Real time three-dimensional transthoracic echocardiography for guiding Amplatzer septal occluder device deployment in patients with atrial septal defect

被引:50
|
作者
Chen, Fong L.
Hsiung, Ming C.
Hsieh, Kai S.
Li, Yi C.
Chou, Ming C.
机构
[1] Chung Shan Med Univ Hosp, Dept Pediat, Div Pediat Cardiol, Taichung, Taiwan
[2] Chung Shan Med Univ, Inst Med, Taichung, Taiwan
[3] Cheng Hsin Med Ctr, Dept Cardiol, Taipei, Taiwan
[4] Vet Gen Hosp Kaohsiung, Dept Pediat, Kaohsiung, Taiwan
[5] Chung Shan Med Univ Hosp, Dept Surg, Div Thorac Surg, Taichung, Taiwan
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2006年 / 23卷 / 09期
关键词
atrial septal defect; Amplatzer septal occluder; real time three-dimensional transthoracic echocardiography;
D O I
10.1111/j.1540-8175.2006.00322.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transcatheter Amplatzer septal occluder (ASO) device closure of atrial septal defects (ASDs) has traditionally been guided by two-dimensional transesophageal echocardiography (2D-TEE) and intracardiac echocardiography (ICE) modalities. Real time three-dimensional transthoracic echocardiography (RT3D-TTE) provides rotating images to define ASD and adjacent structures with potential as an alternative to 2D-TEE or ICE for guiding the device closure of ASD. Our aim was to assess the feasibility and effectiveness of RT3D-TTE in parasternal four-chamber views to guide ASO device closure of ASD. Methods and Results: From July 2004 to August 2005, 59 patients underwent transcatheter ASO device closure of ASD. The first 30 patients underwent 2D-TEE guidance under general anesthesia and the remaining 29 patients underwent RT3D-TTE guidance with local anesthesia. All interventions were successfully completed without complications. The clinical characteristics and transcatheter closure variables of RT3D-TTE and 2D-TEE were compared. Echocardiographic visualization of ASD and ASO deployment was found to be adequate when using either methods. Catheterization laboratory time (39.1 +/- 5.4 vs 78.8 +/- 14.1 minutes, P < 0.001) and interventional procedure length (7.6 +/- 4.2 vs 15.3 +/- 2.9 minutes, P < 0.001) were shortened by using RT3D-TTE as compared with 2DE-TEE. There was no difference in the rate of closure following either method, assessed after a 6-month follow-up. The maximal diameter measured by RT3D-TTE and 2D-TEE was correlated well with a balloon-stretched ASD size (y = 0.985x + 0.628, r = 0.924 vs y = 0.93x + 2.08, r = 0.885, respectively). Conclusion: RT3D-TTE may be a feasible, safe, and effective alternative to the standard practice of using 2D-TEE to guide ASO deployment.
引用
收藏
页码:763 / 770
页数:8
相关论文
共 50 条
  • [1] Real-time 3D transoesophageal echocardiography for guiding Amplatzer septal occluder device deployment in an adult patient with atrial septal defect
    Acar, Philippe
    Massabuau, Pierre
    Elbaz, Meyer
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2008, 9 (06): : 822 - 823
  • [2] Preprocedural Transthoracic Echocardiography Can Predict Amplatzer Septal Occluder Device Size for Transcatheter Atrial Septal Defect Closure
    Sah, Serena P.
    Bartakian, Sergio
    El-Said, Howaida
    Molkara, Delaram P.
    Printz, Beth
    Moore, John W.
    CONGENITAL HEART DISEASE, 2016, 11 (06) : 656 - 662
  • [3] On-line intracardiac echocardiography alone for Amplatzer Septal Occluder selection and device deployment in adult patients with atrial septal defect
    Zanchetta, N
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2004, 95 (01) : 61 - 68
  • [4] Amplatzer Septal Occluder Closure of Atrial Septal Defect: Evaluation of Transthoracic Echocardiography, Cardiac CT, and Transesophageal Echocardiography
    Ko, Sheung-Fat
    Liang, Chi-Di
    Yip, Hon-Kan
    Huang, Chung-Cheng
    Ng, Shu-Hang
    Huang, Chien-Fu
    Chen, Min-Chi
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) : 1522 - 1529
  • [5] Reliability of transthoracic echocardiography in estimating the size of Amplatzer septal occluder and guiding percutaneous closure of atrial septal defects
    LI GuishuangKONG GuangmingJI QiushangLI JifuCHEN YuguoYOU Beian and ZHANG Yun Key Laboratory of Cardiovascular Remodeling and Function ResearchChinese Ministry of Education and Chinese Ministry of Health Department of Emergency Medicine
    Department of Geriatrics Qilu HospitalShandong UniversityJinanShandong China
    中华医学杂志(英文版), 2008, (11) : 973 - 976
  • [6] Reliability of transthoracic echocardiography in estimating the size of Amplatzer septal occluder and guiding percutaneous closure of atrial septal defects
    Li Gui-shuang
    Kong Guang-ming
    Ji Qiu-shang
    Li Ji-fu
    Chen Yu-guo
    You Bei-an
    Zhang Yun
    CHINESE MEDICAL JOURNAL, 2008, 121 (11) : 973 - 976
  • [7] The Amplatzer® Septal Occluder, a transcatheter device for atrial septal defect closure
    Fu, Yun-Ching
    Hijazi, Ziyad M.
    EXPERT REVIEW OF MEDICAL DEVICES, 2008, 5 (01) : 25 - 31
  • [8] Comparison of two- and three-dimensional transesophageal echocardiography in patients undergoing atrial septal closure with the amplatzer septal occluder
    Tamborini, G
    Pepi, M
    Susini, F
    Trabattoni, D
    Maltagliati, A
    Berna, G
    Onorato, E
    Bartorelli, AL
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (09): : 1025 - +
  • [9] Embolization of Atrial Septal Occluder Device into the Pulmonary Artery: A Rare Complication and Usefulness of Live/Real Time Three-Dimensional Transthoracic Echocardiography
    Dod, Harvinder S.
    Reddy, Venkataramana K.
    Bhardwaj, Ravindra
    Gudausky, Todd
    Warden, Bradford E.
    Beto, Robert J.
    Nanda, Navin C.
    Jain, Abnash C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (06): : 739 - 741
  • [10] Comparison of the Occlutech® Figulla® Septal Occluder and Amplatzer® Septal Occluder for Atrial Septal Defect Device Closure
    Supaporn Roymanee
    Worakan Promphan
    Nakharin Tonklang
    Kanjarut Wongwaitaweewong
    Pediatric Cardiology, 2015, 36 : 935 - 941