An Application of Brightness Temperature Received from a Ground-based Microwave Radiometer to Estimation of Precipitation Occurrences and Rainfall Intensity

被引:2
|
作者
Won, Hye Young [1 ]
Kim, Yeon-Hee [1 ]
Lee, Hee-Sang [1 ]
机构
[1] KMA, Natl Inst Meteorol Res, Forecast Res Lab, Seoul 156720, South Korea
关键词
Microwave radiometer (MWR); brightness temperature (TB); precipitation occurrences; rainfall intensity; KEOP; ATMOSPHERIC BOUNDARY-LAYER; WATER-VAPOR; CLOUD LIQUID; VALIDATION;
D O I
暂无
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Ground-based microwave radiometers (MWR) provide continuous thermodynamic ( temperature, water vapor, and cloud liquid) soundings in the clear and cloudy weather conditions. These profiles can be determined by observing the intensity of the atmospheric radiation at selected frequencies. The MWR used in this study is TP/WVP-3000A, which measures the intensity of radiation at 8 water vapor channels (22-30 GHz) and 14 oxygen channels (51-59 GHz) to obtain thermodynamic profiles at National Center for Intensive Observation of severe weather (NCIO) located at Haenam, Korea. In this study, the predictability of precipitation occurrences and the estimation of rainfall intensity were investigated by using the brightness temperature (TB) of the MWR. The averaged differences of TBs in 2 hours before raining were calculated and compared with those of period unrelated with rain. In 2 hours before raining, the pronounced increase of TB was observed in water vapor channels (22-30 GHz), while TBs in 54-59 GHz as oxygen channels were almost remaining constant except for the great increase of TB at 51-52 GHz related to cloud liquid water. Performance for forecasts of precipitation occurrences using the preceding increases of TBs at 22.2 GHz, 30.0 GHz, and 51.2 GHz was improved and better than the 3-hour operational ( routine) forecasts. The estimation of rainfall intensity was examined by two simple estimative methods using the linear and the nonlinear regression analyses between rainfall intensity and TBs. Rainfall intensity was estimated by the calculated regression curves of TBs from MWR and compared with observed one by an Optical Rain Gauge (ORG) at the Haenam NCIO. As a result of the verification on forecasting performances, both the linear and the logarithmic regression methods between the observed and the estimated rainfall intensity showed substantially high in Equitable Threat Scores (ETSs) and correlation coefficients.
引用
收藏
页码:55 / 69
页数:15
相关论文
共 50 条
  • [1] Evaluation of brightness temperature from a forward model of ground-based microwave radiometer
    Rambabu, S.
    Pillai, J. S.
    Agarwal, A.
    Pandithurai, G.
    [J]. JOURNAL OF EARTH SYSTEM SCIENCE, 2014, 123 (04) : 641 - 650
  • [2] Evaluation of brightness temperature from a forward model of ground-based microwave radiometer
    S Rambabu
    J S Pillai
    A Agarwal
    G Pandithurai
    [J]. Journal of Earth System Science, 2014, 123 : 641 - 650
  • [3] Thunderstorm Nowcasting Using Ground-Based Microwave Radiometer Brightness Temperature Measurements
    R. Pushpa Saroja
    M. Rajasekhar
    C. V. Naidu
    S. Rambabu
    G. Paparao
    C. Deepak
    [J]. Journal of the Indian Society of Remote Sensing, 2023, 51 : 2285 - 2294
  • [4] Thunderstorm Nowcasting Using Ground-Based Microwave Radiometer Brightness Temperature Measurements
    Saroja, R. Pushpa
    Rajasekhar, M.
    Naidu, C. V.
    Rambabu, S.
    Paparao, G.
    Deepak, C.
    [J]. JOURNAL OF THE INDIAN SOCIETY OF REMOTE SENSING, 2023, 51 (11) : 2285 - 2294
  • [5] Measurement of Solar Absolute Brightness Temperature Using a Ground-Based Multichannel Microwave Radiometer
    Lei, Lianfa
    Wang, Zhenhui
    Ma, Yingying
    Zhu, Lei
    Qin, Jiang
    Chen, Rui
    Lu, Jianping
    [J]. REMOTE SENSING, 2021, 13 (15)
  • [6] Rainfall intensity estimation by ground-based dual-frequency microwave radiometers
    Liu, GR
    Liu, CC
    Kuo, TH
    [J]. JOURNAL OF APPLIED METEOROLOGY, 2001, 40 (06): : 1035 - 1041
  • [7] Assimilation of Ground-Based Microwave Radiometer on Heavy Rainfall Forecast in Beijing
    Qi, Yajie
    Fan, Shuiyong
    Li, Bai
    Mao, Jiajia
    Lin, Dawei
    [J]. ATMOSPHERE, 2022, 13 (01)
  • [8] Ground-Based Microwave Radiometer Profiler Observations before a Heavy Rainfall
    Xu, Wenjing
    Liu, Hongyan
    [J]. APPLIED MECHANICS AND CIVIL ENGINEERING, 2012, 137 : 312 - +
  • [9] Analysis on the solar influence to brightness temperatures observed with a ground-based microwave radiometer*
    Pan, Yun
    Lei, Lianfa
    Li, Qing
    Jiang, Sulin
    Wang, Zhenhui
    [J]. JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2021, 222
  • [10] Improving the Retrieval of Cloudy Atmospheric Profiles from Brightness Temperatures Observed with a Ground-Based Microwave Radiometer
    Li, Qing
    Wei, Ming
    Wang, Zhenhui
    Jiang, Sulin
    Chu, Yanli
    [J]. ATMOSPHERE, 2021, 12 (05)