High Frame Rate Synthetic Aperture Duplex Imaging

被引:1
|
作者
Stuart, Matthias Bo [1 ]
Tomov, Borislav Gueorguiev [1 ]
Pihl, Michael Johannes [1 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, Lyngby, Denmark
关键词
D O I
10.1109/ULTSYM.2013.0161
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Conventional color flow images are limited in velocity range and can either show the high velocities in systole or be optimized for the lower diastolic velocities. The full dynamics of the flow is, thus, hard to visualize. The dynamic range can be significantly increased by employing synthetic aperture flow imaging as demonstrated in this paper. Synthetic aperture, directional beamforming, and cross-correlation are used to produce B-mode and vector velocity images at high frame rates. The frame rate equals the effective pulse repetition frequency of each imaging mode. Emissions for making the B-mode images and velocity maps are interleaved in a 1-to-1 ratio. This provides continuous data allowing a wide range of velocities to be estimated. Two cases are considered in the flow estimation: In the first case, the angle of the flow is determined from the B-mode image. In the other case, the angle is determined by estimating the flow velocity in all directions and choosing the one with the strongest correlation. The method works for all angles, including fully axial and fully transverse flows. Field II simulations with a 192 element, 7 MHz linear array are made of laminar, transverse flow profiles. For a simulated peak velocity of 0.5 m/s, the relative bias is -6.8% and the relative standard deviation is 6.1%. The bias on the angle is 0.98 degrees with a standard deviation of 2.39 degrees when using the flow estimator to determine the angle. For a peak velocity of 0.05 m/s, the relative bias of the velocity estimation is -1.8% and the relative standard deviation 5.4%. The approach can thus estimate both high and low velocities with equal accuracy and thereby makes it possible to present vector flow images with a high dynamic range. Measurements are made using the SARUS research scanner, a linear array transducer similar to the simulated one, and a recirculating flow rig with a blood mimicking fluid and a parabolic flow profile with a peak velocity of approximately 0.3 m/s. The relative bias of the velocity estimation is 0.19% and the mean relative standard deviation 4.9%. For the direction estimation, the bias is 3.2 degrees with a standard deviation of 1.6 degrees.
引用
收藏
页码:619 / 622
页数:4
相关论文
共 50 条
  • [1] High frame rate and high resolution imaging with synthetic aperture
    Kim, KS
    Song, TK
    [J]. ADVANCES IN NONDESTRUCTIVE EVALUATION, PT 1-3, 2004, 270-273 : 168 - 173
  • [2] High frame rate and high resolution imaging with synthetic aperture
    Ctr. for Medical Solutions Research, Department of Electronic Engineering, Sogang University, C.P.O. Box 1142, Seoul, Korea, Republic of
    [J]. 1600, 168-173 (2004):
  • [3] ApodNet: Learning for High Frame Rate Synthetic Transmit Aperture Ultrasound Imaging
    Chen, Yinran
    Liu, Jing
    Luo, Xiongbiao
    Luo, Jianwen
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (11) : 3190 - 3204
  • [4] High frame rate synthetic aperture vector flow imaging for transthoracic echocardiography
    Villagomez-Hoyos, Carlos A.
    Stuart, Matthias B.
    Bechsgaard, Thor
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    [J]. MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [5] Coded excitation waveform engineering for high frame rate synthetic aperture ultrasound imaging
    Lashkari, Bahman
    Zhang, Kaicheng
    Dovlo, Edem
    Mandelis, Andreas
    [J]. ULTRASONICS, 2017, 77 : 121 - 132
  • [6] In-Vivo Synthetic Aperture and Plane Wave High Frame Rate Cardiac Imaging
    Stuart, Matthias Bo
    Jensen, Jonas
    Brandt, Andreas Hjelm
    Nikolov, Svetoslav Ivanov
    Nielsen, Michael Bachmann
    Jensen, JOrgen Arendt
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 1209 - 1212
  • [7] High Frame Rate Super Resolution Imaging Based on Ultrasound Synthetic Aperture Scheme
    Wada, Takayuki
    Ho, Yihsin
    Okubo, Kan
    Tagawa, Norio
    Hirose, Yoshiyasu
    [J]. PROCEEDINGS OF THE 2015 ICU INTERNATIONAL CONGRESS ON ULTRASONICS, 2015, 70 : 1216 - 1220
  • [8] High Frame Rate Synthetic Aperture 3D Vector Flow Imaging
    Villagomez-Hoyos, Carlos A.
    Holbek, Simon
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [9] DeNet: Optimizing of transmit delays for high frame rate synthetic transmit aperture imaging
    Lan, Xinze
    Zhang, Jingke
    Luo, Jianwen
    [J]. 2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [10] A Data-Driven Approach for High Frame Rate Synthetic Transmit Aperture Ultrasound Imaging
    Chen, Yinran
    Liu, Jing
    Luo, Jianwen
    Luo, Xiongbiao
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT VI, 2021, 12906 : 412 - 420