EDIPO: The Test Facility for High-Current High-Field HTS Superconductors

被引:18
|
作者
Bruzzone, P. [1 ]
Stepanov, B. [1 ]
Uglietti, D. [1 ]
Wesche, R. [1 ]
Sedlak, K. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Ctr Res Plasma Phys, Fus Technol Grp, CH-5232 Villigen, Switzerland
关键词
High-current superconducting cables; high magnetic field; high-temperature superconductors (HTSs); test facility; user interfaces; EFDA DIPOLE; DESIGN;
D O I
10.1109/TASC.2015.2501102
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The commissioning of the European DIPOle (EDIPO) test facility at the Center for Research in Plasma Physics in Villigen was completed in Spring 2015, and the first test of a 60-kA/12-T high-temperature superconductor (HTS) was carried out in June 2015. User specifications are issued to allow external users to prepare their own sample matching the interface of the test facility. EDIPO offers a background magnetic field up to 12.35 T in a rectangular test well with a cross section of 89 mm x 138 mm (sample dimension). The homogeneous high field length is 910 mm (+/- 1%) or 680 mm (+/- 0.5%) at full current. A set of small copper coils provides a superimposed ac field with amplitude up to +/- 0.3 T and frequency up to 1 Hz. A superconducting transformer provides steady-state operating current for the sample up to 100 kA. The cooling circuit of the sample supplies supercritical helium at 10-bar inlet pressure. The mass flow rate, which is adjustable by cryogenic valves, is up to 8 g/s in each branch of the sample at 4.5 K. The operating temperature ranges from 4.5 to 60 K (at high temperature, the range of mass flow rate is reduced). To test samples at temperature higher than 10 K, an HTS "adapter" connects the sample to the NbTi transformer plates, which must remain cold. In such case, the length of the sample is reduced from 3600 mm (typical low-temperature superconductor sample) to 2900 mm (HTS sample with adapter).
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [1] HIGH-FIELD, HIGH-CURRENT SUPERCONDUCTORS
    HULM, JK
    MATTHIAS, BT
    [J]. SCIENCE, 1980, 208 (4446) : 881 - 887
  • [2] Tl-based superconductors for high-current, high-field applications
    Jergel, M
    Gallardo, AC
    Guajardo, CF
    Strbik, V
    [J]. SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (06): : 427 - 446
  • [3] SYNTHETIC HIGH-FIELD, HIGH-CURRENT SUPERCONDUCTOR
    BEAN, CP
    DOYLE, MV
    PINCUS, AG
    [J]. PHYSICAL REVIEW LETTERS, 1962, 9 (03) : 93 - &
  • [4] THE ROLE OF GRAIN-BOUNDARIES IN DETERMINING JC IN HIGH-FIELD HIGH-CURRENT SUPERCONDUCTORS
    DEWHUGHES, D
    [J]. PHILOSOPHICAL MAGAZINE B-PHYSICS OF CONDENSED MATTER STATISTICAL MECHANICS ELECTRONIC OPTICAL AND MAGNETIC PROPERTIES, 1987, 55 (04): : 459 - 479
  • [5] Plan for testing high-current superconductors for fusion reactors with a 15 T test facility
    Imagawa, Shinsaku
    Obana, Tetsuhiro
    Takada, Suguru
    Hamaguchi, Shinji
    Chikaraishi, Hirotaka
    Yanagi, Nagato
    Takahata, Kazuya
    Iwamoto, Akifumi
    Yamada, Shuichi
    Mito, Toshiyuki
    [J]. Plasma and Fusion Research, 2015, 10 (SpecialIssue.2) : 1 - 4
  • [6] HIGH-FIELD MAGNETS AND HIGH-FIELD SUPERCONDUCTORS
    FONER, S
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1995, 5 (02) : 121 - 140
  • [7] DUCTILE, HIGH-FIELD, HIGH-CURRENT TERNARY SUPERCONDUCTING ALLOY
    ROSE, RM
    WULFF, J
    [J]. JOURNAL OF APPLIED PHYSICS, 1962, 33 (07) : 2394 - &
  • [8] Investigation of HTS Twisted Stacked-Tape Cable (TSTC) Conductor for High-Field, High-Current Fusion Magnets
    Takayasu, Makoto
    Chiesa, Luisa
    Noyes, Patrick D.
    Minervini, Joseph V.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [9] HIGH-FIELD SUPERCONDUCTORS
    HILLMANN, H
    [J]. LECTURE NOTES IN PHYSICS, 1983, 177 : 517 - 530
  • [10] TEST FACILITY FOR INVESTIGATIONS OF HIGH-CURRENT SUPERCONDUCTOR SAMPLES
    BURSIKOV, AS
    ZHELAMSKY, MV
    LANCETOV, AA
    LEBEDEV, AA
    MYMRIKOV, VV
    RODIN, IY
    TROKHACHEV, GV
    YAKUBOVSKY, VG
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1992, 28 (01) : 609 - 612