Establishment of internal quality control system in anti-mitochondrial antibody subtype M2 detection by using human serum as quality control material

被引:0
|
作者
Zhu, Zhong-Liang [1 ]
Xu, Juan [2 ]
Zhou, Yong-Lie [1 ]
He, Fang [1 ]
机构
[1] Hangzhou Med Coll, Peoples Hosp, Zhejiang Prov Peoples Hosp, Dept Clin Lab, 158 Shangtang Rd, Hangzhou 310014, Zhejiang, Peoples R China
[2] Zhejiang Acad Med Sci, Inst Hyg, Hangzhou 310013, Zhejiang, Peoples R China
关键词
Internal quality control; AMA-M2; pooled serum; primary biliary cirrhosis; PRIMARY BILIARY-CIRRHOSIS; STABILITY; ASSAYS;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Internal quality control (QC) material is important for day-to-day checking of analytical processes in a clinical laboratory. For anti-mitochondrial antibody subtype M2 (AMA-M2) detection, there are no commercial QC materials available. In this study, pooled serum was evaluated as internal QC material for AMA-M2 detection. Remnant serum samples of primary biliary cirrhosis (PBC) patients requested for AMA-M2 were collected after test. The collected samples were pooled and homogenized. After heat-inactivation the pooled serum was divided in aliquots as internal QC material. The stability of the internal QC material and the precision of the AMA-M2 detecting system were evaluated, and a 20-day daily internal QC test was assessed. The quality of pooled serum was reliable, and the validity period could last for more than 16 months. The precision of AMA-M2 signal intensity detection was stable with a mean value 112.7 and coefficients of variation (CV) 9.7% in repetitive tests of one same sample, and a mean value 113.4 and CV 11.8% in different sample. Considering the 20-day daily internal QC evaluation period, the CV of the internal QC results was 8.1% which achieved the goal of internal quality control. The results suggest that the home-made AMA-M2 internal QC material was stable and reliable. The AMA-M2 signal intensity detection system has high precision. The home-made AMA-M2 internal quality control system has a good application value for its stability, precision, and cost effectiveness.
引用
收藏
页码:6038 / 6043
页数:6
相关论文
共 10 条
  • [1] Anti-mitochondrial M2 antibody-positive myositis may be an independent subtype of autoimmune myositis
    Nishimori, Yukako
    Tanboon, Jantima
    Oyama, Munenori
    Motegi, Haruhiko
    Tomo, Yui
    Oba, Mari
    Yamanaka, Ai
    Sugie, Kazuma
    Suzuki, Shigeaki
    Hayashi, Shinichiro
    Noguchi, Satoru
    Nishino, Ichizo
    JOURNAL OF NEUROLOGY, 2025, 272 (03)
  • [2] The accuracy of the anti-mitochondrial antibody and the M2 subtype test for diagnosis of primary biliary cirrhosis: a meta-analysis
    Hu, Shiling
    Zhao, Fengrong
    Wang, Qingsong
    Chen, Wei-Xian
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (11) : 1533 - 1542
  • [3] Screening of anti-mitochondrial antibody subtype M2 in residents at least 18 years of age in an urban district of Shanghai, China
    Chen, B. -H.
    Wang, Q. -Q.
    Zhang, W.
    Zhao, L. -Y.
    Wang, G. -Q.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2016, 20 (10) : 2052 - 2060
  • [4] Detection of serum M2 anti-mitochondrial antibodies by enzyme-linked immunosorbent assay is potentially less specific than by immunofluorescence
    Patel, D
    Egner, W
    Gleeson, D
    Wild, G
    Ward, A
    ANNALS OF CLINICAL BIOCHEMISTRY, 2002, 39 : 304 - 307
  • [5] A human mitochondrial DNA standard reference material for quality control in identification, medical diagnosis, and mutational detection.
    Levin, BC
    Chen, HY
    Reeder, DJ
    CLINICAL CHEMISTRY, 1996, 42 (11) : 22 - 22
  • [6] A human mitochondrial DNA standard reference material for quality control in forensic identification, medical diagnosis, and mutation detection
    Levin, BC
    Cheng, HY
    Reeder, DJ
    GENOMICS, 1999, 55 (02) : 135 - 146
  • [7] A human mitochondrial DNA standard deference material for quality control in mutation detection, medical diagnosis, and forensic identification.
    Levin, BC
    Cheng, H
    Reeder, DJ
    AMERICAN JOURNAL OF HUMAN GENETICS, 1997, 61 (04) : A392 - A392
  • [8] Development of an In Vitro Potency Assay System for Quality Control of Anti-Human Epidermal Growth Factor Receptor 2 Antibody Admixtures
    Hu, P. Lv Lide
    Yeh, J. Y.
    Gao, X.
    Liu, D.
    Wang, G.
    Liu, Y.
    INDIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2021, 83 (02) : 293 - 305
  • [9] Automated indirect immunofluorescence microscopy enables the implementation of a quantitative internal quality control system for anti-nuclear antibody (ANA) analysis
    Maenhout, Thomas M.
    Bonroy, Carolien
    Verfaillie, Charlotte
    Stove, Veronique
    Devreese, Katrien
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (07) : 989 - 998
  • [10] Detection of anti-VacA antibody responses in serum and gastric juice samples using type s1/m1 and s2/m2 Helicobacter pylori VacA antigens
    Perez-Perez, GI
    Peek, RM
    Atherton, JC
    Blaser, MJ
    Cover, TL
    CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 1999, 6 (04) : 489 - 493