摘要
The depth, thickness and expanse of sandstones or sandy material in site candidate of the disposal demo in Serpong nuclear area (SNA) need to be identified. This is considered because sandstones as ground water aquifers will potentially serve as a medium for transporting radionuclides from waste to biosphere. For design optimization and safety assessment of radioactive waste disposal facility so as not to endanger the public and environment, it is necessary to identify the sandstone layer data. This study was conducted with primary data at SNA using the Wenner configuration of resistivity geoelectricity method on five lines. Data processing and modeling is done through RES2DINV software to obtain the resistivity value of rocks that represent sandstone beneath the surface. In the line 1, the sandstone is at a depth of 6 m and 10 m with a resistivity value of 2,13 -9,40 Om. In the line 2, the sandstone is at a depth of 12,5 m and 17,5 m with a resistivity value of 0,51 - 1,43 Om. In the line 3, the sandstone is at a depth of 18 m with a resistivity value of 0,70 - 3,28 Om. In the line 4, the sandstone is at a depth of 30 m with a resistivity value of 3,97 - 8,48 Om and in the line 5, sandstone is at a depth of 16 m with a resistivity value of 1,12 Om. Based on the results of the assessment, all the lines meet the safety requirements of radioactive waste disposal because there is a sufficient barrier zone between the base of the repository and the sandstone as groundwater aquifer, line 1 has a thickness of 4 m and 8 m, line 2 has a thickness of 10,5 m and 15,5 m, line 3 has a thickness of 16 m, line 4 has a thickness of 28 m and line 5 has a thickness of 14 m.
引用
收藏
页数:10
相关论文
共 5 条
  • [1] Groundwater potential zones delineation using geo-electrical resistivity method and GIS for Coimbatore, India
    Shantharam, Y.
    Elangovan, K.
    INDIAN JOURNAL OF GEO-MARINE SCIENCES, 2018, 47 (05) : 1088 - 1095
  • [2] Delineation of leachate at a dumpsite using geo-electrical resistivity method: a case study of Abule Egba, Lagos, Nigeria
    Okunowo, Oluwafemi Olutayo
    Adeogun, Oluwakemi Yemisi
    Ishola, Kehinde Saheed
    Alli, Saheed
    SN APPLIED SCIENCES, 2020, 2 (12):
  • [3] Delineation of leachate at a dumpsite using geo-electrical resistivity method: a case study of Abule Egba, Lagos, Nigeria
    Oluwafemi Olutayo Okunowo
    Oluwakemi Yemisi Adeogun
    Kehinde Saheed Ishola
    Saheed Alli
    SN Applied Sciences, 2020, 2
  • [4] Coal Layer Identification using Electrical Resistivity Imaging Method in Sinjai Area South Sulawesi
    Samanlangi, Andi Ilham
    2ND INTERNATIONAL CONFERENCE ON SCIENCE (ICOS), 2018, 979
  • [5] Stratigraphy Identification with Emphasis to Shells Layer using 2-D Electrical Resistivity Method at Guar Kepah, Penang
    Rosli, Najmiah
    Mansor, Hafizuddin
    Ismail, N. A.
    Masnan, S. S. K.
    Saidin, M.
    INTERNATIONAL SEMINAR ON MATHEMATICS AND PHYSICS IN SCIENCES AND TECHNOLOGY 2017 (ISMAP 2017), 2018, 995