Microtensile bond strength analysis of adhesive systems to Er:YAG and Er,Cr:YSGG laser-treated dentin

被引:30
|
作者
Ramos, Thaysa Monteiro [1 ]
Ramos-Oliveira, Thayanne Monteiro [1 ]
Moretto, Simone Goncalves [1 ]
de Freitas, Patricia Moreira [1 ]
Esteves-Oliveira, Marcella [2 ]
Eduardo, Carlos de Paula [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Restorat Dent, Special Lab Lasers Dent LELO, BR-05508000 Sao Paulo, Brazil
[2] Rhein Westfal TH Aachen, Dept Operat Dent Periodontol & Prevent Dent ZPP, D-52074 Aachen, Germany
基金
巴西圣保罗研究基金会;
关键词
Dentin; Er:YAG laser; Er; Cr:YSGG laser; SEM; Microtensile bond strength; ER-YAG-LASER; SELF-ETCHING PRIMER; BUR-CUT; CAVITY PREPARATION; WATER STORAGE; SURFACE; RESIN; ACID; ENAMEL; MICROLEAKAGE;
D O I
10.1007/s10103-012-1261-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this in vitro study was to evaluate the effect of different surface treatments (control, diamond bur, erbium-doped yttrium aluminum garnet (Er:YAG) laser, and erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser) on sound dentin surface morphology and on microtensile bond strength (mu TBS). Sixteen dentin fragments were randomly divided into four groups (n = 4), and different surface treatments were analyzed by scanning electron microscopy. Ninety-six third molars were randomly divided into eight groups (n = 12) according to type of surface treatment and adhesive system: G1 = Control + Clearfil SE Bond (SE); G2 = Control + Single Bond (SB); G3 = diamond bur (DB) + SE; G4 = DB + SB, G5 = Er:YAG laser (2.94 mu m, 60 mJ, 2 Hz, 0.12 W, 19.3 J/cm(2)) + SE; G6 = Er:YAG + SB, G7 = Er,Cr:YSGG laser (2.78 mu m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm(2)) + SE; and G8 = Er,Cr:YSGG + SB. Composite blocks were bonded to the samples, and after 24-h storage in distilled/deionized water (37 A degrees C), stick-shaped samples were obtained and submitted to mu TBS test. Bond strength values (in megapascal) were analyzed by two-way ANOVA and Tukey tests (alpha = 0.05). G1 (54.69 A +/- 7.8 MPa) showed the highest mean, which was statistically significantly higher than all the other groups (p < 0.05). For all treatments, SE showed higher bond strength than SB, except only for Er,Cr:YSGG treatment, in which the systems did not differ statistically from each other. Based on the irradiation parameters considered in this study, it can be concluded that Er:YAG and Er,Cr:YSGG irradiation presented lower values than the control group; however, their association with self-etching adhesive does not have a significantly negative effect on sound dentin (mu TBS values of > 20 MPa).
引用
收藏
页码:565 / 573
页数:9
相关论文
共 50 条
  • [1] Microtensile bond strength analysis of adhesive systems to Er:YAG and Er,Cr:YSGG laser-treated dentin
    Thaysa Monteiro Ramos
    Thayanne Monteiro Ramos-Oliveira
    Simone Gonçalves Moretto
    Patricia Moreira de Freitas
    Marcella Esteves-Oliveira
    Carlos de Paula Eduardo
    Lasers in Medical Science, 2014, 29 : 565 - 573
  • [2] Bond strength of adhesive restorations to Er:YAG laser-treated dentin
    Malta, D. A. M. P.
    Kreidler, M. A. M.
    Villa, G. E.
    de Andrade, M. F.
    Fontana, C. R.
    Lizarelli, R. F. Z.
    LASER PHYSICS LETTERS, 2007, 4 (02) : 153 - 156
  • [3] Microtensile bond strength of different adhesive systems in dentin irradiated with Er:YAG laser
    Sierpinsky, L. M. G.
    Lima, D. M.
    Candido, M. S. M.
    Bagnato, V. S.
    Porto-Neto, S. T.
    LASER PHYSICS LETTERS, 2008, 5 (07) : 547 - 551
  • [4] Effects of Er:YAG and Er,Cr:YSGG laser irradiation and adhesive systems on microtensile bond strength of a self-adhering composite
    Kaptan, Alper
    Oznurhan, Fatih
    LASERS IN MEDICAL SCIENCE, 2023, 38 (01)
  • [5] Effects of Er:YAG and Er,Cr:YSGG laser irradiation and adhesive systems on microtensile bond strength of a self-adhering composite
    Alper Kaptan
    Fatih Oznurhan
    Lasers in Medical Science, 38
  • [6] Bond Strength of Adhesive Systems to Er, Cr:YSGG Laser-Irradiated Dentin
    Carvalho, Adriana Oliveira
    Reis, Andre Figueiredo
    de Oliveira, Marcelo Tavares
    de Freitas, Patricia Moreira
    Correa Aranha, Ana Cecilia
    Eduardo, Carlos de Paula
    Giannini, Marcelo
    PHOTOMEDICINE AND LASER SURGERY, 2011, 29 (11) : 747 - 752
  • [7] Influence of Er,Cr:YSGG laser treatment on the microtensile bond strength of adhesives to dentin
    Cardoso, Marcio Vivan
    Coutinho, Eduardo
    Ermis, R. Banu
    Poitevin, Andre
    Van Landuyt, Kirsten
    De Munck, Jan
    Carvalho, Rubens C. R.
    Lambrechts, Paul
    Van Meerbeek, Bart
    JOURNAL OF ADHESIVE DENTISTRY, 2008, 10 (01): : 25 - 33
  • [8] Adhesive Bond Strength of Er Cr YSGG Laser Treated Deciduous Dentin to Resin Cements
    Kattan, Hiba Faisal
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (02): : 383 - 388
  • [9] Effect of an Er,Cr:YSGG laser preparation on dentin bond strength of a universal adhesive
    Yazici, A. Ruya
    Karaman, Emel
    Tuncer, Duygu
    Berk, Gizem
    Ertan, Atilla
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2016, 30 (22) : 2477 - 2484
  • [10] Microtensile bond strength of resin composite to dentin treated with Er:YAG laser of bleached teeth
    Eduardo dos Santos Leonetti
    José Augusto Rodrigues
    André Figueiredo Reis
    Ricardo Scarparo Navarro
    Ana Cecília Correa Aranha
    Alessandra Cassoni
    Lasers in Medical Science, 2012, 27 : 31 - 38