth Supokavej
    Parapan Bamroongsuk
    Chanjira Sinthanayothin
    Suthee Phoojaruenchanachai
    Viravud Kongbunkiat
    [J]. Japanese Journal of Ophthalmology, 2006, 50 : 361 - 366
  • [2] The Appropriateness of Digital Diabetic Retinopathy Screening Images for a Computer-Aided Glaucoma Screening System
    Almazroa, Ahmed A.
    Woodward, Maria A.
    Newman-Casey, Paula Anne
    Shah, Manjool M.
    Elam, Angela R.
    Kamat, Shivani S.
    Karvonen-Gutierrez, Carrie A.
    Wood, Sarah D.
    Kumar, Navasuja
    Moroi, Sayoko E.
    [J]. CLINICAL OPHTHALMOLOGY, 2020, 14 : 3881 - 3890
  • [3] Computer-aided diagnosis of diabetic retinopathy: A review
    Mookiah, Muthu Rama Krishnan
    Acharya, U. Rajendra
    Chua, Chua Kuang
    Lim, Choo Min
    Ng, E. Y. K.
    Laude, Augustinus
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (12) : 2136 - 2155
  • [4] Computer-aided Diagnosis of Proliferative Diabetic Retinopathy
    Oloumi, Faraz
    Rangayyan, Rangaraj M.
    Ells, Anna L.
    [J]. 2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1438 - 1441
  • [5] Evaluation of a Computer-Aided Diagnosis System for Diabetic Retinopathy Screening on Public Data
    Sanchez, Clara I.
    Niemeijer, Meindert
    Dumitrescu, Alina V.
    Suttorp-Schulten, Maria S. A.
    Abramoff, Michael D.
    van Ginneken, Bram
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) : 4866 - 4871
  • [6] Quantitative OCT angiography for computer-aided classification of diabetic retinopathy
    Alam, Minhaj Nur
    Zhang, Yue
    Lim, Jennifer I.
    Chan, Robison Vernon Paul
    Yang, Min
    Yao, Xincheng
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [7] Computer-aided diagnosis for Diabetic Retinopathy based on Firefly algorithm
    Keerthiveena, B.
    Veerakumar, T.
    Esakkirajan, S.
    Subudhi, Badri Narayan
    [J]. 2019 11TH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTING (ICOAC 2019), 2019, : 310 - 315
  • [8] Untangling Computer-Aided Diagnostic System for Screening Diabetic Retinopathy Based on Deep Learning Techniques
    Farooq, Muhammad Shoaib
    Arooj, Ansif
    Alroobaea, Roobaea
    Baqasah, Abdullah M.
    Jabarulla, Mohamed Yaseen
    Singh, Dilbag
    Sardar, Ruhama
    [J]. SENSORS, 2022, 22 (05)
  • [9] A FEASIBILITY STUDY OF COMPUTER-AIDED DIAGNOSIS IN APPENDICITIS
    VANWAY, CW
    MURPHY, JR
    DUNN, EL
    ELERDING, SC
    [J]. SURGERY GYNECOLOGY & OBSTETRICS, 1982, 155 (05): : 685 - 688
  • [10] Computer-aided screening
    不详
    [J]. EUROPEAN JOURNAL OF CANCER, 2003, 39 (16) : 2250 - 2250