The Use of Reverse Osmosis in the Removal of PAHs from Municipal Landfill Leachate

被引:46
|
作者
Smol, Marzena [1 ,2 ]
Wlodarczyk-Makula, Maria [3 ]
Mielczarek, Karolina [1 ]
Bohdziewicz, Jolanta [4 ]
Wloka, Dariusz [1 ]
机构
[1] Czestochowa Tech Univ, Inst Environm Engn, Czestochowa, Poland
[2] Polish Acad Sci, Mineral & Energy Econ Res Inst, PL-31261 Krakow, Poland
[3] Czestochowa Tech Univ, Dept Chem Water & Wastewater Technol, Czestochowa, Poland
[4] Silesian Tech Univ, Inst Water & Wastewater Engn, Gliwice, Poland
关键词
Membrane techniques; municipal landfill leachate; PAHs; reverse osmosis - RO; POLYCYCLIC AROMATIC-HYDROCARBONS; WASTE-WATER; SYSTEM; MICROPOLLUTANTS; PERFORMANCE; NITROGEN; ORGANICS;
D O I
10.1080/10406638.2014.957403
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
Polycyclic aromatic hydrocarbons (PAHs) are relatively well-known organic pollutants and due to their carcinogenic and mutagenic properties their presence in the environment still attracts a lot of attention.According to literature reports and own research, PAHs presence in wastewaters is common. It was confirmed that PAHs are the components of municipal landfill leachate. Membrane techniques are one of the most interesting ways of removing PAHs from leachate.The purpose of this article is to monitor PAHs concentration changes during the membrane (reverse osmosis - RO) leachate treatment processes. In the first stage of testing leachates were filtrated on the sand bed (pre-filtration). After the pre-filtration they were directed to the membrane module for the main filtration.Sixteen PAHs listed by EPA were analyzed. The results with information on PAHs concentration in leachate samples were presented using HPLC with fluorescence detection (FLD). The changes in PAHs concentration were determined in leachate samples before and after pre-filtration as well as after RO. The decrease of PAHs concentration in the samples was observed after these processes. The total concentration of 16 PAHs in raw municipal landfill leachates amounted to 23.64-26.95g/L. The research confirmed the high efficiency in removal of PAHs while using a reverse osmosis (59-72%). Including the pre-filtration, the overall level of removed PAHs reached 81-86%. The average PAHs concentration after pre-filtration and RO was in the 4.46-4.99g/L range. The municipal landfill leachate with a high concentration of PAHs should be cleaned before it is discharged into the environment.
引用
收藏
页码:20 / 39
页数:20
相关论文
共 50 条
  • [1] TREATMENT OF MUNICIPAL LANDFILL LEACHATE BY THE PROCESS OF REVERSE OSMOSIS AND EVAPORATION
    Sir, Marek
    Honzajkova, Zuzana
    FRESENIUS ENVIRONMENTAL BULLETIN, 2015, 24 (6A): : 2245 - 2250
  • [2] Boron removal from landfill leachate by means of nanofiltration and reverse osmosis
    Dydo, P
    Turek, M
    Ciba, J
    Trojanowska, J
    Kluczka, J
    DESALINATION, 2005, 185 (1-3) : 131 - 137
  • [3] Influence of pH in AOP on Humic Compounds Removal from Municipal Landfill Leachate Concentrate after Reverse Osmosis
    Koc-Jurczyk, Justyna
    Jurczyk, Lukasz
    JOURNAL OF ECOLOGICAL ENGINEERING, 2019, 20 (02): : 161 - 168
  • [4] Removal of organic and inorganic compounds from landfill leachate using reverse osmosis
    Talalaj, I. A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2015, 12 (09) : 2791 - 2800
  • [5] Removal of organic and inorganic compounds from landfill leachate using reverse osmosis
    I. A. Talalaj
    International Journal of Environmental Science and Technology, 2015, 12 : 2791 - 2800
  • [6] Treatment of landfill leachate by reverse osmosis
    Chianese, A
    Ranauro, R
    Verdone, N
    WATER RESEARCH, 1999, 33 (03) : 647 - 652
  • [7] Removal of nitrogen compounds from landfill leachate using reverse osmosis with leachate stabilization in a buffer tank
    Talalaj, Izabela Anna
    ENVIRONMENTAL TECHNOLOGY, 2015, 36 (09) : 1091 - 1097
  • [8] Stripping/flocculation/membrane bioreactor/reverse osmosis treatment of municipal landfill leachate
    Hasar, Halil
    Unsal, Sezahat A.
    Ipek, Ubeyde
    Karatas, Serdar
    Cinar, Ozer
    Yaman, Cevat
    Kinaci, Cumali
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 171 (1-3) : 309 - 317
  • [9] Nitrogen Removal from Municipal Landfill Leachate
    Ibrahimpasic, J.
    Dragicevic, T. Landeka
    Hren, M. Zanoski
    Bacun-Druzina, V.
    Curlin, M.
    Vrcek, I. Vinkovic
    CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2010, 24 (04) : 453 - 458
  • [10] Quality of Leachate From Landfill with Reverse Osmosis Concentrate Recirculation
    Talalaj, Izabela Anna
    JOURNAL OF ECOLOGICAL ENGINEERING, 2019, 20 (08): : 205 - 211